8
Indoor Unit
Installation
Preparing Work for Installation
The wall you select should be strong and solid enough
to prevent vibration
1) Open panel front
• First, pull the grille bottom, then remove screws
(2 pieces), and close grille bottom again.
• The moment of lifting the both lower parts of panel
front, you can hear sound this panel came out. In
this time panel front is separated.
• After pulling down this panel a bit, separate con-
necting wire from product.
2) Cover pipe and cover side remove
• Remove two screws(for fixing cover pipe)
• Pull up the cover side of desired connecting direc-
tion, then cover side is separated.
• In case connecting direction is left or right, path
through the hole of cover side.
(When path through the hole, take care of burr.)
When connecting pipe path through rear
wall, don’t remove the hole.
3) Drain hose junction
• Remove the rubber stopple of desired drain direc-
tion.
• As the following picture, insert drain hose in the han-
dle of drain pan, and join drain hose and connecting
hose.
NOTICE
Panel Front
Connector
rubber cap
Only one
desiring direction
Connecting
part
Adhesive
Drain
hose
Pipe hole
Side cover