5-9
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
CAPACITOR
HIGH VOLTAGE
DIODE
NOTE :
Some inexpensive meters
may indicate infinite
resistance in both direction.
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to terminal.
Measure the resistance.
(Ohm-meter scale: Rx1000)
• Terminal to case.
Measure the continuity (Forward).
(Ohm-meter scale: Rx10000)
Measure the continuity (Reverse).
(Ohm-meter scale: Rx10000)
Normal: Momentarily indicates
several ohms, and then
gradually returns to
infinite.
Normal: Infinite.
Normal: Continuity.
Abnormal: Infinite.
Normal: Infinite.
Abnormal: Continuity.
NOTE: When testing the magnetron, be sure to install the magnetron gasket
in the correct position and be sure that the gasket is in good condition.
Antenna
Gasket
Chassis
Filament
LGE Internal Use Only
Copyright © 2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Содержание MJ3294BDB
Страница 38: ... 6 2 14810C W319 W319 13581A 13651A 13551C W316 W316 14810L 14510L 13213A 13552A 14510L 14810R DOOR PARTS EV ...
Страница 39: ... 6 3 24781S 23572A 26871M 23806C 26871R 23550D CONTROL PANEL PARTS EV ...
Страница 41: ... 6 5 W102 W102 445102 44970A 466001 43500A 466003 466001 43501A 44970A 445101 44980A LATCH BOARD PARTS EV ...
Страница 43: ... 6 7 647781 64970A 64970A 648112 648111 W101 56170D 63302A 63303A BASE PLATE PARTS EV ...
Страница 44: ......