Electronic parts Troubleshooting Guide
Is the unit operating?
Is the output
voltage of Micom's 10PIN on
the MAIN PCB 5V?
Is the "Power relay" for
indoor motor OK?
Check the indoor motor.
1. Press power ON/OFF button.
2. Reconnect the power supply.
Is the voltage
between 1PIN of CN8 and
NEUTRAL 220V?
1. Check or exchange IC01D,
IC02D on the main PCB.
1. Check or exchange RY10.
1. Check the wiring of
"Power relay".
2. Exchange "Power relay".
YES
YES
YES
NO
NO
NO
YES
NO
Is the compressor operating?
1. Check wiring for outdoor
motor and magnetic contactor.
2. Check outdoor motor & capacitor.
Is it cooling operation?
1. Press power "ON/OFF" button.
2. Select cooling operation.
1. Set following.
Set temp. < Room temp.
2. Wait, if the unit has operating
with 3-minute time delay.
YES
NO
YES
NO
Possible trouble 8
: Indoor motor does not operate.
Possible trouble 9
: Outdoor motor does not operate.
23
Содержание TN-C090BT00
Страница 1: ...Ducted Split Air Conditioner SERVICE MANUAL MODELS TN C090BT00 TN C120BT00 TN C180BT00 TN C240BT00 ...
Страница 11: ...Model No TN C180BT00 11 Wiring Diagrams ...
Страница 12: ...Model No TN C240 T00 B MEZ62337701 12 Wiring Diagrams ...
Страница 24: ...Features of Controller 1 Main Controller Circuit Diagram 24 ...
Страница 25: ...2 Feature of Main Controller 25 Model No TN C0 0BT00 9 TN C120BT00 ...
Страница 26: ...Model No TN C 0BT00 TN C 0BT00 18 4 2 26 ...
Страница 27: ...3 Feature of Remote Controller PCB ASS Y 4 Feature of Remote Controller LCD 27 ...
Страница 33: ...Exploded View and Replacement Parts List 559010 346811 566001 554030B 554160A 554030A 268711 ...
Страница 34: ...Exploded View and Replacement Parts List 346811 566001 554160A 559010 554030B 554030A 268711 ...
Страница 35: ...Memo 26 ...
Страница 36: ...Memo 27 ...
Страница 37: ...P No 3828A25001C JULY 2007 Printed in CHINA ...