5-8
CAUTIONS
1. DISCONNECT THE POWER SUPPLY CORD FROM THE OUTLET WHENEVER REMOVING THE
OUTER CASE FROM THE UNIT. PROCEED WITH THE TEST ONLY AFTER DISCHARGING THE HIGH
VOLTAGE CAPACITOR AND REMOVING THE WIRE LEADS FROM THE PRIMARY WINDING OF THE
HIGH VOLTAGE TRANSFORMER. (SEE PAGE 2-1)
2. ALL OPERATIONAL CHECKS WITH MICROWAVE ENERGY MUST BE DONE WITH A LOAD (1 LITER
OF WATER IN CONTAINER) IN THE OVEN.
COMPONENTS
TEST PROCEDURE
RESULTS
HIGH VOLTAGE
TRANSFORMER
(Wire leads removed)
MAGNETRON
(Wire leads removed)
1. Measure the resistance.
(Ohm-meter scale: Rx1 and Rx100)
• Primary winding
• Secondary winding
• Filament winding
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Primary winding to ground
• Filament winding to ground
1. Measure the resistance.
(Ohm-meter scale: Rx1)
• Filament terminal
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Filament to chassis
Approx.: 1.4 ohm
Approx.: 90 ohm
Less than: 1 ohm
Normal: Infinite
Normal: Infinite
Normal: Less than 1 ohm
Normal: Infinite
FILAMENT
WINDING
TERMINAL
SECONDARY
WINDING
PRIMARY
TERMINAL
COMPONENT TEST PROCEDURE
Содержание MH-657PLM
Страница 10: ...SCHEMATIC DIAGRAM 4 4 ...
Страница 30: ...6 2 13581A 13213A 14890A 13552A 13536A 14026A 14970A WTP004 15006A 13720D 13550A 136501 136502 DOOR PARTS ...
Страница 31: ...6 3 26638A 23550A 23806C 24781S 250201 23572A 268712 249401 268711 CONTROL PANEL PARTS ...
Страница 33: ...6 5 466001 43500A 466001 43501A 466003 LATCH BOARD PARTS ...
Страница 35: ...6 7 56170D 63302A WTT021 WTT030 WTT021 WSZ002 647781 63303A BASE PLATE PARTS ...