background image

- To re-enable the function, press the On/

Off button and hold it for 6 seconds. The
unit will beep twice and the blue lamp
will blink 4 times.

ON/OFF

button

Disabling auto restart

NOTE

!

If you press and hold the On/Off button
for 3 – 5 seconds instead of 6 seconds,
the unit will switch to the test operation.
In the test operation, the unit blows out
strong air for cooling for 18 minutes and
then returns to the factory default set-
tings.

ADVANCED FUNCTIONS

16

ENGLISH

* The feature can be changed according a

type of model.

* The feature can be changed according a

type of model.

- For cooling only models, the temperature

is set to 22°C (72°F).

Room temp.

Set temp.

Operation

mode

Below 21°C

24°C

Heating 
operation

Above 21°C
and below
24°C

23°C

Dehumidify-
ing operation

Above 24°C

22°C

Cooling 
operation

Ionizer Purification operation

Ion particles from Ionizer developed by LG
sterilize the aerial bacteria and other harmful
substances.

1

Press 

|

to turn on the power.

2

Press 

A

.

K

is displayed on the display screen.

NOTE

!

• You can use this function by pressing 

without turning the air conditioner

on.

• This function may not be supported, de-

pending on the model.

• Do not touch Ionizer during operation.

Restarting the air conditioner
automatically

When the air conditioner is turned on again
after a power failure, this function restores
the previous settings. This function is a fac-
tory default setting.

1

Open the front cover.

- Lift up both sides of the cover slightly.

2

Press the On/Off button and hold it for 6
seconds.

- The unit will beep twice and the lamp will

blink 6 times.

Содержание P09RL

Страница 1: ...OWNER S MANUAL Please read this manual carefully before operating your set and retain it for future reference AIR CONDITIONER TYPE WALL MOUNTED P NO MFL67415223 www lg com ...

Страница 2: ...irection of the air flow vertically or horizontally to circulate indoor air Speed up the fan to cool or warm indoor air quickly in a short period of time Open windows regularly for ventilation as the indoor air quality may deteriorate if the air con ditioner is used for many hours Clean the air filter once every 2 weeks Dust and impurities collected in the air filter may block the air flow or weak...

Страница 3: ...r and fuse conforming with the rating of the air conditioner Fail ure to do so may result in electric shock or product failure Contact an authorized service center when you install or relocate the air conditioner Failure to do so may result in serious injury or product failure Always use a power plug and socket with a ground terminal Failure to do so may result in electric shock or product failure...

Страница 4: ...ere is a noise smell or smoke coming from the air conditioner Failure to do so may result in explosion or fire Stop operating and close the window in strom or hurricane If possible remove the product from the window before hurricane arrives Contact an authorized service center when the air conditioner is submerged into water due to flood ing Failure to do so may result in explosion or fire Be caut...

Страница 5: ...metal parts of the air conditioner when you remove the air filter It may result in se rious injury or product failure Do not place any objects on the air conditioner It may result in product failure Always insert the filter securely after cleaning Clean the filter every two weeks or more often if necessary Do not insert hands or other objects through the air inlet or outlet while the air condition...

Страница 6: ...set time 12 Turning off the air conditioner automatically at a set time 12 Canceling the timer setting 12 Setting sleep mode 13 ADVANCED FUNCTIONS 13 Changing room temperature quickly 13 Indoor air purification 13 Auto Clean operation 14 Auto operation 14 Auto Changeover operation 14 Silent mode 15 Energy Control mode 15 Display screen brightness 15 Operating the air conditioner without the remote...

Страница 7: ... OFF button Air inlet Air filter Front grille Vertical louver Air outlet Ionizer Horizontal vane 3M filter NOTE The number of operation lamps and their locations may vary depending on the model of the air conditioner 7 BEFORE USE ENGLISH Indoor unit The feature can be changed according a type of model The feature can be changed according a type of model ...

Страница 8: ...ration mode selection button Se lects the operation mode Cooling operation A Auto operation or auto changeover C Dehumidify ing operation D Heating operation B Air circulation E M Jet cooling heating button Warms up or cools down the indoor temperature within a short period of time i Air flow direction button Adjusts the air flow direction vertically k S Temperature display button Displays the roo...

Страница 9: ... the holder before at taching it to the wall 3 Fix the holder by fastening the 2 screws firmly with a screwdriver 4 Slide the remote control into the holder Point the remote control towards the signal receiver at the bottom of the air conditioner to operate it The feature can be changed according a type of model NOTE If the display screen of the remote control starts to fade replace the batteries ...

Страница 10: ...range is 16 C 60 F 30 C 86 F Removing humidity Dehumidifying operation This mode removes excess moisture from an environment with high humidity or in the rainy season in order to prevent mold from setting in This mode adjusts the room temperature and the fan speed automatically to maintain the optimal level of humidity 1 Press to turn on the power 2 Press f repeatedly to select the dehu midifying ...

Страница 11: ...direction Select to adjust the direction of the air flow automatically Setting the timer You can use the timer function to save energy and to use the air conditioner more efficiently Setting the current time 1 Press p and hold it for longer than 3 sec onds The AM PM icon flickers at the bottom of the display screen NOTE Adjusting the air flow direction vertically may not be supported depending on ...

Страница 12: ...he timer setting 1 Press m or n to select the timer setting to cancel 2 Press p To cancel all timer settings press p Setting sleep mode Use the sleep mode to turn off the air condi tioner automatically when you go to sleep 1 Press to turn on the power 2 Press l 3 Press E or F to select the hour up to 7 hours 4 Press p to finish T is displayed on the display screen in sleep mode NOTE In the Cooling...

Страница 13: ...30 minutes Indoor air purification Auto Clean operation In the cooling and dehumidifying operations moisture is generated inside the indoor unit Use the auto cleaning function to remove such moisture 1 Press to turn on the power 2 Press H J is displayed on the display screen If you turn off the power the fan oper ates for 30 minutes and cleans the inside of the indoor unit NOTE In Air Circulation ...

Страница 14: ... 0 Maintain room temperature 1 Heat slightly 2 Heat NOTE In this mode you cannot adjust the fan speed but you can set the air deflector to rotate automatically This function may not be supported de pending on the model Silent mode It is to prevent potential claims by neighbors reducing noise from outdoor units The outdoor unit sound pressure in cooling and heating mode is decreased by 3dB com pare...

Страница 15: ...ay screen Operating the air conditioner without the remote control You can use the On Off button of the indoor unit to operate the air conditioner when the remote control is unavailable However the fan speed is set to high 1 Open the front cover Lift up both sides of the cover slightly 2 Press the On Off button For cooling and heating models the oper ation mode changes depending on the room temper...

Страница 16: ...4 C Heating operation Above 21 C and below 24 C 23 C Dehumidify ing operation Above 24 C 22 C Cooling operation Ionizer Purification operation Ion particles from Ionizer developed by LG sterilize the aerial bacteria and other harmful substances 1 Press to turn on the power 2 Press A K is displayed on the display screen NOTE You can use this function by pressing A without turning the air conditione...

Страница 17: ... the filters They may damage the surface of the product Do not washed the 3M filter with water because the filter can be damaged NOTE The location and shape of the filters may differ depending on the model Make sure to clean the heat exchanger coils of the outdoor unit regularly as dirt collected in the coils may decrease the operational efficiency or increase energy costs Type Description Interva...

Страница 18: ... with detergent 5 Dry the filter in the shade Cleaning the 3M filter 1 Turn off the power and unplug the power cord 2 Open the front cover and remove the air filter See Cleaning air filter 3 Remove the 3M filter The feature can be changed according a type of model 4 Use a vacuum cleaner to remove dirt Do not wash 3M Filter with water be cause the filter can be damaged NOTE We suggest changing the ...

Страница 19: ...ce center Water leaks from the indoor unit even when the humidity level is low The power cord is damaged or generating excessive heat A switch a circuit breaker safety ground or a fuse is not operated properly The air conditioner does not work The air conditioner is unplugged Check whether the power cord is plugged into the outlet A fuse is blown or the power supply is blocked Replace the fuse or ...

Страница 20: ...ere is a heating source nearby Avoid using a heat generator such as an electric oven or a gas burner while the air conditioner is in operation Air circulation opera tion is selected In the air circulation operation air blows from the air conditioner without cooling or heating the indoor air Switch the opera tion mode to the cooling operation It is not possible to adjust the fan speed The auto oper...

Отзывы: