LG MASTER-K10S1 Скачать руководство пользователя страница 8

8

MASTER-K10S1

Relay

Name

Description

F110

Arithmetic error flag

Set when an arithmetic error occurred during operation

F111

Zero flag

Set when the result value is zero

F112

Carry flag

Set when carry / borrow occurs as a result of operation

F11A

On sending flag

These flags indicate the communication status when
DIN / DOUT instructions are used.

F11C

On receiving flag

F11E

Receive completion
flag

F11F

Communication error
flag

• DIN, DOUT: Set when time-out error occurred.

• SEND, RECV : Set when time-out error occurs or

NAK massage is detected.

F122

<

These relays are set according to the result of
compare  instructions. (CMP, CMPP, DCMP, DCMPP)

F123

F120

F121

=

>

F124

F125

F130

~ F135

AC power fail

The numbers of AC power fail occurred during RUN
mode

F140

~ F14F

Elapsed value of
High speed counter

•  HSCNT : The elapsed value of high speed counter is
stored.

• HSC : The low word of elapsed value of high speed
counter is stored.

F150

~ F15F

Preset value of High
speed counter

•  HSCNT : The preset value of high speed counter is
stored.

• HSC : The high word of elapsed value of high speed
counter is stored.

Содержание MASTER-K10S1

Страница 1: ... to the PLC itself only It is not valid for the whole system which the PLC is attached Installation Environment 1 Please avoid installing the PLC at following locations where 2 Please install the PLC at least 50 away from a duct or other devices 3 Be sure to install the PLC in the cabinet which comply with IP54 or higher 4 Be sure to place the PLC in the manufacturer s original packing while shipp...

Страница 2: ... bunches PLC power Insulation Transformer FG noise filter AC power The fuse in the DC power supply may be blown when the DC power is supplied in reverse polarity Be careful to connect power source cable to the correct terminal Internal device of PLC may be damaged by the improper lead connections Supplying power beyond rated voltage frequency may damage internal devices Grounding PLC Other Device ...

Страница 3: ...tructions 30 Basic instructions 154 application instructions Execution time 3 2 7 6 μ s step Program capacity 800 steps Memory device type EEPROM 8kbyte Memory device range P I O relay P000 P007 8points for input P010 P015 6points for output M Auxiliary relay M000 M15F 256points K Keep relay K000 K07F 128points L Link relay L000 L07F 128points F Special relay F000 F15F 256points T 100ms timer T000...

Страница 4: ...east twice larger than the capacity of the load All outputs will be turned off when interruptions of CPU control voltage drops interruptions and or power up down occur Improper terminal connection or overloads on I O may cause a damage on the internal devices Item Input I O Rated Voltage Type Output DC Relay DC24V DC24V AC110 220V On Operating Voltage DC19V Off Operating Voltage DC6V Input Current...

Страница 5: ...D063 T000 T047 T000 T047 C000 C015 C000 C015 S00 S15 Timer Preset Value 48 word Timer Elapsed Value 48 word Counter Preset Value 16 word Counter Elapsed Value 16 word Step Controller 16 X 100 steps S00 00 S15 99 User Program Area 800 Steps 0 F Bit Data Memory Word Data Memory Program Memory Retentive Area K000 K07F L000 L07F T024 T031 T044 T047 C012 C015 D048 D063 S12 00 S15 99 The Integer Setting...

Страница 6: ...the first scan after PGM RUN mode F014 Turnover per each scan Repeat set reset according to each scan during PLC is RUN mode F020 F02F Communication error information Related to SEND RECV instructions only Upper byte The station No where error occurred Lower byte error code The error code of time out error h20 No error h0000 F030 Serious error Set in case of internal ROM error 24V fail error F031 ...

Страница 7: ...RUN mode Example F094 2sec clock F091 100ms clock F092 200ms clock F093 1sec clock F094 2sec clock F095 10sec clock F096 20sec clock F097 1 minute clock F100 F103 User defined clock F100 Clock 0 F103 Clock 3 These relays repeat On Off based on a scan time Initial state Off F060 F06F The step No where error occurred The step No where program error occurred in stored In case of branch instruction er...

Страница 8: ... Set when time out error occurred SEND RECV Set when time out error occurs or NAK massage is detected F122 These relays are set according to the result of compare instructions CMP CMPP DCMP DCMPP F123 F120 F121 F124 F125 F130 F135 AC power fail The numbers of AC power fail occurred during RUN mode F140 F14F Elapsed value of High speed counter HSCNT The elapsed value of high speed counter is stored...

Страница 9: ...9 MASTER K10S1 I O Circuit DC 24V Input COM Input Internal Circuit Relay Output COM Internal Circuit 24V 24V Output External Connection ...

Страница 10: ...ncluding self station Transmission speed 300 19200bps selectable Transmission distance Max 1km no repeater Preset of waiting time Preset address D060 for Time Out Error Preset value x 10ms 0 255 0ms 2550ms Default preset value 0 500ms if preset value is equal or more than 255 waiting time is 2550ms Network System Master PLC Station no h1F Slave PLC1 Slave PLC2 Slave PLC30 RS485 port max 32 station...

Страница 11: ...ord memory device of slave PLC in which data to be transmitted to master is stored D2 Beginning address of word memory device of master PLC in which data to be received from slave will be stored n The number of word data to be transmitted or received Hex or Decimal SEND St S1 D1 n RECV St D2 S2 n Instruction Note When the transmitted data from master PLC is stored to P area of slave directly the o...

Страница 12: ...1 Beijing Branch Beijing LG Industrial Systems Elevator Co Ltd 5F North B D EAS 21 Xiaoyun Road Dongsanhuan Geilu Chaoyang District Beijing 100027 China Tel 86 10 462 3256 Fax 86 10 462 3255 Dalian Branch Dalian LG Industrial Systems Co Ltd A 2005 Hengtong B D 28 Zhigong Road Zhongshan Dist Dalian China Tel 86 411 281 2579 Fax 86 411 281 2578 Taipei Branch LG Industrial Systems Taiwan Co Ltd 3F No...

Отзывы: