5-19
(TROUBLE 7) Heater Relay 5- Up. sheath Heater
Relay 6- Lo. sheath Heater
Relay 7- H Ceramic Heater
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Heater is not
operating.
Abnormal.
Normal.
Normal.
Heater.
Thermostat and
relay 5, 6, 7.
Abnormal.
Malfunction of the
thermostat and
relay 5, 6, 7
Malfunction of the
heater.
Replace.
Wire connection.
No continuity.
Open or loosen.
Replace or
connect tightly.
Replace.
2. Lower tempera-
ture the oven.
Abnormal.
Normal.
Heater.
Thermostat and
relay 5, 6, 7.
Abnormal.
Malfunction of the
thermostat and
relay 5, 6, 7
Malfunction of the
heater.
Replace.
Replace.
(TROUBLE 6) Oven does not cook properly when programmed for the set power level
(Operates properly on HIGH)
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Output is full when
you set lower
power level.
Abnormal.
Disconnect the
wire leads from
relay 4 and check
continuity relay 4.
(Operate the unit)
Defective P.C.B.
assembly.
Replace P.C.B.
assembly.
NOTE:
* Make sure the wore leads are in the correct position.
* When removing the wire leads from parts, Be sure to grasp the connector not the wires.
* When removing the magnetron, be sure to install the magnetron gasket in the correct position and in
good condition.