7. Remove the screw that attaches the electric heater wire to
the side of the indoor fan housing.
8. Remove the 3 screws which fasten the top cover assembly.
9. Position water spraying plastic tube into the electric heater
cover. Make sure that the three pairs(total of six) of plastic
tongues snap into the corresponding metal slots of the
heater frame as shown in fig. 27. Then install one of the
three rubber elbows(ref. fig. 31) at the inlet of the spraying
tube and through the rubber grommet.
10. Place the top cover assembly back into the unit.
11. Install tube #1 and tube #2 (ref. fig. 31) on the pump
assembly using the rubber elbows as shown in fig. 28.
12. Position pump assembly to the basepan as shown in fig.
29 and fasten the pump bracket to the basepan using the
three screws provided.
13. Insert tube #2 of the pump assembly through the plastic
grommet of the sheet metal partition as shown in fig. 30.
Then connect the end of tube #2 to the plastic elbow
coming out of the inlet of the spraying tube.
Figure 26
Figure 29
Figure 30
Figure 27
Figure 28