Test Run
Installation Manual
15
ENGLISH
Checking the refrigerant leak detector setting - Wireless Remote Control
1. Press the RESET button once while pressing the Wind
Intensity button and then the display window appears as
shown in the left figure.
2. Set the address with the temperature control button.
- Press the temperature up button one at a time
to reach the desired temperature.
(Select the function number.)
- Press the temperature down button one at a
time. (Designate the setting value.)
3. Designate the function number and the setting value
and then press the Start/Stop button to complete the
setting.
E.g., If you press the temperature increase button two (2)
times and then press the temperature decrease button
two (2) times, the message shown on the right will appear
4. When the setting ends, press the RESET button to exit
the installer setting mode.
Function Number
Setting Value
Remote Control
Display Window
ȯ
The installer setting mode is a mode for setting the detailed features of the indoor unit.
If the installer setting mode is set incorrectly, a product defect, user injury, or property damage
may occur. It must be set only by qualified installation technicians who hold an installation
license. Any and all problems arising from the installation or arbitrary changes without having
such a license are the responsibility of the installer. In this instance, we do not conduct services
free of charge.