System Set-Up
54
Air-to-Water Heat Pump
Temperature range setting
• Function Code 13
: Setting air temperature in heating mode
Determine heating setting temperature range when air temperature is selected as setting
temperature.
NOTICE
• Function Code 14
: Setting leaving water temperature in heating mode
Determine heating setting temperature range when leaving water temperature is selected as
setting temperature.
• Function Code 15
: Setting sanitary tank leaving water temperature
Determine heating setting temperature range of water tank leaving water.
Only available when sanitary water tank feature is installed.
• Sanitary water tank and sanitary water tank kit should be installed.
• DIP switch No. 2 and 3 should be set properly.
• Function Code 18
: Screed drying mode.
After installing water pipes for under floor heating, user can select screed drying mode for curing the
cement.
Only available when remote air temperature sensor is connected.
• Accessory PQRSTA0 should be installed.
• Also, Function Code 03 should be set properly.
CAUTION
NOTICE