5-17
(TROUBLE 7) Grill
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Heater is not
operating.
Abnormal.
Normal.
Normal.
Heater.
Thermostat and
relay(Grill).
Abnormal.
Malfunction the
thermostat.
Malfunction the
heater.
Replace.
Wire connection.
No continuity.
Open or loosen.
Replace or
connect tightly.
Replace.
1. Lower tempera-
ture the oven.
Abnormal.
Normal.
Heater.
Thermostat and
relay(Grill).
Abnormal.
Malfunction the
thermostat.
Malfunction the
heater.
Replace.
Replace.
(TROUBLE 6) Oven does not cook properly when programmed for the set power level
(Operates properly on HIGH)
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Output is full when
you set lower
power level.
Abnormal.
Disconnect the
wire leads from
relay 2 and check
continuity relay 2.
(Operate the unit)
Defective P.C.B.
assembly.
Replace P.C.B.
assembly.
NOTE: * Make sure the wore leads correct position.
* When removing the wire leads from parts be sure to grasp the connector not the wires.
* When removing the magnetron, be sure to install the magnetron gasket in the correct position and in
good condition.
Содержание MB-4343C
Страница 9: ...SCHEMATIC DIAGRAM 4 3 ...
Страница 29: ...6 2 13581A 14970A 14026A 13552A 13213A 14890A 13720D 13536A DOOR PARTS ...
Страница 30: ...6 3 23506A 268711 24510L 23572A 250201 24970A WTP018 24781M CONTROL PANEL PARTS ...
Страница 32: ...6 5 466003 466001 43500A 44510A 466001 WSZ085 43501A For Origin Korea LATCH BOARD PARTS ...
Страница 34: ...6 7 56170D 63302A 63303A WTT021 WSZ002 65006B 948501 BASE PLATE PARTS ...
Страница 35: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Страница 36: ...8 2 PRINTED CIRCUIT BOARD ...
Страница 37: ...P NO 3828W5S2961 Jan 2003 Printed in Korea ...