![LG RE-21CB50VX Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/lg/re-21cb50vx/re-21cb50vx_service-manual_1903492010.webp)
- 10 -
ANT IN
75
Ω
Fig. 2-1
Fig. 2-2
CPT
board
Remove
Screws
Main
PCB
DISASSEMBLY INSTRUCTIONS
Important note
This set is disconnected from the power supply through the
converter transformer. An isolating transformer is necessary
for service operations on the primary side of the converter
transformer.
Back Cabinet Removal
Remove the screws residing on the back cabinet and carefully
separate the back cabinet from the front cabinet. (Fig. 2-1).
Chassis Assy Removal
Grasp both side of Frame and pull it backward smoothly.
CPT Removal
1. Pull out the CPT board from the CPT neck.
2. Place the front cabinet on soft material not to mar the front
surface or damage control knobs.
3. Remove 5 screws securing the picture tube mounting
brackets to the front cabinet.
4. Carefully separate CPT from the front cabinet.
PICTURE TUBE HANDLING CAUTION
Due to high vacuum and large surface area of picture tube, great
care must be exercised when handling picture tube. Always lift
picture tube by grasping it firmly around faceplate.
NEVER LIFT TUBE BY ITS NECK! The picture tube must not be
scratched or subjected to excessive pressure as fracture of
glass may result in an implosion of considerable violence which
can cause personal injury or property damage.
Содержание RE-21CB50VX
Страница 18: ... 18 EXPLODED VIEW 21Q21 22 913 170 150 153 112 400 943 530 120 124 123 300 700 330 315 320 310 174 OPTION 520 ...
Страница 20: ... 20 EXPLODED VIEW 21Q61 62 120 300 124 123 600 700 330 320 310 400 943 913 170 150 153 112 530 174 OPTION 520 ...
Страница 29: ...P NO 3854VA0083A S 2001 04 20 ...
Страница 30: ...PRINTED CIRCUIT BOARD ...
Страница 32: ...SVC SHEET 3854V A0083A S SVC SHE ...