PROGRAMMING MODE
1.
Pressing the Start button cycles to the next test function.
Number of times
the Start
button is pressed
Checking point
Display
None
LqC 1
1 time
Check the version and code of ma-
chine.
Gas Coin type : P1:Og
Gas Card type : P1:Cg
Gas OPL type : P1:Pg
Version and code of machine (All LED on)
Display 88:88 and P1:XX and gU:XX and gd:XX alter
-
nately.
XX is product type or the version number.
2 time
PDA CHECK
Ir--
3 time
Motor runs.
Measured moisture value (70~239)
4 time
GAS TYPE: Motor runs.
Current temperature (5~70)
(Displays the temperature inside the drum in ° Celsius.)
5 time
GAS TYPE: GAS valve runs.
Motor+Valve
Current temperature (5~70)
(Displays the temperature inside the drum in ° Celsius.)
6 time
LED & KEY CHECK
Press High Temp. button.
Press Med Temp. button.
Press Low Temp. button.
Press No Heat button.
Version and code of machine
7 time
Test ends.
LqC1
During check, if the
door is open.
Door switch
(Motor & Heater Off, Buzzer beeps
seven times)
dE
(The door is open. Please close the door completely)
During check, if the
door is closed
Test goes back at step 3.
(Motor on & Heater Off)
Measured moisture value (70~239)
NOTE