5-15
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Fuse blows.
Continuity.
No continuity.
Continuity.
Shorted contact at
the primary switch.
No continuity.
Normal.
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Fuse blows again
Defective high volt-
age transformer.
Replace high volt-
age transformer.
Malfunction of the
monitor switch.
Check continuity
of monitor
switch (with
door closed).
Check continuity
of primary
switch (with
door opened).
Disconnect one
side of the wire
lead connected
from transformer
to the high
voltage
capacitor and
operate the unit.
Replace fuse
(TROUBLE 2) Oven does not operate at all ; Display window does not display any figures and
no input is accepted.
NOTE : All these switches must be replaced at the same time. Refer to page 5-6, 5-7
2. Fuse does not
blow.
No continuity.
No continuity.
Replace power
supply cord.
Defective mag-
netron thermostat.
Defective power
supply cord.
Replace mag-
netron thermostat.
Check continuity
of magnetron
thermostat.
Check continuity
of power supply
cord.
Continuity.
LGE Internal Use Only
Copyright © 2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Replace defective
Replace defective
switch
switch
Содержание MJ3283BKG
Страница 29: ...5 19 ...
Страница 30: ...5 20 ...
Страница 31: ...5 21 ...
Страница 33: ... 6 2 13581A DOOR PARTS EV 14510L ...
Страница 34: ... 6 3 CONTROL PANEL PARTS EV 24781S ...
Страница 36: ... 6 5 LATCH BOARD PARTS EV 43501A 466003 466003 466001 43500B 568771 ...
Страница 38: ... 6 7 BASE PLATE PARTS EV 64970A 647781 56170D ...
Страница 39: ...7 1 REPLACEMENT PARTS LIST R SERVICE PARTS ...
Страница 40: ......