5-18
(TROUBLE 7) Grill/Convection
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Heater is not
operating.
Abnormal.
Normal.
Normal.
Heater.
Relay
3, 5.
Abnormal.
Malfunction the
relay.
Malfunction the
heater.
Replace.
Wire connection.
No continuity.
Open or loosen.
Replace or
connect tightly.
Replace.
Grill
Control
switch
2. Under or over
cooking in conv.
mode.
Abnormal.
Normal.
Heater.
Thermistor
Abnormal.
Malfunction the
thermistor.
Malfunction the
heater.
Replace.
Replace.
(TROUBLE 6) Oven does not cook properly when programmed for the set power level
(Operates properly on HIGH)
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Output is full when
you set lower
power level.
Abnormal.
Disconnect the
wire leads from
relay 2 and check
continuity relay 2.
(Operate the unit)
Defective P.C.B.
assembly.
Replace P.C.B.
assembly.
NOTE:
* Make sure the wore leads are in the correct position.
* When removing the wire leads from parts be sure to grasp the connector not the wires.
* When removing the magnetron, be sure to install the magnetron gasket in the correct position and in
good condition.
Содержание MC-7684B
Страница 9: ...SCHEMATIC DIAGRAM 4 3 ...
Страница 30: ...6 2 15006A 13552A 14890A 13213A 13720D 14026A 14970A WTP018 13581A 13650A DOOR PARTS EV ...
Страница 31: ...6 3 24781S 23572A 23790D 25020T 25020G 24940P 24940D 25020K 25020S 25020E 268711 WTP004 CONTROL PANEL PARTS EV ...
Страница 33: ...6 5 WSZ085 466001 43501A 466003 466001 44510A 43500A 466001 LATCH BOARD PARTS EV ...
Страница 35: ...6 7 63302A 56170D 63303A WSZ002 WTT021 647781 WTT030 BASE PLATE PARTS EV ...
Страница 36: ......