5-3
• Microwave power output measurement is made with
the microwave oven supplied at its rated voltage and
operated at its maximum microwave power setting with
a load of (1000 ± 5)g of potable water.
• The water is contained in a cylindrical borosilicate glass
vessel having a maximum material thickness of 3 mm
and an outside diameter of approximately 190 mm.
• The oven and the empty vessel are at ambient
temperature prior to the start of the test.
• The initial temperature (±1) of the water is (10±2)°C. It
is measured immediately before the water is added to
the vessel. After addition of the water to the vessel,
the load is immediately placed on the center of the
turntable which is in the lowest position and the
microwave power switched on.
• The time T for the temperature of the water to rise by a
value
∆
T of (10±2)°K is measured, where T is the time
in seconds and
∆
T is the temperature rise. The initial
and final water temperatures are selected so that the
maximum difference between the final water
temperature and the ambient temperature is 5°K.
• The microwave power output P in watts is calculated
from the following formula:
4187 x (
∆
T)
T
is measured while the microwave generator is
operating at full power. Magnetron filament heat-up
time is not included. (about 3 sec)
• The water is stirred to equalize temperature throughout
the vessel, prior to measuring the final water
temperature.
• Stirring devices and measuring instruments are
selected in order to minimize addition or removal of
heat.
WATER LOAD
TURNTABLE
MEASUREMENT OF MICROWAVE POWER OUTPUT
P =
DISASSEMBLY AND ADJUSTMENT
A. OUTER CASE REMOVAL
1) Disconnect the power supply cord from the outlet.
2) Remove the screws from the rear and along side
edges of the case.
The outer case must be moved backward to be lifted
off.
B. POWER SUPPLY CORD
1) Remove the outer case.
2) Disconnect two terminals, and remove one screw of
the earth terminal.
CAUTION: DISCHARGE THE HIGH VOLTAGE
CAPACITOR BEFORE SERVICING
(refer to page 2-1)
C. CONTROL PANEL ASSEMBLY
1) Disconnect the leadwire from the PCB SUB ASS’Y.
2) Remove the screws for the earth and securing the
control panel.
3) Lift control panel ASS’Y from the oven by the tab
unhooked.
Содержание MS-1983ALB
Страница 29: ...6 2 13581A 14970A 13650A 13552A 13213A 14890A 13551A 13536A WTT028 14026A DOOR PARTS ...
Страница 30: ...6 3 24781M 23551A 23790D 250201 268711 249401 WTP004 CONTROL PANEL PARTS ...
Страница 31: ...6 4 33112U 33390G 35889A 36549S 33052A WTT021 WTT020 WTP013 OVEN CAVITY PARTS ...
Страница 32: ...6 5 43500A 466001 WSZ085 466003 466001 44510A LATCH BOARD PARTS ...
Страница 34: ...6 7 56170D 63302A 65006B 63303A 948502 WSZ002 WTT021 BASE PLATE PARTS ...