background image

OWNER’S MANUAL

COMMERCIAL DRYER

Before beginning installation, read these instructions carefully. this will 

simplify installation and ensure that the dryer is installed correctly and 

safely. leave these instructions near the dryer after installation for future 

reference.

P/NO. : MFL62512875

www.lg.com

MODEL

RN1329AD1S / RV1329AD1S
RN1329AD5S / RV1329AD5S
RN1329AD6S / RV1329AD6S

RN1329AN4S / RV1329AN4S
RN1329AN7S / RV1329AN7S
RN1329AN1S / RV1329AN1S

RN1329A4S  /  RV1329A4S
RN1329A7S  /  RV1329A7S
RN1329A1S  /  RV1329A1S

MFL62512875_140916.indd   1

2014.9.16   10:23:44 AM

Содержание RN1329A1S

Страница 1: ...rectly and safely leave these instructions near the dryer after installation for future reference P NO MFL62512875 www lg com MODEL RN1329AD1S RV1329AD1S RN1329AD5S RV1329AD5S RN1329AD6S RV1329AD6S RN1329AN4S RV1329AN4S RN1329AN7S RV1329AN7S RN1329AN1S RV1329AN1S RN1329A4S RV1329A4S RN1329A7S RV1329A7S RN1329A1S RV1329A1S MFL62512875_140916 indd 1 2014 9 16 10 23 44 AM ...

Страница 2: ...RTISTIC DESIGN Modern front panel look and big clear glass door make your dryer look stylish EASY OF USE An entire selection of user friendly functions makes operating the dryer easy ULTRA CAPACITY The larger drum enables better tumbling and less tangling and wrinkling of the laundry PRODUCT FEATURES MFL62512875_140916 indd 2 2014 9 16 10 23 44 AM ...

Страница 3: ...tial hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER WARNING or CAUTION These words mean wDANGER You will be killed or seriously injured if you don t immediately follow instructions wWarning You can be killed or seriously injured if you don t follow instructions wcaution You may be slightly injured or cause damage to t...

Страница 4: ...tine waxes and wax removers should be washed in hot water with an extra amount of detergent before being dried in the tumble dryer Items such as foam rubber latex foam shower caps waterproof textiles rubber backed articles and clothes or pillows fitted with foam rubber pads should not be dried in the tumble dryer Fabric softeners or similar products should be used as specified by the fabric soften...

Страница 5: ... of the products or the replacement of a defective part shall be borne by the owner READ ALL INSTRUCTIONS BEFORE USE wWarning For your safety the information in this manual must be followed to minimize the risk of fire or explosion electric shock or to prevent property damage Injury to persons or death WHAT TO DO IF YOU SMELL GAS Applicable for Gas models Do not store or use gasoline or other flam...

Страница 6: ...hen using this appliance follow basic precautions including the following Properly ground dryer to conform with all governing codes and ordinances Follow details in the installation instructions Electric shock can result if the dryer is not properly grounded Before use the dryer must be properly installed as described in this manual Electric shock can result if the dryer is not properly grounded I...

Страница 7: ... diameter ductwork inside the dryer cabinet or for exhausting to the outside Use of plastic or other combustible ductwork can cause a fire Punctured ductwork can cause a fire if it collapses or becomes otherwise restricted in use or during installation Ductwork is not provided with the dryer and you should obtain the necessary ductwork locally The end cap should have hinged dampers to prevent back...

Страница 8: ...s can create an electric shock hazard and or a fire hazard The dryer should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires Never unplug your dryer by pulling on the power cord Always grip p...

Страница 9: ...ation check that the local distribution conditions nature of gas and pressure and the adjustment of the appliance are compatible the method of connection and the installation regulations in the country where the appliance is to be installed if such regulations exist also the ventilation dimensions shall be given for the purposes of installation in those countries where there are no appropriate reg...

Страница 10: ...cycle time 30 8 Special priced dryer cycle time 31 9 Value of coin 1 32 10 Value of coin 2 Set up for top off price and e suds coin pulse 33 11 Penny increment pricing offset 34 12 Top off time 35 13 Beep volume 36 14 Time to keep the coin Use only for coin type 37 15 Product type setup coin card type or OPL setup 38 Programming Mode Test Mode 39 1 Lqc1 40 2 Factory reset EEPt 41 3 Time Set Up 42 ...

Страница 11: ...etailed information Single dryer size 686mm W x 764mm D x 983mm H Stack dryer size 686mm W x 764mm D x 1954mm H Electric Dryer Max capacity 10kg Gas Dryer Max capacity 10 2kg Weight 59 4 kg Specifications are subject to change by manufacturer Specifications subject to change by manufacturer NOTE MFL62512875_140916 indd 11 2014 9 16 10 23 47 AM ...

Страница 12: ...RN1329AD5S RV1329AD5S Stack lower RN1329AD6S RV1329AD6S 1 2 4 3 4 1 2 4 3 1 2 4 3 1 2 4 OPL type Side by side RN1329A4S RV1329A4S Stack upper RN1329A7S RV1329A7S Stack lower RN1329A1S RV1329A1S 1 2 4 3 1 Display LED 2 Cycle button 3 Start button 4 Status LED MFL62512875_140916 indd 12 2014 9 16 10 23 50 AM ...

Страница 13: ...329AN7S 1 2 4 3 1 2 4 3 1 2 4 3 1 2 4 3 Stack lower RN1329AN1S RV1329AN1S 1 2 4 3 1 2 4 3 1 2 4 3 1 2 4 3 1 Display LED 2 Cycle button 3 Start button 4 Status LED Control panel features Coin type Side by side RN1329AN4S RV1329AN4S MFL62512875_140916 indd 13 2014 9 16 10 23 54 AM ...

Страница 14: ...ng sturdy fabrics such as work casual clothes Medium heat Low Temp Use for drying synthetic fabrics washable knit fabrics and noiron finishes Low heat No Heat Use for items that require heat free drying such as plastics or rubber Start button The Start LED flashes when the full vend price has been satisfied then the cycle has been chosen or the machine is paused The Start LED flashes when a card i...

Страница 15: ...e card should have enough balance to satisfy increasing time The operating time can be increased to 10 minutes 10p default by adding more coins When the COOL DOWN has been working if time is added it goes back to the DRYING Time can be added up 99 minutes 5 Change cycle You cannot change the cycle while the machine is running But if the door is opened the machine stops temporarily and the cycle ca...

Страница 16: ... same time 2 Push the Med Temp button 3 times 3 Push the Start button 4 Display will show How to use button You can change Dryer vend price cycle time and Cycle parameters etc Press button Description High Temp Move to upper level Med Temp Move to the mode in the same level Low Temp Move to the modes in the same level No Heat Start Enter the selected mode If you turn on the power without connectin...

Страница 17: ...mp button to move the upper level 3 Press Med Temp or Low Temp button if you want to be at the same level 4 Press Start button to enter the details of Set up Diagnostic Tests mode is to set price value time value and vend type etc consists of line test reset free cycle and kill cycle Is to collect the usage data Structure of Programming mode Do not use It is only used in inspecting the machine NOT...

Страница 18: ...nd Low Temp button at the same time 2 Push the Med Temp button 3 times 3 Push the Start button 4 Display will show is to set price value time value and vend type etc consists of line test reset free cycle and kill cycle Is to collect the usage data Structure of Programming mode Do not use It is only used in inspecting the machine NOTE MFL62512875_140916 indd 18 2014 9 16 10 24 3 AM ...

Страница 19: ...g set up mode You will see LqC1 Button Display Press the High Temp button Press the Med Temp or the Low Temp button until appears in the display Press the Start button Press the Start button Display previous regular price Press Med Temp or Low Temp button to set regular price The vend price can be set from 0 to 9 90 in 10p increments Press the Start button The machine sets up the regular price the...

Страница 20: ...e Start button Press the Med Temp or the Low Temp button until appears in the display Press the Start button Display previous special price Press Med Temp or Low Temp button to set special price The vend price can be set from 0 to 9 90 in 10 p increments Press the Start button The machine sets up the regular price then advances to the next process automatically 1 Continue to set up the next price ...

Страница 21: ...w Temp button until appears in the display Press the Start button Press the Med Temp or the Low Temp button until appears in the display Special price days apply or not Disabled Add super wash apply or not Select vend type This function is not available Pre wash apply or not Top off apply or not only for dryer Disable Enable MFL62512875_140916 indd 21 2014 9 16 10 24 9 AM ...

Страница 22: ...appears in the display Press the Start button Display Press the Start button Press Med Temp or Low Temp button and then select or Coin type Card type One or the other will display Press the Start button The machine sets up the special price then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on...

Страница 23: ... button until appears in the display Press the Start button Press the Med Temp or the Low Temp button until appears in the display Press the Start button Display Press the Med Temp or the Low Temp button until appears in the display Press the Start button Press Med Temp or Low Temp button and then select or Disable Enable One or the other will display Press the Start button The machine sets up the...

Страница 24: ...tton until appears in the display Press the Start button Press Med Temp or Low Temp button and then select or Disable Enable One or the other will display Press the Start button The machine sets up the Vend type then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type ...

Страница 25: ...igh Temp button Press the Med Temp or the Low Temp button until appears in the display Press the Start button Press the Med Temp or the Low Temp button until appears in the display Press the Start button Display Structure of Sunday Monday Tuesday Wednesday Thursday Friday Saturday MFL62512875_140916 indd 25 2014 9 16 10 24 14 AM ...

Страница 26: ...ress the Start button Display Press the Start button Press Med Temp or Low Temp button and then select or Disable Enable One or the other will display Press the Start button The machine sets up the special price day Sunday then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch...

Страница 27: ... previous special price beginning time Press Med Temp or Low Temp button to select time between 0 and 23 Press the Start button The machine sets up the special price beginning time then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack typ...

Страница 28: ...mp or Low Temp button to select time between 1 and 24 Press the Start button The machine sets up the special price ending time then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack type 1 Control panel open 2 Turn on off toggle switch OPL...

Страница 29: ...ious regular priced dryer cycle time Press Med Temp or Low Temp button to select time between 10 and 99 Press the Start button The machine sets up the regular priced dryer cycle time then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack t...

Страница 30: ...d 99 Press the Start button The machine sets up the special priced dryer cycle time then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack type 1 Control panel open 2 Turn on off toggle switch OPL Coin Type Press High Temp twice CCCC washi...

Страница 31: ...ue Press Med Temp or Low Temp button to select value of coin 1 The value can be set fronm 0 to 9 90 in 10 p increments Press the Start button The machine sets up the value of coin 1 then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack ty...

Страница 32: ... 9 90 in 10 p increments Press the Start button The machine sets up the value of coin 2 then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack type 1 Control panel open 2 Turn on off toggle switch OPL Coin Type Press High Temp twice Coin t...

Страница 33: ... penny increment pricing offset Press Med Temp or Low Temp button to select value of PIPo 0 4 Press the Start button The machine sets up the PIPo then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack type 1 Control panel open 2 Turn on of...

Страница 34: ...splay previous top off time Press Med Temp or Low Temp button to select time between 1 and 30 Press the Start button The machine sets up the top off time then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack type 1 Control panel open 2 Tu...

Страница 35: ...on Display previous value Press Med Temp or Low Temp button to select High or Low or Off Press the Start button The machine sets up the beep volume then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack type 1 Control panel open 2 Turn on ...

Страница 36: ...t button Display previous value Press Med Temp or Low Temp button to select time between 1 180 or Disable Press the Start button The machine sets up the time to keep the coin then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack type 1 Co...

Страница 37: ...us value Press Med Temp or Low Temp button and then select or Coin Card type setting OPL type setting One or the other will display Press the Start button The machine sets up the time to keep the coin then advances to the next process automatically 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the se...

Страница 38: ...service card card type Turn on off toggle switch Coin type 2 High Temp Press the High Temp button Then appears in the display 3 Start Enter the diagnostic test mode OPL Coin Type 1 Entering programming mode Push and hold the High Temp and Low Temp at the same time After that push Med Temp button for 3 times Push Start button 2 High Temp Press the High Temp button Then appears in the display 3 Star...

Страница 39: ...he drum in Celsius 5 time ELECTRIC TYPE Heater runs Motor Heater 1 Heater 2 5400W GAS TYPE GAS valve runs Motor Valve Current temperature 5 70 Displays the temperature inside the drum in Celsius 6 time LED KEY CHECK Press High Temp button Press Med Temp button Press Low Temp button Press No Heat button Version and code of machine 7 time Test ends LqC1 During check if the door is open Door switch M...

Страница 40: ...factory reset is done is displayed 1 Continue to set up the next mode 2 Stop the change of setup value and go back to ready mode Coin type Turn on off toggle switch Card type Pull the service card Stack type 1 Control panel open 2 Turn on off toggle switch OPL Coin Type Push High Temp Low Temp and the 3 Dryer default value for CARD COIN machine Drying time 50 Minute Top off time 10 Minute Drying t...

Страница 41: ...s automatically Press Med Temp or Low Temp button to select day between 01 and 31 Press the Start button The machine sets up the day then advances to the next process automatically Press Med Temp or Low Temp button to select hour between 00 and 23 Press the Start button The machine sets up the hour then advances to the next process automatically Press Med Temp or Low Temp button to select minute b...

Страница 42: ... the Start button Press the Med Temp button until appears in the display Press the Start button Display will show Select the course you desire In case of dryer card type it has to insert the cash card after removing the service card Then press the cycle course and the start button It is only applicable to the dryer s card type specially and there is no subtraction in card balance at the Courtesy c...

Страница 43: ...Press the Start button Press the Med Temp button until appears in the display Press the Start button Display with beeping Go back to ready mode Insert cycle kill card Descriptions Display Display the current time and Display with beeping Go back to ready mode OPL type Dryer machine will end the cycle by opening the door NOTE MFL62512875_140916 indd 43 2014 9 16 10 24 29 AM ...

Страница 44: ...r 5 dELC Dryer Moisture Sense dELC is not available in dryer It can t enter 6 ItrC Interval Regular Cycles Number of Regular cycles 0 65535 7 ItCC Interval Regular Cold Cycles ItCC is not available in dryer It can t enter 8 ItAC Interval Regular Warm Cycles ItAC is not available in dryer It can t enter 9 ItHC Interval Regular Hot Cycles ItHC is not available in dryer It can t enter 10 ItSC Interva...

Страница 45: ...come Amount of money for Total Income 0 00 65535 32 IttC Interval Total Cycles Number of Total cycles 0 65535 33 ACtC Accumulated Total Cycles Number of Total cycles 0 65535 34 SCPr Super Cycle Price Scpr is not available in dryer It can t enter 35 toPr Top Off Price 0 00 9 90 36 Itd Interval Money Amount of money for regular cycle 0 65535 37 ACd Accumulated Money Amount of money for regular cycle...

Страница 46: ...ctions and blockages Maintaining Ductwork Vent ductwork should be checked for lint buildup and cleaned at least once per year If any noticeable reduction in airflow or drying performance occurs immediately check ductwork for obstructions and blockages Contact a qualified technician or service provider Cleaning the Lint Filter Always clean the lint filter after every cycle To clean open the dryer d...

Страница 47: ... the upper dryer Sliding kit includes the slide bracket 2 sliding pad 4 screw 10 machine screw 8 1 Sliding bracket 3 Stacking kit Stacking kit is provided in the upper dryer Stacking kit includes the stacking bracket 1 security bracket 3 bolt 1 screw 6 2 Sliding pad 3 Screw 4 Machine screw The machine can be stacked only on the model designated as suitable by LGE Do not stack the washer on the top...

Страница 48: ...r washer in the same position Push the upper dryer matching the slide stacking bracket to make upper and lower front parallel Install the stacking bracket at the rear of the stacked dryer and washer Assemble the six 6 screw to fix the lower washer and upper dryer Please refer to Service Manual for detail to explain the how to stack and fix the machine NOTE MFL62512875_140916 indd 48 2014 9 16 10 2...

Страница 49: ...error code POWER FAIL RECOVERY In case of power failure the machine stops running but the time display remains on showing the time just before power failure Press the Start button after the power is restored then the machine will restart DEFAULT DRYER SETTINGS Default Settings Default Cycle Time Minutes 50 Minutes Cool Down Time Cycle 2 Minutes High Temperature 154 4 F 68 C Medium Temperature 140 ...

Страница 50: ...50 Declaration of Conformity MFL62512875_140916 indd 50 2014 9 16 10 24 48 AM ...

Страница 51: ...51 MFL62512875_140916 indd 51 2014 9 16 10 24 51 AM ...

Страница 52: ...MFL62512875_140916 indd 52 2014 9 16 10 24 53 AM ...

Отзывы: