10. STAND ALONE TEST
- 132 -
10.1 Introduction
This manual explains how to examine the status of RX and TX of the model.
A. Tx Test
TX test - this is to see if the transmitter of the phones is activating normally.
B. Rx Test
RX test - this is to see if the receiver of the phones is activating normally.
10.2 Setting Method
A. COM port
a. Move your mouse on the “Connect” button, then click the right button of the mouse and select “Com
setting”.
b. In the “Dialog Menu”, select the values as explained below.
- Port : select a correct COM port
- Baud rate : 38400
- Leave the rest as default values
B. Tx
1. Selecting Channel
- Select one of GSM or DCS Band and input appropriate channel.
2. Selecting APC
a. Select either Power level or Scaling Factor.
b. Power level
- Input appropriate value GSM (between 5~19) or DCS (between 0~15)
c. Scaling Factor
- A ‘Ramp Factor’ appears on the screen.
- You may adjust the shape of the Ramp or directly input the values.
C. Rx
1. Selecting Channel
- Select one of GSM or DCS Band and input appropriate channel.
2. Gain Control Index (0~ 26) and RSSI level
- See if the value of RSSI is close to -16dBm when setting the value between 0 ~ 26 in Gain Control
Index.
- Normal phone should indicate the value of RSSI close to -16dBm.
10. STAND ALONE TEST
Z3X-BOX.COM
Содержание MG300d
Страница 1: ...Date January 2006 Issue 1 0 Service Manual Model MG300d Service Manual MG300d Z 3 X B O X C O M ...
Страница 23: ...3 TECHNICAL BRIEF 24 Figure 3 1 SKY74400 FUNCTIONAL BLOCK DIAGRAM Z 3 X B O X C O M ...
Страница 48: ...3 TECHNICAL BRIEF 49 3 7 CAMERA IC AIT813 U504 Figure 3 15 AIT813 APPLICATION BLOCKDIAGRAM Z 3 X B O X C O M ...
Страница 50: ...3 TECHNICAL BRIEF 51 3 8 MIDI IC YMU787 U703 Figure 3 24 YMU787 BLOCKDIAGRAM Z 3 X B O X C O M ...
Страница 70: ...4 TROUBLE SHOOTING 71 4 2 TX Trouble SKY74400 FEM 13Mhz OSCILLATOR Test Points Z 3 X B O X C O M ...
Страница 83: ...4 TROUBLE SHOOTING 84 4 6 LCD Trouble EMI FILTER CN600 Test Points Z 3 X B O X C O M ...
Страница 88: ...4 TROUBLE SHOOTING 89 Figure 1_Blue_RST Figure 2_DEBUG_Tx Rx Figure 3_PCM_SYNCS Tx Rx USCO Z 3 X B O X C O M ...
Страница 110: ...5 DOWNLOAD AND CALIBRATION 111 8 Push the START button Z 3 X B O X C O M ...
Страница 111: ...5 DOWNLOAD AND CALIBRATION 112 9 Phone test Finish is shown in below screen Z 3 X B O X C O M ...
Страница 112: ...6 BLOCK DIAGRAM 113 6 BLOCK DIAGRAM Z 3 X B O X C O M ...
Страница 113: ... 114 Z 3 X B O X C O M ...
Страница 124: ... 125 MG300d 8 PCB LAYOUT Z 3 X B O X C O M ...
Страница 125: ... 126 MG300d 8 PCB LAYOUT Z 3 X B O X C O M ...
Страница 133: ...10 STAND ALONE TEST 134 Figure 10 2 HW test setting Figure 10 3 Ramping profile Z 3 X B O X C O M ...
Страница 137: ... 138 Z 3 X B O X C O M ...
Страница 138: ... 139 Z 3 X B O X C O M ...
Страница 140: ... 141 12 EXPLODED VIEW REPLACEMENT PART LIST Z 3 X B O X C O M ...
Страница 141: ... 142 Z 3 X B O X C O M ...