Air Conditioner

Operating Instructions

Forced operation

Forced operation is used when the remote controller can't be used. The operation will be started if the ON/OFF
button is pressed. If you want to stop the operation, re-press the button.

ON/OFF

button

Heat pump Model

Cooling Model

Room Temp. 

24°C

21°C 

Room Temp. < 24°C

Room Temp. < 21°C

Operating mode

Cooling

Cooling

Healthy Dehumidification

Heating

Indoor FAN Speed

High

High

High

High

Setting Temperature

22°C

22°C

23°C

24°C

Test operation

During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room temperature
and resets in 18 minutes. During test operation, if remote controller signal is received, the unit operates as remote controller
sets. If you want to use this operation, Press and hold the ON/OFF button for 3~5 seconds, then the buzzer sound 1
'beep'. If you want to stop the operation, re-press the button.

This feature is enabled by factory default setting, but you can disable it by pressing the ON/OFF button for 6
seconds. The unit will beep twice and the lamp will blink 6 times. 
To enable it, press the button again for 6 seconds. The unit will beep twice and the blue lamp will blink 4 times.

NOTE

This function is useful in the situation of power failure. 
When power regains after a failure this feature restore the previous operating condition 
and the air conditioner will run in the same settings.

Auto Restart Function

ON/OFF

button

Содержание V10CRH-N

Страница 1: ...www lgservice com IMPORTANT Please read this owner s manual carefully and thoroughly before installing and operating your room air conditioner Please retain this owner s manual for future reference after reading it thoroughly Type Wall Mounted ...

Страница 2: ...upervised to ensure that they do not play with the air conditioner When the power cord is to be replaced replacement work shall be performed by authorized personnel only using only genuine replacement parts A Safety Precautions 3 B Electrical Safety 6 Temporary Use of an Adapter 6 Temporary Use of an Extension Cord 6 Symbols used in this Manual 6 C Product Introduction 7 Indoor Units 7 Operation I...

Страница 3: ...y There is risk of fire or electric shock due to dust water etc Use the correctly rated breaker or fuse There is risk of fire or electric shock Do not modify or extend the power cable If the power cable or cord has scrathes or skin peeled off or deteriorated then it must be replaced There is risk of fire or electric shock For installation removal or reinstall always contact the dealer or an Author...

Страница 4: ...ilure If strange sound smell or smoke comes from product Immediately turn the breaker off or disconnect the power supply cable There is risk of electric shock or fire Ventilate the product room from time to time when operating it together with a stove or heating element etc Oxygen deficiency can occur and hence harm your health Turn the main power off and unplug the unit when cleaning or repairing...

Страница 5: ... in the system If air enters the refrigerant system an excessively high pressure results causing equipment damage or injury If the refrigerant gas leaks during the installation ventilate the area immediately Otherwise it can be harmfull for your health Dismantling the unit treatment of the refrigerant oil and eventual parts should be done in accordance with local and national standards Replace the...

Страница 6: ...nuine adapter available from most local hardware stores Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection To disconnect the power cord from the adapter use one hand on each to avoid damaging the ground terminal Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage Never use the applia...

Страница 7: ... non Inverter Model Lights up during timer operation or sleep mode auto operation Inverter Model only Defrost mode Power Display Indicates the setting temperature and operation mode Lights up during defrost mode or hot start operation Heat pump model only Lights up during outdoor unit operation Cooling model only Outdoor unit operation OUT DOOR Hot start operation Stops the indoor fan in heating o...

Страница 8: ...ording to the arrow direction 2 Insert new batteries making sure that the and of battery are installed correctly 3 Reattach the cover by sliding it back into position 1 Always use replace both batteries of same type 2 If the system is not to be used for a long time remove the batteries to save their working life 3 If the display screen of remote controller starts fading replace both of the batteri...

Страница 9: ...ep mode auto operation 11 ENERGY SAVING COOLING MODE BUTTON Used to set energy saving cooling mode operation 12 ROOM TEMPERATURE CHECKING BUTTON Used to check the room temperature 13 PLASMA BUTTON OPTIONAL Used to start or stop the plasma purification function Only air circulation in the room 1 Turn off indoor with remote control 2 Press plasma button Then fan will start 3 Remote fan speed with fa...

Страница 10: ...hangeover Heat Pump Model For cooling or heating operation set the desired indoor temperature by pressing the ROOM TEMPERATURE SETTING BUTTONS For cooling the temperature can be set within 18 C 30 C and for heating the temperature range is 16 C 30 C Set the fan speed with the remote controller You can select the fan speed in four steps low medium high and CHAOS by pressing the INDOOR FAN SPEED SEL...

Страница 11: ...n this operation If the system is not operating as desired switch manually to another mode To run the auto operation follow steps 1 and 2 See operation mode Auto Operation During Healthy Dehumidification Operation If you select the dehumidification mode on the OPERATION MODE SELECTION BUTTON the product starts to run the dehumidification function It automatically sets the room temperature and airf...

Страница 12: ...idification operation can be removed 1 Press the AUTO CLEAN BUTTON to activate this function 2 Now whenever the unit is turned off the indoor fan is still running for about 30 minutes internally without cooling or dehumidification operation Also the louver is closed 3 This dries up any remains of moisture cleans the unit internally 4 If you press AUTO CLEAN BUTTON again during operation this funct...

Страница 13: ...nosity The Display Luminosity can be adjusted by using the remote control Press the start stop button to start the unit Open the door on the remote control press the 2ndF button and press display luminosity button Display will be dark Press the button again to set bright display 1 Time can be set only when you press the RESET BUTTON Having replacing the batteries you should press the RESET BUTTON ...

Страница 14: ... hour increments by pressing the SLEEP MODE AUTO BUTTON 1 to 7 times The sleep mode is available for 1 to 7 times To alter the time period in steps of 1 hour press the SLEEP MODE AUTO BUTTON while aiming at air conditioner 3 In case of non Inverter Model Make sure the sleep mode LED lights up To cancel the sleep mode press the SLEEP MODE AUTO BUTTON several times until the sleep mode LED lights of...

Страница 15: ... unit 2 Press AUTO SWING BUTTON 3 The louvers will swing up down automatically 4 To stop the louver at a desired angle press again 5 Press button 6 Press AUTO SWING BUTTON Each time the button is pressed the air flow direction is changed in the direction of the arrow Press the AUTO SWING BUTTON once more 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step Horizontal Vane Control ...

Страница 16: ...djusted by using the remote controller 1 Press the START STOP BUTTON to start the unit 2 Press the VERTICAL LOUVER BUTTON 3 The louvers will swing left right automatically 4 To stop the louver at a desired angle press again 5 Press button 6 Press the VERTICAL LOUVER DIRECTION BUTTON Each time the button is pressed the air flow direction is changed in the direction of the arrow Press the VERTICAL L...

Страница 17: ...ed and 30 C setting temperature for 60 minutes You can activate this operation by pressing the JET COOL BUTTON To change from jet cool mode to high fan speed cooling mode press the JET COOL BUTTON or INIDOOR FAN SPEED SELECTOR BUTTON or the ROOM TERPERATURE SETTING BUTTON again Jet cool function cannot be activated during heating or auto changeover operations In case of Inverter Art Cool and Art C...

Страница 18: ...n 18 minutes During test operation if remote controller signal is received the unit operates as remote controller sets If you want to use this operation Press and hold the ON OFF button for 3 5 seconds then the buzzer sound 1 beep If you want to stop the operation re press the button This feature is enabled by factory default setting but you can disable it by pressing the ON OFF button for 6 secon...

Страница 19: ...detergent in luke warm water Dry well in shade after washing and reinstall the filters back in place Plasma Filter The plasma filters behind the air filter should be checked and cleaned once in every 3 months or more often if necessary To remove the filters see the self explanatory diagrams for each model type Clean the filters with a vacuum cleaner If it is dirty wash it with water and dry well i...

Страница 20: ...Then pull the filter tab slightly forward to remove the air filter After removing the air filter remove the plasma and Allergy Free Filter by slightly pulling downwards Plasma filter Don t touch this plasma filter within 10 seconds after opening the inlet grille it may cause an electric shock ...

Страница 21: ... good for the health and wastes electricity Keep blinds or curtains closed Do not let direct sunshine enter the room when the air conditioner is in operation Keep the room temperature uniform Adjust the vertical and horizontal airflow direction to ensure a uniform temperature in the room Make sure that the doors and windows are shut thight Avoid opening doors and windows as much as possible to kee...

Страница 22: ...ircuit Breaker will trip Make sure there are no curtains blinds or furniture blocking the front of the air conditioner Clean the filter at least every 2 weeks See the Maintenance and Service section When the air conditioner is first turned on you need to allow time for the room to cool down Check for open furnace floor registers and cold air returns Make sure they are correct Check and remove such...

Страница 23: ...P No MFL41549820 Printed in Thailand ...