5-18
(TROUBLE 7) Grill
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Heater is not
operating.
Abnormal.
Normal.
Normal.
Heater.
Thermostat and
relay3.(Grill)
Abnormal.
Malfunction the
thermostat.
Malfunction the
heater.
Replace.
Wire connection.
No continuity.
Open or loosen.
Replace or
connect tightly.
Replace.
1. Lower tempera-
ture the oven.
Abnormal.
Normal.
Heater.
Thermostat and
relay3.(Grill)
Abnormal.
Malfunction the
thermostat.
Malfunction the
heater.
Replace.
Replace.
(TROUBLE 6) Oven does not cook properly when programmed for the set power level
(Operates properly on HIGH)
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Output is full when
you set lower
power level.
Abnormal.
Disconnect the
wire leads from
relay 2 and check
continuity relay 2.
(Operate the unit)
Defective P.C.B.
assembly.
Replace P.C.B.
assembly.
NOTE: * Make sure the wore leads correct position.
* When removing the wire leads from parts be sure to grasp the connector not the wires.
* When removing the magnetron, be sure to install the magnetron gasket in the correct position and in
good condition.
Содержание MC-8083MLR
Страница 9: ...SCHEMATIC DIAGRAM 4 3 ...
Страница 30: ...6 2 15006A 13581A 14970A WTP027 14026A 13552A 13536A 13213A 14890A 13720D 13650A DOOR PARTS ...
Страница 31: ...6 3 24781M 249401 250202 250201 268712 268711 23572A 23790D WTP004 WTP015 CONTROL PANEL PARTS ...
Страница 33: ...6 5 WSZ085 WTT028 43500A 43501A 466001 44510A 466003 466001 WTT028 56912B 55262A 53550L LATCH BOARD PARTS ...
Страница 35: ...6 7 63303A 56170D 63302A 65006B WTT021 WSZ002 BASE PLATE PARTS ...
Страница 36: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Страница 37: ...8 2 PRINTED CIRCUIT BOARD ...
Страница 38: ...P NO 3828W5S3477 Jan 2004 Printed in Korea ...