Install the air conditioner in the location that satisfies the fol-
lowing conditions.
• The place shall easily bear a load exceeding four times the
indoor unitʼs weight.
• The place shall be able to inspect the unit as the figure.
• The place where the unit shall be leveled.
• The place shall easily connect with the outdoor unit.
• The place where the unit is not affected by an electrical
noise.
• The place where air circulation in the room will be good .
• There should not be any heat source or steam near the
unit
Confirm the positional relationship between the unit and
suspension bolts.
• Installation the ceiling opening to clean the filter or service
under the product.
Selection of the best location
A(Min)
B(Min)
Ceiling
Service Space
A
B
H
600
(23-5/8)
600
(23-5/8)
Top view
[Unit : mm(inch)]
Front view
Inspection hole
[600(23-5/8) x 600(23-5/8)]
Control box
Capacity(Btu/h)
A
B
7/9/12/15k
600(23-5/8)
900(35-7/16)
18/24k
600(23-5/8) 1,100(43-5/16)
Unit:mm(inch)
Low static Duct type