Piping length and the elevation
Installation Manual 33
ENGLISH
Piping length and the elevation
Oil trap
Gas piping
Liquid piping
Outdoor unit
Outdoor unit
Indoor unit
Indoor unit
*15m
* Install trap at each
difference in height
15m
A trap is not necessary when the
outdoor unit is installed in a higher
position than the indoor unit.
Single Operation
UU21WH
5/8"(15.88mm)
3/8"(9.52mm)
10
50
5
30
40
UU24WH
Model
*Additional
refrigerant
(g/m)
Pipe Size
(Diameter:Ø)
Length A(m)
Elevation B(m)
Gas
Liquid
Standard
Max.
Standard
Max.
Precautions when laying power wiring
Use round pressure terminals for connections to the power terminal block.
When none are available, follow the instructions below.
• Do not connect wiring of different thicknesses to the power terminal block. (Slack in the power
wiring may cause abnormal heat.)
• When connecting wiring which is the same thickness, do as shown in the figure below.
W
ARNING:
Make sure that the screws of the terminal are free from looseness.
Round pressure terminal
Power wire
Содержание UU21WH
Страница 34: ...34 Air Conditioner Memo ...