ONE POINT REPAIR GUIDE
NO SOUND
2-4. PORTABLE
2-4-1. Solution
Replace MAIN board.
2-4-2. How to troubleshoot (Countermeasure)
1) Please check the soldering status of portable jack and check IC200 pin3 (VCC_5V), pin4 (D_3.3V).
2) If portable jack and voltage has abnormal status, replace MAIN board.
2-4-3. Service hint (Any picture / Remark)
< MAIN board bottom view >
IC200
IC200
Содержание SK6Y