- 12 -
14) Set Brightness and Contrast to Max position.
15) Set SUB-CONTRAST 127(7F) (decimal) position.
16) Set B-DRIVE to 90(5A) at DRIVE of the alignment
program.
17-1) Adjust R-DRIVE and G-DRIVE command to white
balance x=0.283
±0.003 and y=0.298±0.003 on the
White Balance Meter with PC arrow keys.
17-2) Display color 15,0 window pattern (70x70mm) at mode 4.
18) Adjust SUB-CONTRAST command to 50
±2FL .
19) After push the “ENTER” key.
20) Display color 15,0 full white patten at Mode 4..
21) COLOR ADJ.
→
LUMINANCE
→
ABL command.
22) Adjust ABL to 32
±1FL of the luminance.
23) After push the “ENTER” key, and “COMMAND
→
PRESET EXIT
→
Y(Yes)” command.
24) Exit from the program.
5. Input EDID Data.
1) Display color 15,0 cross hatch pattern at Mode 4.
2) EEPROM
→
Write EDID command and confirm
“EDID Write OK!!” message of monitor.
3) Exit from the alignment program.
4) Power switch OFF/ON for EDID data save.
6. Adjustment for Focus.
1) Set the Brightness and Contrast to max position.
2) Display H character in full screen at Mode 4.
3) Adjust two Focus control on the FBT that focus
should be the best condition.