SAFETY PRECAUTIONS
Many electrical and mechanical parts in this chassis have special safety-related characteristics. These parts are identified by in
the Schematic Diagram and Replacement Parts List.
It is essential that these special safety parts should be replaced with the same components as recommended in this manual to
prevent X-RADIATION, Shock, Fire, or other Hazards.
Do not modify the original design without permission of manufacturer.
General Guidance
An lsolation Transformer should always be used during
the servicing of a receiver whose chassis is not isolated from
the AC power line. Use a transformer of adequate power rating
as this protects the technician from accidents resulting in
personal injury from electrical shocks.
It will also protect the receiver and it’s components from being
damaged by accidental shorts of the circuitry that may be
inadvertently introduced during the service operation.
If any fuse (or Fusible Resistor) in this TV receiver is blown,
replace it with the specified.
When replacing a high wattage resistor (Oxide Metal Film
Resistor, over 1W), keep the resistor 10mm away from PCB.
Keep wires away from high voltage or high temperature parts.
Due to high vacuum and large surface area of picture tube,
extreme care should be used in handling the Picture Tube.
Do not lift the Picture tube by it’s Neck.
Before returning the receiver to the customer,
always perform an AC leakage current check on the exposed
metallic parts of the cabinet, such as antennas, terminals, etc.,
to be sure the set is safe to operate without damage of
electrical shock.
Leakage Current Cold Check(Antenna Cold Check)
With the instrument AC plug removed from AC source,
connect an electrical jumper across the two AC plug prongs.
Place the AC switch in the on position, connect one lead of
ohm-meter to the AC plug prongs tied together and touch other
ohm-meter lead in turn to each exposed metallic parts such as
antenna terminals, phone jacks, etc.
If the exposed metallic part has a return path to the chassis, the
measured resistance should be between 1M‰ and 5.2M‰.
When the exposed metal has no return path to the chassis the
reading must be infinite.
An other abnormality exists that must be corrected before the
receiver is returned to the customer.
Leakage Current Hot Check
(See below Figure)
Plug the AC cord directly into the AC outlet.
Do not use a line Isolation Transformer during this check.
Connect 1.5K/10watt resistor in parallel with a 0.15uF capacitor
between a known good earth ground (Water Pipe, Conduit, etc.)
and the exposed metallic parts.
Measure the AC voltage across the resistor using AC
voltmeter with 1000 ohm/volt or more sensitivity.
Reverse plug the AC cord into the AC outlet and repeat AC
voltage measurements for each exposed metallic part. Any
voltage measured must not exceed 0.75 volt RMS which is
corresponds to 0.5mA.
In case any measurement is out of the limits specified, there is
possibility of shock hazard and the set must be checked and
repaired before it is returned to the customer.
Leakage Current Hot Check circuit
1.5 Kohm/10W
To Instrument's
exposed
METALLIC PARTS
Good Earth Ground
such as WATER PIPE,
CONDUIT etc.
AC Volt-meter
I M P O RTA N T S A F E T Y N OTICE
0.15uF
Содержание RT-52
Страница 24: ... 24 5 General Control Signal ...
Страница 25: ... 25 PRINTED CIRCUIT BOARD MAIN TOP ...
Страница 26: ... 26 MAIN BOTTOM ...
Страница 27: ... 27 COMPONENT TOP COMPONENT BOTTOM SIDE A V PRE AMP LED AC INPUT ...
Страница 28: ... 28 LCD DRIVER TOP CONTROL ...
Страница 29: ... 29 LCD DRIVER BOTTOM ...
Страница 30: ... 30 DIGITAL TOP DIGITAL BOTTOM ...
Страница 31: ... 31 TUNER TOP TUNER BOTTOM ...
Страница 32: ... 32 SMPS POWER S W INTERFACE BALLAST ...
Страница 33: ...MEMO 33 ...
Страница 48: ...P No 3854VA0117C S1 1 2 2003 10 8 ...
Страница 49: ...P No 3854VA0117C S1 2 2 2003 10 8 ...
Страница 50: ...P No 3854VA0117C S2 1 2 2003 10 8 ...
Страница 51: ...P No 3854VA0117C S2 2 2 2003 10 8 ...
Страница 52: ...S VC SHEET 3854V A0117C S1 S VC SHEET 3854V A0117C S2 S VC SHEET ...