INSTALLATION
ENGLISH
Select installation location considering following conditions to avoid bad condition when
additionally performing defrost operation.
- Install the outdoor unit at a place well ventilated and having a lot of sunshine in case of installing
the product at a place with a high humidity in winter (near beach, coast, lake, etc).
(Ex) Rooftop where sunshine always shines.
- Performance of heating will be reduced and preheat time of the indoor unit may be lengthened
in case of installing the outdoor unit in winter at following location:
- Shade position with a narrow space
- Location with much moisture in neighboring floor.
- Location with much humidity around.
- Location where ventilation is good.
It is recommended to install the outdoor unit at a place with a lot of sunshine as possible as.
- Location where water gathers since the floor is not even.
When installing the outdoor unit in a place that is constantly exposed to a strong wind like
a coast or on a high story of a building, secure a normal fan operation by using a duct or a
wind shield.
- Install the unit so that its discharge port faces to the wall of the building.
Keep a distance 500 mm or more between the unit and the wall surface.
- Supposing the wind direction during the operation season of the air conditioner, install the unit
so that the discharge port is set at right angle to the wind direction.
Air inlet grille
500
Strong
wind
Strong
wind
Blown
air