122
EXTERNAL CONTROL DEVICE SETUP
Communication Parameters
Baud rate : 9600 bps (UART)
Data length : 8 bits
Parity : None
Stop bit : 1 bit
Communication code : ASCII code
Use a crossed (reverse) cable.
Command reference list
Command1
Command2
Data
(Hexadecimal)
01. Power*
k
a
00 to 01
02. Aspect Ratio
k
c
125 page
03. Screen Mute
k
d
126 page
04. Volume Mute
k
e
00 to 01
05. Volume Control
k
f
00 to 64
06. Contrast
k
g
00 to 64
07. Brightness
k
h
00 to 64
08. Color
k
i
00 to 64
09. Tint
k
j
00 to 64
10. Sharpness
k
k
00 to 32
11. OSD Select
k
l
00 to 01
12. Remote Control
Lock Mode
k
m
00 to 01
13. Balance
k
t
00 to 64
14. Color Temperature
k
u
00 to 04
15. Equalizer
j
v
130 page
16. Tune Command
m
a
131 page
17. Channel Add/Del
m
b
00 to 01
18. Key
m
c
KEY CODES
19. Energy Saving
n
p
00 to 02
20. Input select (Main)
x
b
134 page
21. 3D
x
t
134 page
22. Extended 3D
x
v
135 page
23. Auto Configure
j
u
135 page
* Note: During playing media, all commands except Power (ka) and Key
(mc) are not executed and treated as NG.