5-16
CONDITION
CHECK
RESULT
CAUSE
REMEDY
No microwave
oscillation.
No continuity.
Continuity.
Defective P.C.B
assembly
Replace P.C.B
assembly
Disconnect the
wire leads from
relay 2 and
check continuity
of relay2.
(Operate the
unit)
Abnormal
normal
Defective high
voltage
transformer.
Replace high
voltage
transformer .
Check H.V.
transformer.
normal
normal
Abnormal
Defective high
voltage Diode.
Replace high
voltage Diode.
Check H.V.
diode.
Abnormal
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Check H.V.
capacitor.
Abnormal
Defective
magnetron.
Replace
magnetron .
Check
Magnetron.
(TROUBLE 5) No microwave oscillation even though oven lamp and fan motor run
(Display operates properly)
Содержание MH-6072A
Страница 9: ...SCHEMATIC DIAGRAM 4 3 ...
Страница 29: ...6 2 13581A 14970A 14026A 13552A 13213A 13352A 13720D 13650A WTP027 DOOR PARTS ...
Страница 30: ...6 3 23572A 243501 23790D 243502 249401 250202 250201 24781M WTT028 WTP015 268711 CONTROL PANEL PARTS ...
Страница 32: ...6 5 466003 466001 43501A 43500A 44510A 466001 WSZ085 LATCH BOARD PARTS ...
Страница 34: ...6 7 56170D 63302A 63303A WTT021 WSZ002 65006B 948501 BASE PLATE PARTS ...