ENGLISH

Airborne Noise Emission

The sound pressure of this product is below the 70dB.

The noise level can vary depending on the site.

The figures quoted are emission level and are not necessarily safe
working levels.

Whilst there is a correlation between the emission and exposure
levels, this cannot be used reliably to determine whether or not further
precautions are required. 

Factor that influence the actual level of exposure of the workforce
include the characteristics of the work room and the other sources of
noise, i.e. the number of equipment and other adjacent processes and
the length of time for which an operator exposed to the noise. Also,
the permissible exposure level can vary from country to country. 

This information, however, will enable the user of the equipment to
make a better evaluation of the hazard and risk.

Limiting concentration

Limiting concentration is the limit of Freon gas concentration where
immediate measures can be taken without hurting human body when
refrigerant leaks in the air. The limiting concentration shall be
described in the unit of kg/m

3

(Freon gas weight per unit air volume)

for facilitating calculation.

Method when insatalling the ducting

- Ducting is to be field supplied

- For prevent water from flowing into the Heat exchanger module,

Make sure the ductiong has slopes down

- You Protect the ducting against reverse airflow from wind.

- If the suction ducting or discharge ducting is connected with the

inside air, it might be impossible to reach the desired room
temperature.

- Connect suction ducting and discharge ducting with the outside air.

TIPS FOR SAVING ENERGY

Here are some tips that will help you minimize the power consumption

when you use the air conditioner. You can use your air conditioner

more efficiently by referring to the instructions below:

+HDWH[FKDQJHU0RGXOH

'XFWLQJ

'XFWLQJ

Total amount of replenishedrefrigerant  

in refrigerant facility (kg)

Capacity of smallest room 

whereindoor unit is installed (m

3

)

Refrigerant concentration(kg/m

3

) =

Limiting concentration: 0.44kg/m

3

(R410A)

Model Designation 

• Product Name : Air conditioner

• Model Name :

Product  information

• Additional information : Serial number is refer to the bar code on the

product.

Model

Name

ARU

N

050

L

M

S

0

No.

1

2

3

4

5

6

7

No.

Signification

1

MULTI V System Outside Unit using R410A

2

Combination of Inverter Type and Cooling Only or Heat Pump

N: Inverter and H/P, V: Inverter and C/O

3

Total Cooling Capacity in Horse Power(HP) unit

EX) 5HP → '050', 8HP → '080'

4

Electrical Ratings

L : 380-415 V 3N~ 50 Hz / 380 V 3N~ 60 Hz
G : 220-240 V~ 50 Hz / 220 V ~ 60Hz

5

Air discharge type

S : Side Discharge
T : Top Discharge
N : Top Discharge Standard H/P(380V)
L : Top Discharge special H/P
M : Module type

6

Model Type

S : Set
C : Compressor Module
E : Heat Exchanger Module

7

Serial number

•  Do not cool excessively indoors. This may be harmful for your health

and may consume more electricity.

•  Block sunlight with blinds or curtains while you are operating the air

conditioner.

•  Keep doors or windows closed tightly while you are operating the air

conditioner.

•  Adjust the direction of the air flow vertically or horizontally to circulate

indoor air.

•  Speed up the fan to cool or warm indoor air quickly, in a short period

of time.

•  Open windows regularly for ventilation as the indoor air quality may

deteriorate if the air conditioner is used for many hours.

•  Clean the air filter once every 2 weeks. Dust and impurities collected

in the air filter may block the air flow or weaken the cooling /

dehumidifying functions.

For your records

Staple your receipt to this page in case you need it to prove the date of

purchase or for warranty purposes. Write the model number and the

serial number here:

Model number :

Serial number :

You can find them on a label on the side of each unit.

Dealer’s name :

Date of purchase :

1,MFL69171214,영어  2018. 2. 23.  오후 4:43  페이지 2

Содержание Multi V ARU Series

Страница 1: ...opean Shared Service Center B V Krijgsman 1 1186 DM Amstelveen The Netherlands Manufacturer LG Electronics Inc Changwon 2nd factory 84 Wanam ro Seongsan gu Changwon si Gyeongsangnam do KOREA This manual is the simplified version of original manual You can obtain the original manual for more information form www lg com VRF FOR INDOOR INSTALLAION ENGLISH PORTUGUÊS MALTI ITALIANO MAGYAR SLOVENČINA РУ...

Страница 2: ...DW H FKDQJHU 0RGXOH XFWLQJ XFWLQJ Total amount of replenishedrefrigerant in refrigerant facility kg Capacity of smallest room whereindoor unit is installed m3 Refrigerant concentration kg m3 Limiting concentration 0 44kg m3 R410A Model Designation Product Name Air conditioner Model Name Product information Additional information Serial number is refer to the bar code on the product Model Name ARU ...

Страница 3: ...jury Do not install remove or re install the unit by yourself customer There is risk of fire electric shock explosion or injury Do not store or use flammable gas or combustibles near the air conditioner There is risk of fire or failure of product Use the correctly rated breaker or fuse There is risk of fire or electric shock Prepare for strong wind or earthquake and install the unit at the specifi...

Страница 4: ... if the unit is so equipped There is risk of physical injury electric shock or product failure CAUTION Installation Always check for gas refrigerant leakage after installation or repair of product Low refrigerant levels may cause failure of product Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods It may cause a problem for your neighbors Ke...

Страница 5: ...g the operational season Do not touch any of the refrigerant piping during and after operation It can cause a burn or frostbite Do not operate the air conditioner with the panels or guards removed Rotating hot or high voltage parts can cause injuries Do not directly turn off the main power switch after stopping operation Wait at least 5 minutes before turning off the main power switch Otherwise it...

Страница 6: ... be no drop in pressure Airtight test Electrical work connection circuits and drive circuits Make sure no gaps are left where the insulating materials are joined Heat insulation work Make sure airflow is sufficient Duct work Adjust to downward gradient Drain pipe work Special attention to dryness cleanness and tightness Refrigerant piping work Check model name to make sure the fitting is made corr...

Страница 7: ...eiving will cause erroneous operations mark in the figure below Only the communication cable specified should be connected to the terminal block for Outdoor Unit communication Supply line of appliances shall not be lighter than polychloroprene sheathed code designation 60245 IEC 57 2 Core Shield Cable Multi Core Cable Remote control Remote control Remote control Remote control Indoor Unit Indoor U...

Страница 8: ...8 ENGLISH 1 MFL69171214 영어 2018 2 23 오후 4 43 페이지 8 ...

Отзывы: