- 8 -
1. Application Object
These instructions are applied to all of the PDP monitor, MP-
00MB.
2. Notes
(1) Because this is not a hot chassis, it is not necessary to use
an isolation transformer. However, the use of isolation
transformer will help protect test instrument.
(2) Adjustment must be done in the correct order.
(3) The adjustment must be performed in the circumstance of
25±5°C of temperature and 65±10% of relative humidity if
there is no specific designation.
(4) The input voltage of the receiver must keep 220/230V,
50/60Hz in adjusting.
(5) The receiver must be operated for about 15 minutes prior
to the adjustment.
¤
After receiving 100% white pattern, the receiver must be
operate prior to adjustment.(Or white condition in HEAT-
RUN mode)
¤Ł
Enter into HEAT-RUN mode
- Select the HEAT-RUN OFF by pressing ADJ button on
Remote Control for adjustment.
- Press the VOL + button in HEAT-RUN OFF.
(OSD display HEAT-RUN WHITE and screen display
100% full WHITE PATTERN)
¤Ø
Set is activated HEAT-RUN without SET TOP BOX or
signal generator in this mode.
[
Single color pattern of HEAT-RUN mode uses to check
PANEL.(RED/BLUE/GREEN)
[Caution] If you turn on a still screen more than 20 minutes, a
afterinage may be occur in the black level part of the
screen.
3. POWER PCB Assy Voltage Adjustment
[
Replace PDP Module or Power Board, adjust certainly Power
PCB Assy Voltage.
3-1. Test Equipment
D.M.M 1EA
3-2. Connection Diagram for Measuring
Refer to Fig 1.
3-3. Adjustment Method
(1) Va Adjusment(Address Voltage Adjusment)
¤
Connect pin 1 of P806 or P811 to (+) jack of D.M.M.
¤Ł
After turning the VR803(Va Adj), voltage of D.M.M
adjustment as same as Va voltage which on label of
panel right/bottom.(Deviation : ±0.5V)
(2) Vs Adjustment
¤
Connect pin 9 of P803 to (+) jack of D.M.M.
¤Ł
After turning the VR804(Vs Adj), voltage of D.M.M
adjust as same as Vs voltage which indicated on label
of panel right/bottom.(Deviation : ±0.5V)
(3) VSC Adjustment
¤
Connect pin 4 of P802 to (+) jack of D.M.M.
¤Ł
After turning the VR806(VSC Adj), voltage of D.M.M
adjust as same as Vs voltage which indicated on label
of panel right/bottom.(Deviation : ±0.5V)
(4) VSETUP Adjustment
¤
Connect pin 1 of P802 to (+) jack of D.M.M.
¤Ł
After turning the VR805(VSETUP Adj),voltage of D.M.M
adjust as same as Vs voltage which indicated on label
of panel right/bottom.(Deviation : ±0.5V)
4. Adjustment of RGB Cut-off and
White Balance
4-1. Required Equipment
Color analyzer(CA-100 or same production)
4-2. Connection Diagram of Equipment for
Measuring
ADJUSTMENT INSTRUCTIONS
V
SETUP
VR806
VR805
VR804
DMM
V
SC
V
A
V
SC
CTL
V
A
CTL
P814
VR803
GND
V
SETUP
CTL
V
S
CTL
V
S
<Fig 1> Connection Diagram of Power Adjustment for Measuring
Refer to Typical Voltage
Va
Vs
Vsc
Vsetup
70V
182V
75V
225V
Address Voltage
Sustain Voltage
Scan Voltage
Setuo Voltage
COLOR
ANALYZER
TYPE; CA-100
Window Pattern
CVBS Signal Input
High Light
120
±
5cd/m2
Low Light
6
±
1cd/m2
PDP MONITOR
MSPG-2100 or
MSTG-5200
<Fig 2> Connection Diagram of Automatic Adjustment
Содержание MT-40PA10S
Страница 15: ...MEMO 15 ...
Страница 18: ... 18 EXPLODED VIEW SET TOP BOX 400 174 410 530 300 550 315 320 330 316 311 310 520 540 ...
Страница 30: ...PRINTED CIRCUIT BOARD MONITOR MAIN TOP STB MAIN TOP MONITOR MAIN BOTTOM STB MAIN BOTTOM ...
Страница 31: ...P No 3854VA0091A S1 1 2 2001 08 30 VSC ...
Страница 32: ...P No 3854VA0091A S1 2 2 2001 08 30 POWER ...
Страница 33: ...P No 3854VA0091A S2 1 2 2001 08 30 RT BA10 ...
Страница 34: ...SVC SHEET 3854V A0091A S1 3854V A0091A S2 ...
Страница 35: ...m ml ...