5-9
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
CAPACITOR
HIGH VOLTAGE
DIODE
NOTE :
Some inexpensive meters
may indicate infinite
resistance in both direction.
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to terminal.
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to case.
Measure the continuity (Forward).
(Ohm-meter scale: Rx10000)
Measure the continuity (Reverse).
(Ohm-meter scale: Rx10000)
Normal: Momentarily indicates
several ohms, and
then gradually returns
to infinite.
Normal: Infinite.
Normal: Continuity.
Abnormal: Infinite.
Normal: Infinite.
Abnormal: Continuity.
NOTE: When testing the magnetron, be sure to install the magnetron gasket
in the correct position and be sure that the gasket is in good condition.
Antenna
Gasket
Chassis
Filament
Содержание MS-3444DPS
Страница 9: ...SCHEMATIC DIAGRAM 4 3 ...
Страница 27: ...DOOR PARTS 6 2 13552A 13213A 13581A 14970A 14026A 13536A 15006A 13551A EV ...
Страница 28: ...CONTROL PANEL PARTS 6 3 23551A 24781M WTP018 268711 24510L 23551B 24970A EV ...
Страница 29: ...OVEN CAVITY PARTS 6 4 33390G WTT010 WTT021 33112U 35889A 36549S WTP013 33052A EV ...
Страница 30: ...LARCH BOARD PARTS 6 5 WSZ085 466001 466003 466001 43500A 43501A EV ...
Страница 32: ...BASE PLATE PARTS 6 7 56170D WSZ002 WTT021 63302A 65006B 63303A 948501 EV ...
Страница 35: ......