- 10 -
1. Application Object
This instruction is for the application to the LCD TV.
2. Adjustment
2.1 Adjustment Details
The machine can be adjusted by it self automatically
but even for self-adjustment it needs someone to
operate it.
2.2 Auto Gain/Offset adjustment
2.2.1 RF Mode adjustment
(RZ-20LA90, RT-20LA90)
2.2.1.1 Adjustment preparation
■
Execution of RF no signal during Heat Run over
30min...
2.2.1.2 Auto Gain/Offset adjustment
■
Press IN-START Key by using the Remote Controller
(SVC), after converting to Adjustment-Mode, Press
VOL+Key consecutively in Scaler Auto gain menu.
■
After adjustment is complete, pressing ener key,
stores and completes the process
2.2.1 Component Mode adjustment
(Only RT-20LA90)
2.2.1.1 Adjustment preparation
■
Execution of RF no signal during Heat Run over
30min...
■
The component jack(Y, Pb, Pr) of LCD TV is
connected to Y, Pb, Pr Output Signal of Pattern
Generator (MSPG-925 SERISE)
2.2.1.2 Auto Gain/Offset adjustment
■
Convert to Component Mode in Input-Mode.
■
Select MODEL : 228 (480p MODE, Y:100%,
Pb/Pr:75%) in Pattern Generator
Select PATTERN : 33 (Color Bar Pattern signal) in
Pattern Generator (MSPG-925 SERISE)
■
Press IN-START Key by using the Remote
Controller(SVC), after converting to Adjustment-Mode,
press VOL+Key consecutively in Auto Gain Menu.
■
After adjustment is complete, pressing enter key,
stores and completes the process