background image

www.lg.com

OWNER’S MANUAL

Please read this manual carefully before operating
your set and retain it for future reference.

AIR

CONDITIONER

The equipment complies with requirements of the Technical Regulation,
in terms of restrictions for the use of certain dangerous substances in
electrical and electronic equipment.

MODELS: 

WALL MOUNTED

K07EHC  

NTE1

  K07EHC  

UTE1  

K09EHC  

NTE1

  K09EHC  

UTE1

K12EHC  

NTE1

  K12EHC  

UTE1 

ENGLISH

O

ZBEK TILI

SRPSKI

РУССКИЙ ЯЗЫК

УКРАÏНСЬКА

ҚАЗАҚ ТІЛІ

БЕЛАРУСКАЯ МОВА

Содержание SS-H106TEA1 AOSANMC

Страница 1: ...equipment complies with requirements of the Technical Regulation in terms of restrictions for the use of certain dangerous substances in electrical and electronic equipment MODELS WALL MOUNTED K07EHC NTE1 K07EHC UTE1 K09EHC NTE1 K09EHC UTE1 K12EHC NTE1 K12EHC UTE1 ENGLISH O ZBEK TILI SRPSKI РУССКИЙ ЯЗЫК УКРАÏНСЬКА ҚАЗАҚ ТІЛІ БЕЛАРУСКАЯ МОВА ...

Страница 2: ...ow vertically or horizontally to circulate indoor air Speed up the fan to cool or warm indoor air quickly in a short period of time Open windows regularly for ventilation as the indoor air quality may deteriorate if the air conditioner is used for many hours Clean the Air filter once every 2 weeks Dust and impurities collected in the Air filter may block the air flow or weaken the cooling dehumidi...

Страница 3: ... safety Children should be supervised to ensure that they do not play with the appliance When the power cord is to be replaced replacement work shall ve performed by authorized personnel only using only genuine replacement parts Installation Use a standard circuit breaker and fuse conforming with the rating of the air conditioner Fail ure to do so may result in electric shock or product failure Co...

Страница 4: ...for an extended period of time in a small place without ventilation Ventilate the place regularly Failure to do so may result in explosion or fire When there is a gas leak ventilate sufficiently before using the air conditioner again Failure to do so may result in explosion or fire Unplug the power plug if there is a noise smell or smoke coming from the air conditioner Failure to do so may result ...

Страница 5: ...ditioner or spray water Use a smooth cloth It may result in serious injury or product failure Never touch the metal parts of the air conditioner when you remove the Air filter It may result in se rious injury or product failure Do not place any objects on the air conditioner It may result in product failure Always insert the filter securely after cleaning Clean the filter every two weeks or more o...

Страница 6: ...wdirection 12 Turning on the air conditionerautomati cally at a set time 12 Turning off the air conditioner automatically at a set time 12 Setting sleep mode 13 ADVANCED FUNCTIONS 13 Operating the air conditioner without the remote control 13 Restarting the air conditioner automatically 14 MAINTENANCE 15 Cleaning the Air filter 15 Cleaning the carbon filter 16 TROUBLESHOOTING 16 Self diagnosis fun...

Страница 7: ...ront grille NOTE The number of operation lamps and their locations may vary depending on the model of the air conditioner 7 BEFORE USE ENGLISH Indoor unit Please keep the protective film of reset switch It is used to protect the PCB from ESD damage The feature can be changed according to type of model The feature can be changed according to type of model BEFORE USE Components ...

Страница 8: ...ment buttons Increase the temperature or time by 1 unit Decrease the temperature or time by 1 unit Reset switch Turns the power on off Indoor fan speed button LOW FAN SPEED indicator MIDDLE FAN SPEED indicator HIGH FAN SPEED indicator AUTO FAN SPEED indicator Operation mode selection button Se lects the operation mode AUTO mode indicator COOLING indicator DEHUMIDIFYING indica tor FAN ONLY OPERATIO...

Страница 9: ... remote control towards the signal receiver at the bottom of the air conditioner to operate it Operating method NOTE If the display screen of the remote control starts to fade replace the batteries NOTE The remote control may operate other electronic devices if pointed towards them Make sure to point the remote control towards the signal receiver of the air conditioner For proper operation use a s...

Страница 10: ... range is 16 C 60 8 F 31 C 88 F Removing humidity Dehumidifying operation This mode removes excess moisture from an environment with high humidity or in the rainy season in order to prevent mold from setting in This mode adjusts the room temperature and the fan speed automatically to maintain the optimal level of humidity 1 Press to turn on the power 2 Press repeatedly to select the dehu midifying...

Страница 11: ...sts automatically Adjusting the air flow direction To adjust the direction of the air flow horizon tally press repeatedly and select the de sired direction Select to adjust the direction of the air flow automatically NOTE Adjusting the air flow direction vertically may not be supported depending on the model Adjusting the air deflector arbitrarily may cause product failure If you restart the air c...

Страница 12: ...ir conditioner automatically at a set time To activate the time on the air conditioner should be off 1 Press The below flickers at the bottom of the display screen 2 Press to select the mode 3 Press or to select the temparature in Cool Heat Mode 4 Press to select the wind speed in Auto Cool Fan Heat Mode 5 Press C NOTE In cooling or auto mode the set tempera ture will automatically raise by1 every...

Страница 13: ...ble the function press the reset switch and hold it for 10 seconds The unit will beep 3 times and the lamp will blink 1 times The feature can be changed according to type of model The feature can be changed according to type of model Operating the air conditioner without the remote control You can use the reset switch of the indoor unit to operate the air conditioner when the remote control is una...

Страница 14: ...t with technician Air filter CAUTION Turn off the power and unplug the power cord before you perform any maintenance other wise it may cause electric shock Never use water that is hotter than 40 C when you clean the filters It may cause deforma tion or discoloration Never use volatile substances when you clean the filters They may damage the surface of the product NOTE The location and shape of th...

Страница 15: ... with a vacuum cleaner or with warm water If dirt is difficult to remove wash the filter in lukewarm water with detergent 5 Dry the filter in the shade Cleaning the carbon filter 1 Turn off the power and unplug the power cord 2 Open the front cover Lift up both sides of the cover slightly The feature can be changed according to type of model 3 Remove the carbon filter from Air filter 4 Clean the c...

Страница 16: ...lug the power cord and contact the service center Water leaks from the indoor unit even when the humidity level is low The power cord is damaged or generating excessive heat A switch a circuit breaker safety ground or a fuse is not operated properly The air conditioner does not work The air conditioner is unplugged Check whether the power cord is plugged into the outlet A fuse is blown or the powe...

Страница 17: ...cted In the air circulation operation air blows from the air conditioner without cooling or heating the indoor air Switch the opera tion mode to the cooling operation It is not possible to adjust the fan speed The auto operation jet operation or dehu midifying operation is selected In some operation modes such as the jet or dehumidifying operation modes you cannot adjust the fan speed Select an op...

Страница 18: ...18 ENGLISH ERPR information Dofin Ltd Boiarkino Ozersky area Moscow region 140573 Russia Production date and origin can be found on the box label ...

Страница 19: ......

Отзывы: