ENGLISH
49
EXTERNAL CONTROL DEVICE SETUP (ONLY APPLIED TO B2B MODEL USED IN A PLACE LIKE A HOTEL)
NOTE
RS-232C on this unit is intended to be used
with third party RS-232C control hardware
and software. The instructions below are
provided to help with programming software
or to test functionality using telenet software.
RS-232C connection cables are not supplied
with the product.
EXTERNAL CONTROL DEVICE SETUP (ONLY
APPLIED TO B2B MODEL USED IN A PLACE
LIKE A HOTEL)
RS-232C Setup
Connect the RS-232C (serial port) input jack to
an external control device (such as a computer or
an A/V control system) to control the product’s
functions externally.
Connect the serial port of the control device to the
RS-232C jack on the product back panel.
Type of connector; D-Sub
9-Pin Male
1
5
6
9
RS-232C IN
(CONTROL & SERVICE)
No.
Pin name
1
No connection
2
RXD (Receive data)
3
TXD (Transmit data)
4
DTR (DTE side ready)
5
GND
6
DSR (DCE side ready)
7
RTS (Ready to send)
8
CTS (Clear to send)
9
No Connection