3260 / 4100 Dual-Handed Swingbolt Lock Instructions
MANAGER PROGRAMMING
CHANGING YOUR CODE
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
If your unit is programmed for Dual Code, each code must
be changed independently. Follow these instructions for
each code change.
1
Enter “zero” six times.
2
Enter your existing six (6) digit code one time.
3
Enter your NEW six (6) digit code two times.
4
If a mistake is made wait thirty (30) seconds and repeat
steps
1
-
3
.
5
Test lock operation several times before closing the door.
• Valid Code Entry
- Double signal after valid six (6) digit
code is entered.
• Invalid Code Entry
- Triple signal and old code is still valid.
OPENING THE LOCK
1
Enter valid six (6) digit code.
2
The lock will indicate a valid code entry with a double
signal.
3
Within four (4) seconds, turn handle to the open position.
4
Pull door open.
• Invalid Code Entry
- Lock will signal three (3) times.
• Security Considerations
- On safes using more than one
lock the swingbolt lock must lock first.
Suggested Keypads
3715 LGBASIC
II
Input
3000 Round Entry
ADD USER
(If Manager, Time Delay Override, Remote Override,
or Dual Combination feature activated.)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1
Enter Manager code and HOLD DOWN LAST DIGIT of
CODE until the lock signals with two sets of double beeps.
2
PRESS 1. Lock signals twice. Lock will only signal twice
if the user code is not already in use. It will beep once if a
user is already installed and three (3) times if the function
has not been programmed in the lock.
3
Enter user code twice. The lock signals twice after each
valid entry.
4
If a mistake is made wait thirty (30) seconds and repeat
steps
1
-
3
.
• Valid Code Entry
- Double signal after valid six (6) digit
code is entered.
• Invalid Code Entry
- Triple signal and old code is still valid.
DISABLE USER
(Manager feature only.)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1
Enter Manager code and HOLD DOWN LAST DIGIT of
CODE until the lock signals with two sets of double beeps.
2
PRESS 2. Lock signals once.
3
User is temporarily disabled.
4
If a mistake is made wait thirty (30) seconds and repeat
steps
1
-
3
.
• Valid Code Entry
- Double signal after valid six (6) digit
code is entered.
• Invalid Code Entry
- Triple signal and old code is still valid.
MANAGER CODE
(Factory set to 1-2-3-4-5-6)
...............
• Add/Remove Second User
• Enable/Disable Second User
USER CODE .....................................................................
• Open Lock
• Change Code
TIME DELAY OVERRIDE .................................................
• Ability to add second combination to override delay period
DUAL CODE .....................................................................
• Two combinations required to open
TIME DELAY .....................................................................
• Delay period 1 - 99 minutes
• Open period 1 - 19 minutes
SILENT SIGNAL ALARM
(Optional Alarm Box Required)
.....
• Duress signal if last number of code(s) is entered using one number
higher or one number lower.
DISABLE LOCK
(Optional Alarm Box Required)
.....................
• Input signal disables opening of lock by valid code
3900 LGACCESS
Handle
STANDARD FEATURES
WRONG TRY PENALTY
• Four (4) consecutive invalid codes initiates five minute delay period.
LOW BATTERY WARNING
• Repeated audio and visual signal (LED flashing and repeated beeping) during
opening indicates battery low.
AUDIO AND VISUAL SIGNAL
• Double signal (LED flashes and unit beeps) indicates entry is valid or accepted.
• Triple signal indicates invalid or not accepted.
PROGRAMMABLE FEATURES
ACTIVE
© copyright 2006
12-223v3
LA GARD INC - A Member of The Kaba Group
4100 is a new part