background image

Freezer Fan Error (IF E)

1

2

Open the freezer door and Check
the air flow. Windy?

No

Yes

Go to 3

3

Check the Fan motor.
Rotate fan using hand.
It feel sticky?

Yes

Change the
Fan motor

Reset the unit and
Input Test1 Mode.
(Push the button 1 time)

Go to 4

Fan Motor

TEST MODE 1

Voltage [V]

CON3

10

th 

pin ~ 9

th 

pin  

0V<Voltage<5V

4

Check the Fan Motor voltage
Is Fan Motor voltage  12V?

Yes

Replace
Main PCB

No

TEST MODE 1

Voltage [V]

CON3

12

rth

pin ~ 9

th 

pin  

12V

5

Check the Fan Motor voltage
Is Fan control signal voltage 
between 0V and 5V?

No

Replace
Main PCB

No

7

Explain to customer

CON3

CON3

TEST MODE 1

Voltage [V]

CON3

11

st 

pin ~ 9

th 

pin  

0V<Voltage<5V

Check the Fan Motor voltage
Is Fan feed back voltage 
between 0V and 5V?

No

Replace
Motor

No

CON3

Содержание LXFS28596 Series

Страница 1: ...ation modification copying or transmission of this Service Manual is STRICTLY PROHIBITED unless you have obtained the prior written consent of the LG Electronics entity from which you received this Service Manual The material covered by this prohibition includes without limitation any text graphics or logos in this Service Manual Copyright 2016 2017 LG Electronics Inc All rights reserved Only trai...

Страница 2: ...7 DRAWER REMOVAL 18 4 ADJUSTMENT 19 5 CIRCUIT DIAGRAM 20 6 TROUBLESHOOTING 21 7 PCB PICTURE 22 23 8 TROUBLESHOOTING WITH ERROR DISPLAY 24 37 0 7 7 3 Y A L P S I D R O R R E T U O H T I W G N I T O O H S E L B U O R T 9 10 REFERENCE 71 74 11 COMPONENT TESTING INFORMATION 75 81 12 COMPRESSOR TROUBLESHOOTING 82 91 13 ICEMAKER OPEARTING AND TROUBLE SHOOTING METHOD 92 96 14 DESCRIPTION OF FUNCTION CIRC...

Страница 3: ... 27 7cu ft Fan Cooling Micom Control Full Automatic Heater Defrost PCM Stainless Bar ABS resin Polyurethane Foam SPECIFICATIONS 28 cu ft VEGETABLE TRAY COMPRESSOR EVAPORATOR CONDENSER REFRIGERANT LUBRICATING OIL DEFROSTING DEVICE ITEMS Clear Drawer Type Linear Fin Tube Type Sparial Condenser ISO10 280 ml SHEATH HEATER LED Module 20 LED SPECIFICATIONS LAMP REFRIGERATOR FREEZER DIMENSIONS 146kg 322l...

Страница 4: ...LED interior lamps Crisper Fixed Door Bin Auto Closing Hinge In Door Ice Bin Door in Door Case Adjustable Refrigerator Shelf Glide N Serve Pullout Drawer Durabase and Durabase Divider 4 ...

Страница 5: ...te hinge lever 6 counterclockwise Lift top hinge 7 free of hinge lever latch 8 CAUTION When lifting hinge free of latch be careful that door does not fall forward 7 Place door inside facing up down onto a non scratching surface Right Door FIG 3 1 Open door Loosen top hinge cover screw 1 Lift up cover 2 2 Disconnect door switch wire harness Remove cover 3 Rotate hinge lever 3 clockwise Lift top hin...

Страница 6: ...n up carefully 3 Disconnect wire harness Door Gasket Replacement 1 Insert gasket into channel Press gasket into channels on the four remaining sides of door 2 Insert mullion into the channel Insert the cover assembly into bracket door Mullion Replacement 1 Connect wire harness 3 Assemble 2 screws Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 ...

Страница 7: ... 7 ...

Страница 8: ...fter cutting the Tie Wrap Figure 13 Figure 12 Figure 13 GRILLE ASSEMBLY DEFROST CONTROL ASSEMBLY 3 4 Door Alignment If the space between the door are uneven follow the instructions to align them Remove the Base Grillie Turn the leveling legs counter clock wise to raise or clock wise to lower the height of the front of the refrigerator by using flat blade screw driver or 11 32 wrench Use the wrench...

Страница 9: ... 5 Replace LED assembly 6 Assembly the cover in reverse order 4 Remove the LED assembly from connector LAMP Unplug or disconnect power at the circuit breaker If necessary remove top shelf or shelves Refrigerator Compartment Lamp 1 Pull out cover lamp as using sharp edged tool 2 To remove the LED assembly LED Assembly Figure 17 Figure 14 MULTI DUCT 1 Removethe screw at the Center of Duct Multi 2 Re...

Страница 10: ...1 0 3 8 MAIN PWB 1 Loosen 3 screws on the PWB cover 2 Remove the PWB cover 3 Disconnect wire harness and replace the main PWB in the reverse order of removal 3 9 DISPLAY PCB Figure 20 Figure 21 Figure 22 ...

Страница 11: ...hinge with one hand 3 Pull out the Ice Corner Door with the other hand hinge 3 11 ICEMAKER REPLACEMENT 1 Remove 4 screws as shown 2 Grasp the bottom of motor cover assembly and pull slowly 3 Disconnect wire harness from wall of compartment Figure 32 Figure 33 Figure 34 Motor DC Assembly Indoor Figure 35 ...

Страница 12: ... duct and the link for proper fit Link Duct Door Cap Duct Motor NG Position 2 Unscrew 3 screws to disassemble the motor 4 Insert 2 screws 5 Push housing aside CAUTION Make sure that the motor housing is taped to the mold if not positioned correctly the cover will not fit properly Figure 36 Figure 43 Figure 42 Figure 41 Figure 40 Figure 39 ...

Страница 13: ... handles as shown 2 Tilt and lift slightly as shown 3 18 HOW TO INSERT A ICE BIN 1 Insert the Ice Bin slightly tilting to avoid touching the Icemaker Especially Ice Detecting Sensor 3 Remove ice bin slowly Figure 44 Figure 45 Figure 46 Figure 47 ...

Страница 14: ...from the guide rails one from each side Step 2 Remove the lower basket Step 4 Removal of the freezer door is done by lifting clear of the rail support Fully extend both rails Step 6 Remove 2 screws of both side of supporter covers tv and disassemble the supporter cover tv Step 5 Remove only 1 screw of gearice and disassemble the bar and gearice ...

Страница 15: ... Reinstall the freezer door by inserting the rail tabs into the guide rail Step 8 Reinstall the lower basket and close the freezer door Step 5 The rail system will align itself by pushing the rails all the way into the freezer section Pull the rails back out to full extension Step 7 Reinstall the two screws into the guide rails one from each side Step 2 Assemble a bar and gear ice with screw Push ...

Страница 16: ... from the valve 2 Remove cover and 1 screw from the valve 3 Separate the housing and remove the valve 4 Remove the clip and press the collet to separate the tube from the connector Note there maybe some water in the line Mechanical Cover Housing Figure 60 Figure 61 Figure 62 Figure 63 3 22 ...

Страница 17: ...7 3 23 Drawer Removal Fully extend the drawer and lift from the front pulling straight out To install the drawer back into the frame tilt the front sightly and pushingt back into place Figure 66 Figure 67 ...

Страница 18: ...ox 1 While the refrigeration chamber doors are open wide remove all of the Magic Space cover and shelves Refer to page 27 28 2 Remove left right side vegetable chambers 3 Support the bottom of the shelf with one hand and hold the front of the vegetable chamber with the other hand and pull forward about 3cm while lifting the chamber so that the inner side fixing part can be taken out Leftside e p y...

Страница 19: ...e h t n e p O 1 2 Remove the gasket from gasket channel at doorliner as shown in the illustration below 4 Using the lever principle Insert the Small Screw Driver applies a force to hole 5 Disconnect wire harness 3 Remove a Screw 6 Remove a screw Gasket Channel Gasket 1 9 ...

Страница 20: ...sitively necessary 2 Tighten a screw to the cover 4 1 Push the flat screwdriver in the rear of the LED lamp and take the lamp out from the hook 2 Disassemble the combined housing with the flat screwdriver 3 You should take LED lamps out and pull from the right 3 Pull a screw using a Plier and disassemble the cover 2 0 ...

Страница 21: ...For every 416 7us check whether FO signal is LOW The trip occurs if it is found three times during the five periods 83ms 4 ADJUSTMENT 4 1 1 Role 4 1 COMPRESSOR The compressor intakes low temperature and low pressure gas from the evaporator of the refrigerator and compresses this gas to high temperature and high pressure gas It then delivers the gas to the condenser 4 1 2 Note for Usage 1 Be carefu...

Страница 22: ...H WH 18 19 20 21 22 SB BK PR RD 23 PR WH 24 25 YL WH GY YL 27 29 BN WH PK BO BL WH BK YL RD 31 26 28 30 32 33 34 BETA DUCT HEATER REFRIGERATOR STEPPING MOTOR BETA DU CHAUFFAGE CON3 WH RD GY GY RD PK BO PR GY WH BO BL RD YL BN WH YL WH YL BK BK SB WH BL RD BO WH PR WH YL BL SB 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 34 CON61 1 BK 2 BL RD 3 YL 4 RD 5 PR WH 7 6 BL WH RD WH RD WH B...

Страница 23: ...gF Error of flow meter or water input or low water pressure Error of flow meter or water input or low water pressure or flow meter connection 11 Abnormality of BLDC FAN Motor for Ice Making IF It is caused when feedback signal isn t over 65 seconds during BLDC FAN motor operating Poor BLDC Motor connection DRIVE IC and TR 12 Abnormality of BLDC FAN Motor for Freezer FF It is caused when feedback s...

Страница 24: ... P N EBR841464 7 PCB Picture 7 1 Main PCB 7 2 Display PCB P N EBR860937 CON102 CON101 CON103 CON802 CON1 CON201 CON61 CON7 CON4 CON6 CON5 CON3 CON71 2 4 ...

Страница 25: ... P N EBR764684 7 PCB Picture 7 3 Sub PCB Con1 Con2 P N EBR640311 7 4 Sub PCB CON2 CON1 CON4 CON5 2 5 ...

Страница 26: ... a loose connection 2 Check Sensor Resistance 8 Trouble Shooting 8 1 Freezer Sensor Error FS E Resistance CON5 12th pin 11th pin Short 0 Open OFF Other Normal CON5 12th pin 11th pin Resistance 22ºF 30ºC 40k 13ºF 25ºC 30k 4ºF 20ºC 23k 5ºF 15ºC 17k 14ºF 10ºC 13k 23ºF 5ºC 10k 32ºF 0ºC 8k 2 6 ...

Страница 27: ... No Change the Sensor 3 Check the Sensor resistance Is resistance OFF Sensor open Yes No Replace the refrigerator 4 Check the Sensor resistance Is resistance normal Yes 5 Check the Temperature and resistance refer to the table No problem Yes CON5 12th pin 11th pin Resistance 22ºF 30ºC 40k 13ºF 25ºC 30k 4ºF 20ºC 23k 5ºF 15ºC 17k 14ºF 10ºC 13k 23ºF 5ºC 10k 32ºF 0ºC 8k 6 Explain to customer CON5 2 7 ...

Страница 28: ...or Resistance 8 2 Refrigerator Sensor Error rS E Resistance CON5 18th pin 17th pin Short 0 Open OFF Other Normal CON5 18th pin 17th pin Resistance 23ºF 5ºC 38k 32ºF 0ºC 30k 41ºF 5ºC 24k 50ºF 10ºC 19 5k 59ºF 15ºC 16k CON1 CON201 CON61 CON7 CON4 CON6 CON5 CON3 CON71 R R 2 8 ...

Страница 29: ...ensor short Yes No Change the Sensor 3 Check the Sensor resistance Is resistance OFF Sensor open Yes No Replace the refrigerator 4 Check the Sensor resistance Is resistance normal Yes 5 Check the Temperature and resistance refer to the table No problem Yes 6 Explain to customer CON5 18th pin 17th pin Resistance 23ºF 5ºC 38k 32ºF 0ºC 30k 41ºF 5ºC 24k 50ºF 10ºC 19 5k 59ºF 15ºC 16k CON5 2 9 ...

Страница 30: ...ction 2 Check Sensor Resistance Resistance CON101 1st pin 2ndpin Short 0 Open OFF Other Normal 8 3 Icing Sensor Error IS E CON101 1st pin 2ndpin Resistance 22ºF 30ºC 40k 13ºF 25ºC 30k 4ºF 20ºC 23k 13ºF 25ºC 17k 14ºF 10ºC 13k 23ºF 5ºC 10k 32ºF 0ºC 8k 3 0 ...

Страница 31: ...Yes No Change the Sensor 3 Check the Sensor resistance Is resistance OFF Sensor open Yes No Replace the refrigerator 4 Check the Sensor resistance Is resistance normal Yes 5 Check the Temperature and resistance refer to the table No problem Yes 6 Explain to customer CON101 1st pin 2ndpin Resistance Ω 22ºF 30ºC 40k 13ºF 25ºC 30k 4ºF 20ºC 23k 13ºF 25ºC 17k 14ºF 10ºC 13k 23ºF 5ºC 10k 32ºF 0ºC 8k ...

Страница 32: ...ensor Resistance 8 4 Defrost Sensor Error dS F Resistance Ω CON5 10th pin 9th pin Short 0 Open OFF Other Normal CON5 10th pin 9th pin Resistance Ω 23ºF 5ºC 38k 32ºF 0ºC 30k 41ºF 5ºC 24k 50ºF 10ºC 19 5k 59ºF 15ºC 16k CON1 CON201 CON61 CON7 CON4 CON6 CON5 CON3 CON71 R R ...

Страница 33: ...sistance Is resistance 0Ω Sensor short or resistance Infinity Ω Sensor open Yes No Change the Sensor 3 Check the Sensor resistance Is resistance normal Yes 4 Check the Temperature and resistance refer to the table No problem Yes 5 Explain to customer CON5 10th pin 9th pin Resistance Ω 23ºF 5ºC 38k 32ºF 0ºC 30k 41ºF 5ºC 24k 50ºF 10ºC 19 5k 59ºF 15ºC 16k Change Main PCB No CON5 ...

Страница 34: ...Symptom Check Point 1 It E 1 Check the Ice maker rotation 2 Check the motor voltage 8 5 Ice Maker Motor Error It E CON 5 CON 2 CON 4 CON 1 1 Pin1 2 Pin5 3 Pin8 CON 5 CON 5 ...

Страница 35: ...V Yes OR Change the Ice maker kit 3 Check the ice maker reverse status The voltage 1 3 point 11 12V Yes Change the Ice maker kit 4 Check the ice maker forward status The voltage 1 2 point 0V Yes Change the Main PCB 5 Check the ice maker reverse status The voltage 1 3 point 0V Yes No Change the Main PCB OR OR CON 5 1 Pin1 2 Pin5 2 3 Pin8 CON 5 1 Pin1 2 Pin5 2 3 Pin8 CON 5 1 Pin1 2 Pin5 3 Pin8 CON 5...

Страница 36: ...3 Check the PCB output voltage Part Resistance FUSE M 0 Defrost Heater 34 42 Defrost Sensor 22k 8 6 Defrost Heater Error dH F TEST MODE 3 Voltage V CON7 6th pin 12th pin 112V 116V TEST MODE 1 Voltage V CON7 6th pin 12th pin 0V CON1 CON201 CON61 CON7 CON4 CON6 CON5 CON3 CON71 CON5 CON 7 ...

Страница 37: ...es Change Defrost Heater 4 Check the Heater Voltage Is voltage 112V 116V Yes 3 Check the Defrost control part Is Defrost Sensor resistance 22k or OFF OFF 22k Replace product Input Test 3 Mode Push the button 3 times Replace Main PCB NO TEST MODE 3 Voltage V CON7 6th pin 12th pin 112V 116V 5 Check the Heater Voltage Is voltage 0V Yes Input Test 1 Mode Push the button 1 times Replace Main PCB No 6 E...

Страница 38: ...Check the Fan Motor 3 Check the PCB Fan motor voltage 8 7 Freezer Fan Error FF E TEST MODE 1 Voltage V CON7 8th pin 5th pin 12V CON7 6th pin 5th pin 0V Voltage 5V CON7 7th pin 5th pin 0V Voltage 5V CON1 CON201 CON61 CON7 CON4 CON6 CON5 CON3 CON71 CON 3 ...

Страница 39: ...sticky Yes Change the Fan motor Replace Main PCB No Reset the unit and Input Test1 Mode Push the button 1 time Go to 4 Fan Motor TEST MODE 1 Voltage V CON7 8thpin 5th pin 12V 5 Check the Fan Motor voltage Is Fan control signal voltage between 0V and 5V No Replace Main PCB No 7 Explain to customer CON3 CON3 TEST MODE 1 Voltage V CON7 7th pin 5th pin 0V Voltage 5V Check the Fan Motor voltage Is Fan ...

Страница 40: ...heck the Connector 3 Check the PCB Fan motor voltage 8 8 Icing Fan Error IF E TEST MODE 1 Voltage V CON3 12rthpin 9th pin 12V CON3 10th pin 9th pin 0V Voltage 5V CON3 11st pin 9th pin 0V Voltage 5V CON1 CON201 CON61 CON7 CON4 CON6 CON5 CON3 CON71 CON 3 ...

Страница 41: ...E 1 Voltage V CON3 10th pin 9th pin 0V Voltage 5V 4 Check the Fan Motor voltage Is Fan Motor voltage 12V Yes Replace Main PCB No TEST MODE 1 Voltage V CON3 12rthpin 9th pin 12V 5 Check the Fan Motor voltage Is Fan control signal voltage between 0V and 5V No Replace Main PCB No 7 Explain to customer CON3 CON3 TEST MODE 1 Voltage V CON3 11st pin 9th pin 0V Voltage 5V Check the Fan Motor voltage Is F...

Страница 42: ...the Connector 3 Check the PCB Fan motor voltage 8 9 Condenser Fan Error CF E Fan Motor TEST MODE 1 Voltage V CON3 4th pin 1st pin 12V CON3 2nd pin 1st pin 0V Voltage 5V CON3 3rd pin 1st pin 0V Voltage 5V CON1 CON201 CON61 CON7 CON4 CON6 CON5 CON3 CON71 CON 3 ...

Страница 43: ...E 1 Voltage V CON3 2nd pin 1st pin 0V Voltage 5V 4 Check the Fan Motor voltage Is Fan Motor voltage 12V Yes Replace Main PCB No TEST MODE 1 Voltage V CON3 4th pin 1st pin 12V 5 Check the Fan Motor voltage Is Fan control signal voltage between 0V and 5V No Replace Main PCB No 7 Explain to customer TEST MODE 1 Voltage V CON3 3rd pin 1st pin 0V Voltage 5V Check the Fan Motor voltage Is Fan feed back ...

Страница 44: ...Check the Hinge connection 8 10 Communication Error CO E Voltage V CON101 7th pin 6th pin 12V CON101 5th pin 6th pin Not 0V 5V CON101 4th pin 6rd pin Not 0V 5V CON5 3th pin 6th pin 5V CON1 CON201 CON61 CON7 CON4 CON6 CON5 CON3 CON71 CON 6 Display CON101 CON101 ...

Страница 45: ...oltage Is CON101 5th pin 6th pin voltage 0V or 5V Yes No Housing Voltage V CON101 5th pin 6th pin Not 0V 5V Change the Main PCB 4 Check the voltage Is CON101 4th pin 6th pin voltage 0V or 5V Yes No Housing Voltage V CON101 4th pin 6th pin Not 0V 5V Change the Display PCB 5 Check the voltage Is CON6 8th pin 9th pin voltage 0V or 5V Yes No Housing Voltage V Not 0V 5V Change the Main PCB 6 Check the ...

Страница 46: ...Symptom Check Point 1 Cube mode doesn t work 1 Check the loose connection 2 Check the resistance 8 11 Cube mode doesn t work Dispenser Assembly Ice Dispenser Motor CON1 CON2 Geared Motor ...

Страница 47: ...mode doesn t work Resistance Ω CON1 17th pin 19th pin 17th pin 21th pin 19th pin 21th pin 2 55 7 Voltage V CON1 2nd pin 6th pin 24V 10 Pushing The LEVER S W Voltage V CON1 20th pin 6th pin 14th pin 6th pin 5V 10 ...

Страница 48: ... Value No Yes Change the PCB Assembly Main Loc 500A CON6 4th pin 3th pin Voltage V 24V 24V 10 Check the Ice Bucket CON1 17th pin 19th pin 17th pin 21th pin 19th pin 21th pin Geard Motor 1st pin 2ndpin 2nd pin 3th pin 1st pin 3th pin Resistance Ω U V W 2 55 7 No Yes CON1 2nd pin 6th pin Voltage V 24V 24V 10 While pushing the lever S W is voltage correct No Sub PCB Voltage NG or When Main PCB Voltag...

Страница 49: ...Symptom Check Point 1 Crush mode doesn t work 1 Check the loose connection 2 Check the resistance 8 12 Crush mode doesn t work CON1 CON2 Dispenser Assembly Ice Dispenser Motor Geared Motor ...

Страница 50: ... mode doesn t work Resistance Ω CON1 17th pin 19th pin 17th pin 21th pin 19th pin 21th pin 2 55 7 Voltage V CON1 2nd pin 6th pin 24V 10 Pushing The LEVER S W Voltage V CON1 20th pin 6th pin 14th pin 6th pin 5V 10 ...

Страница 51: ... Value No Yes Change the PCB Assembly Main Loc 500A CON6 4th pin 3th pin Voltage V 24V 24V 10 Check the Ice Bucket CON1 17th pin 19th pin 17th pin 21th pin 19th pin 21th pin Geard Motor 1st pin 2ndpin 2nd pin 3th pin 1st pin 3th pin Resistance Ω U V W 2 55 7 No Yes CON1 2nd pin 6th pin Voltage V 24V 24V 10 While pushing the lever S W is voltage correct No Sub PCB Voltage NG or When Main PCB Voltag...

Страница 52: ...doesn t work 1 Check the loose connection 2 Check the resistance valve 8 13 Water mode doesn t work LEVER S W Voltage V CON2 11th pin Neutral Pushing 112 115V Not Pushing 0 2V Resistance Ω Pilot Valve 360 420 Water valve 360 420 CON2 A ...

Страница 53: ...he PCB 3 Check the resistance value Is Pilot Valve resistance 360 420 Ω No Yes Replace Water Valve Pilot Valve Resistance Ω Pilot Valve 360 420 4 Check the resistance value Is Water Valve resistance 360 420 Ω No Yes Replace Water Valve Water Valve Resistance Ω Water valve 360 420 A LEVER S W Voltage V CON2 11th pin Neutral Pushing 112 115V Not Pushing 0 2V ...

Страница 54: ... Refrigerator door switch sticky 2 Check the door S W resistance 3 Check the LED Lamp 8 14 Refrigerator room lamp doesn t work S W Resistance Ω Door Open Infinity Close 0 Voltage V CON5 8th pin 7th Pin 12V Door S W LED Lamp Voltage V White Yellow Closed 0 2V Open 12V R R ...

Страница 55: ...ltage V CON5 8th pin 7th Pin 12V 2 Check the door S W resistance Is it correct compared with table No Yes Change the Door S W Door S W 3 Check the PCB Voltage Is CON7 33th pin 34th pin voltage 12V No Yes Change the PCB 4 Check the LED Lamp voltage Is it 0 2V While door closed No Yes Change the Door S W 5 Check the LED Lamp voltage Is it 12V While door open No Yes Change the LED Lamp CON5 ...

Страница 56: ...or switch sticky 2 Check the door S W resistance 3 Check the LED Lamp 8 15 Freezer room upper lamp doesn t work S W Resistance Ω Door Open Infinity Close 0 Voltage V CON3 14th pin 13th Pin 12V F Door LED Lamp Voltage V Open White Black 12V Close White Black 0 2V F U LED PCB Door S W ...

Страница 57: ... the LED Lamp voltage Is voltage 12V While door open No Yes Change the LED Lamp Voltage V CON3 14th pin 13th Pin 12V 2 Check the door S W resistance Is it correct compared with table No Yes Change the Door S W Door S W 3 Check the PCB Voltage Is CON3 14th pin 13th pin voltage 12V No Yes Change the PCB S W Resistance Ω Door Open Infinity Close 1 ...

Страница 58: ... Damper motor voltage 8 16 Poor cooling in Fresh food section CON5 18th pin 17th Pin Resistance Ω 23ºF 5ºC 38k 32ºF 0ºC 30k 41ºF 5ºC 24k 50ºF 10ºC 19 5k 59ºF 15ºC 16k Duct Status Air Flow Windy Air Temperature Cold Duct Fan Motor TEST MODE 1 Voltage V CON3 8th pin 5th Pin 12V CON5 6th pin 5th Pin 0V Voltage 5V CON5 7th pin 5th Pin 0V Voltage 5V R R ...

Страница 59: ...d door and Check the air flow Damper No Yes Check the damper Go to 5 4 Check the air temperature Is it cold No Yes Check the Compressor and sealed system 5 Check the Fan Motor voltage Is Fan Motor voltage right Yes Replace Main PCB No 6 Check the Fan Motor voltage Is Fan Feed Back voltage 0V 5V No Change the motor Yes Go to 7 TEST MODE 1 Voltage V CON3 8th pin 5th Pin 12V CON5 7th pin 5th Pin 0V V...

Страница 60: ...the Fan motor voltage 8 17 Poor cooling in Freezer compartment Duct Fan Motor CON5 12th pin 11th Pin Resistance Ω 22ºF 30ºC 40k 13ºF 25ºC 30k 4ºF 20ºC 23k 13ºF 25ºC 17k 14ºF 10ºC 13k 23ºF 5ºC 10k 32ºF 0ºC 8k TEST MODE 1 Voltage V CON3 8th pin 5th Pin 12V CON5 6th pin 5th Pin 0V Voltage 5V CON5 7th pin 5th Pin 0V Voltage 5V Duct Status Air Flow Windy Air Temperature Cold R R ...

Страница 61: ... 1 Check the sensor resistance 3 Open the fresh food door and Check the air flow Windy No Yes Check the F Fan Motor Go to 5 4 Check the air temperature Is it cold No Yes Check the Compressor and sealed system 5 Check the Fan motor Rotate fan using hand It feel sticky Yes Change the Fan motor Fan Motor No 2 Reset the unit and Input Test1 Mode Push the button 1 time ...

Страница 62: ...eplace Main PCB No 7 Check the Fan Motor voltage Is Fan Feed Back voltage right Yes Change the motor No 8 Explain to customer TEST MODE 1 Voltage V CON3 8th pin 5th Pin 12V CON5 7th pin 5th Pin 0V Voltage 5V TEST MODE 1 Voltage V CON5 6th pin 5th Pin 0V Voltage 5V ...

Страница 63: ...k the Fan motor voltage 8 17 Over cooling in Freezer compartment Duct Fan Motor CON5 12th pin 11th Pin Resistance Ω 22ºF 30ºC 40k 13ºF 25ºC 30k 4ºF 20ºC 23k 13ºF 25ºC 17k 14ºF 10ºC 13k 23ºF 5ºC 10k 32ºF 0ºC 8k TEST MODE 1 Voltage V CON3 8th pin 5th Pin 12V CON5 6th pin 5th Pin 0V Voltage 5V CON5 7th pin 5th Pin 0V Voltage 5V Duct Status Air Flow Windy Air Temperature Cold ...

Страница 64: ...2ºF 0ºC 8k Over cooling in Freezer compartment 1 Check the sensor resistance 2 Check the air flow in test mode 1 3 Push the button 1 or 3 time 3 Check the Fan motor Rotate fan using hand It feel sticky Yes Change the Fan motor Fan Motor No 4 Change the Main PCB Test1 Air Flow Test3 No Air Flow NG OK Explain to customer ...

Страница 65: ... not work 1 Check the Main PCB 2 Check the Home Bar Heater Part Resistance Ω Defrost Heater 1912 2314 8 18 Home Bar Heater do not work TEST MODE 3 Voltage V CON7 10th pin 3th Pin 112V 116V TEST MODE 1 Voltage V CON7 10th pin 3th Pin 0V ...

Страница 66: ...onnect the housing 4 Check the Heater Voltage Is voltage 112 116V Yes 3 NO Change The door Input Test 3 Mode Push the button 3 times Replace Main PCB NO TEST MODE 3 Voltage V CON7 10th pin 3th Pin 112V 116V 5 Check the Heater Voltage Is voltage 0V Yes Input Test 1 Mode Push the button 1 times Replace Main PCB No 6 Explain to customer Check Heater part Heater resistance 1912 2314 Ω Yes ...

Страница 67: ...do not work 1 Check the Main PCB 2 Check the Home Bar Heater Part Resistance Ω Defrost Heater 1912 2314 8 19 GID Heater do not work TEST MODE 3 Voltage V CON7 11th pin 3th Pin 112V 116V TEST MODE 1 Voltage V CON7 11th pin 3th Pin 0V ...

Страница 68: ...nect the housing 4 Check the Heater Voltage Is voltage 112 116V Yes 3 NO Change The door Input Test 3 Mode Push the button 3 times Replace Main PCB NO TEST MODE 3 Voltage V CON7 11th pin 3th Pin 112V 116V 5 Check the Heater Voltage Is voltage 0V Yes Input Test 1 Mode Push the button 1 times Replace Main PCB No 6 Explain to customer Check Heater part Heater resistance 3072 3534 Ω Yes ...

Страница 69: ...Symptom Check Point 1 Hygiene fan doesn t work 1 Check Hygiene Fan motor voltage 2 Main PCB 8 20 Hygiene fan doesn t work Voltage V CON5 2th pin 1th Pin 12V Hygiene Fan motor R R ...

Страница 70: ...PCB 3 Check the Hygiene voltage Is voltage 12V While door open No Yes Change the Fan motor Voltage V CON5 2th pin 1th Pin 12V 2 Is the connector loose Yes No Connect the housing Choose the Hygiene Max in display Check the PCB Voltage Is CON6 2nd pin 5th pin voltage 12V ...

Страница 71: ...esn t work 1 Check connector 2 Display PCB 3 Wi Fi modem PCB 8 20 Wi Fi modem doesn t work Wi Fi ON Voltage V CON802 1st pin 4th pin 5V CON802 2nd pin 4th pin Not 0V 5V CON802 3rd pin 4th pin Not 0V 5V Display PCB CON802 CON802 Wi Fi PCB ...

Страница 72: ...i Fi function is on No Yes Change the display 2 Check the Wi Fi PCB output While Wi Fi function is on No Yes Choose the connectors in the display and lead wire Is it loose Wi Fi modem Voltage V 5th pin 6th pin Not 0V 5V Change Wi Fi modem Display CON802 Voltage V 1st pin 4th pin 5V 2nd pin 4th pin Not 0V 5V CON802 ...

Страница 73: ...PA 1 How to enter the TEST MODE Push the test button on the Main PCB to enter the TEST MODE 2 How to remove Terminal Position Assurance TPA 1 time Comp Damper All FAN on Everything is displayed 2 times Damper closed 22 22 displayed 3 times Forced defrost mode 33 33 displayed Main PWB A P T C D A P T C A ...

Страница 74: ...F 5 C 32 F 0 C 41 F 5 C 50 F 10 C 59 F 15 C 68 F 20 C 77 F 25 C 86 F 30 C 95 F 35 C 104 F 40 C RESISTANCE 73 29 53 63 39 66 29 62 22 33 16 99 13 05 10 10 7 88 6 19 4 91 3 91 3 14 2 54 2 07 1 69 1 39 VOLTAGE 4 09 V 3 84 V 3 55 V 3 23 V 2 89 V 2 56 V 2 23 V 1 92 V 1 63 V 1 38 V 1 16 V 0 97 V 0 81 V 0 67 V 0 56 V 0 47 V 0 39 V ...

Страница 75: ... C 32 F 0 C 41 F 5 C 50 F 10 C 59 F 15 C 68 F 20 C 77 F 25 C 86 F 30 C 95 F 35 C 104 F 40 C RESISTANCE 225 1 169 8 129 3 99 30 76 96 60 13 47 34 37 55 30 24 13 19 53 15 91 13 03 10 74 8 89 7 40 6 20 VOLTAGE 4 48 V 4 33 V 4 16 V 3 95 V 3 734 V 3 487 V 3 22 V 2 95 V 2 67 V 2 40 V 2 14 V 1 89 V 1 64 V 1 45 V 1 27 V 1 10 V 0 96 V ...

Страница 76: ...here is a fan motor malfunction this process is repeated 3 times If the fan motor is determined to be defective the error code will be shown in the display for 30 minutes At this point the process will be repeated until the fan motor operates normally If normal operation is achieved the error display is erased and the MICOM is reset automatically No signal Error Display 15s 10s 15s 10s 15s Normal ...

Страница 77: ...t a ohmmeter to the 2 housing pin Measure the 2 pin connected to Fuse M If the ohmmeter indicate below 0 1ohm fuse m is a good condition But if infinite the part is bad How to Measure Sensor Set a ohmmeter to The 2housing pin Measure the 2 pin connected to Sensor If the ohmmeter indicate 11 at room temperature Sensor is good When check the ohm at other temperatures Check the sensor manual Standard...

Страница 78: ...resistance How to Measure Set a ohmmeter connect to The 2 housing pin Measure the 2 pin connected to Sheath Heater If the ohmmeter indicate V øV Watt R is good condition ex when watt 350w voltage 115v R 115 ø115 350 38 But if the ohm meter indicate infinity the Sheath heater is bad Standard Sheath heater at all temperature Test Point 1 to 2 Ressult 34 42 1 2 ...

Страница 79: ... 79 11 3 Door Heater Assembly 1 9 2 2KΩ ...

Страница 80: ... DC Motor Function Dispenser DC Motor When customer push the dispenser button Pull duct door and abstract from ice bank How to Measure Standard Dispensor DC Motor Dispenser DC Motor Test Points 1 to 2 Result 9 9 12 1 1 2 ...

Страница 81: ... the damper is closed the chill rooms temperature will rise How to Measure Damper Circuit extension Check the Standard Damper Test Points Red and Yellow Result 373 456 Test Points Blue and White Result 373 456 Check to see if there is electrical current if there is resistance the damper is good 1 Blue 3 White 1 3 Check the 1 2 Check the 3 4 1 BLUE 2 WHITE 3 YELLOW 4 RED ...

Страница 82: ...ensor Function Flow Sensor in machine room Count the water quantity from city water to water filter in refrigerator How to Measure Standard Flow Sensor in machine room Test Points Red wire to Black wire Result 4 30 k ...

Страница 83: ...LED 4 Blinks About 5min Reset Reset Reset Reset Reset Reset Reset Test Mode 1 Input Test Mode 1 Input Test Mode 1 Input Test Mode 1 Input Test Mode 1 Input Test Mode 1 Input Test Mode 1 Input Test Mode 1 Input PCBA Output 60V Replace PCB Replace PCB Y N Y N LED Trip Information 1 Current Voltage Sensing Error 2 Over Stroke 3 Comp Connection Error 4 Over Voltage Error 5 Comp Lock Error 6 Over Curre...

Страница 84: ... the COMP off every 1 minute restart COMP PCBA output 60 V N LED 2 Blinks Operate COMP Y Harness Wiring Y Repair Harness N LED 2 Blinks Check COMP Check Cycle leakage About 5min Reset Test Mode 1 Input Replace PCB Y N 2 Stroke Trip and LED Blinking 2 times Stroke Trip 3 No Connection Trip And LED Blinking 3 times No Connection Trip Purpose Prevention Over Voltage and Over Current by detecting conn...

Страница 85: ...to do per LED Blinking and Trip protection Logic 5 Lock Piston Trip and LED Blinking 5 times Locked Piston Purpose Detect locked piston Cause Oil shortage of the cylinder Cylinder or Piston damage clogging the discharge Comp internal debris Logic After the Comp Off every 2 min 30 seconds restart Comp Blink OFF BlinkBlinkBlinkBlink Check the Protection Logic Check the L Piston or LED blinking 5 tim...

Страница 86: ...r N Reset Y Current trip occur Check the leakage and cycle Recheck Check the PCB output Y Replace PCB N N N N Y Replace Compressor Repair Sealed system Y Do not operate Comp Clogging the Cycle N Y 7 IPM Fault Trip and LED Blinking 7 times IPM Fault Purpose Protection Over Current by failure IPM IPM short Cause IPM Short and failure Logic After the Comp Off every 20 seconds restart Comp Blink OFF B...

Страница 87: ...mpressor Harness 1 Check the Harness connection 2 Check the Compressor Power off Check the Resistance point A Harness Connection OK A B Connection error Check the Resistance point B Check the Resistance point D Replace Compressor B D Connection error Check the Harness Y N N Y Y Y N N Check Comp terminal Harness failure Y N Step 1 Power off Step 2 Check the Resistance point A Step 3 Check the Harne...

Страница 88: ...e measurement Check the insulation break down Multi Tester Co Sa Po Sa Save Po Power Co Common Point A Point B Point D Multi Tester Multi Tester Multi Tester The resistance can differ by few Ω depending on the surrounding temperature or operating condition Earth Hermetic terminal Mode Resistance Power 5 1Ω 6 3Ω Save 8 5Ω 10 4Ω FLD165NBMA ...

Страница 89: ...led properly Seal liquid foods with wrap Put in foods after they have cooled down Don t open the door too often and close it firmly Condensation forms in the Exterior Case Check if the ambient temperature and humidity of the surrounding air are high Is there a gap in the door gasket Wipe moisture with a dry cloth It will disappear in low temperature and humidity Fill up the gap There is abnormal n...

Страница 90: ...ing of the Refrigerant MOISTURE CLOG Cooling operation stops periodically Flowing sound of refrigerant is not heard and frost melts Lower than ambient temperature Cooling operation restarts when heating the inlet of the capillary tube CLOGGED BY DUST COMP RESSION Freezer and Refrigerator don t cool Low flowing sound of refrigerant is heard and frost forms in inlet only A little higher than ambient...

Страница 91: ...Test Very Slow None Equalization Test Very Fast Fast Very Fast Inefficient Compressor Partial Restriction Complete Restriction Condenser Temperature Cap Tube Sound Yes No Air Low Side Leak Loss of Change Very Slow Faint Hotter than Normal None to Weak Room Temperature Compressor Not Pumping Trace of Oil Undercharge The equalization test is trying to restart a compressor using a start kit after it ...

Страница 92: ...N Supply water to the ice tray by operating the solenoid valve To force water to supply to the ice tray or check icemaker s condition press and hold the FILL Key for about 3seconds In the test mode The icemaker will run through 3 stages step by step Harvest Fill water Ice making To reset the icemaker s operation set the power switch OFF position and back it to ON position Icemaker Unit Power Switc...

Страница 93: ...e passed to make one series of ices after water comes into icemaker Test Mode should not be carried out before checking below 13 2 3 Fill Park Position Once the normal harvest mode has been completed the water solenoid will be activated Not making ice Water Yes Yes No No No Temperature Time Is Icemaker s tray filled with water or Ice Is measured temperature below 10 F in the icemaker compartment H...

Страница 94: ...agnosed Follow the procedure step by step to check to see if icemaker and Ice detecting sensor is working normally 1st STEP Icemaker Unit Diagnosis Press the fill key for about 3sec If the icemaker runs 2 stages of harvest and filling water step by step It means icemaker s mechanism is normal Caution Be sure that the ice tray is not filled with water before pressing fill key Icemaker Unit Fill Key...

Страница 95: ...arm air could get into the compartment and make ices get stuck Replace the cap duct with new one In door geared motor doesn t work Resolution Change the in door geared motor and test it The water comes out of fill cup and the water get into the ice bin Resolution The water pressure from shutoff valve is too high Recommend to use regulator to the customer and close the shutoff valve slightly Clogge...

Страница 96: ... setting is F and the display temperature mode can be changed from F to C or C to F by pressing and holding the FRZ TEMP and the REF TEMP keys at the same time for over 5 seconds 14 1 3 Lock function dispenser and display button lock 1 When the refrigerator is first turned on the buttons are not locked LOCK is deactivated with no light on 2 To lock the display the dispenser and the control panel p...

Страница 97: ...ion press Ice plus Energy saving Button for more than 3 seconds 6 We recommend using energy saving function when you go out for quite a long time and are out of the rainy season 14 1 6 Dispenser use selection You can select water or ice by separated pad switch When you press ice type button ice type will be changed Crush or Cube Hold your cup in the dispenser for a few seconds after dispensing ice...

Страница 98: ...ear the filter installed on the multi duct is turned on when the R door is opened and off when closed 14 1 8 AUTO Mode 1 Fan installed on the multi duct on the rear side of the filter operates 2 Fan is repeatedly turned on for 10 minutes and then off for 5 minutes for 4 hours and then automatically switches over to AUTO Mode 3 If the R door is opened while the fan is operating the fan will be turn...

Страница 99: ...after the balance of the delay time 6 For the rest of the 23 hours the Ice room will be controlled at the lowest temperature 14 1 14 How to set the display mode and cancel it 1 With the refrigerator door open keep pressing the Refrigerator Temp Button and ICE PLUS Button more than 5 seconds then it goes to the display mode with Special Beep Sound With Special Beep Sound 2 Perform the same way agai...

Страница 100: ...lly start upon the selected Auto Pantry temperature control 2 You can adjust the Pantry control with three different temperature ranges by pressing the Temp Selector button 14 1 16 Defect Diagnosis Function 1 Automatic diagnosis makes servicing the refrigerator easy 2 When a defect occurs the buttons will not operate but the tones such as ding will sound 3 When the defect CODE removes the sign it ...

Страница 101: ...A 405H 332C 405C 405F 407A 315B 106A 106A 249C 249D 317A 318A 312C 404A 146G 315B 315C B01 105A 271D 406D B01 207A 329A 313A 411A 500A S10 610E 262B 262H 302B 406B CASE PARTS CAUTION Use the part number to order part not the position nu mber 250F 400A 316A 316B 402A 402A 610F 610D 626A 624G 624C 145B 120B 150D 120A 158B 158D 319A 308C S20 ...

Страница 102: ...133B 131A 133B 145F 133B 136A 133A 132P 145C 136C 237C FREEZER PARTS CAUTION Use the part number to order part not the position nu mber ...

Страница 103: ...REFRIGERATOR PARTS CAUTION Use the part number to order part not the position nu mber 141A 141A 139A 140A 162A 145D 162B 151A 151B 161C 141D 146C 146B ...

Страница 104: ...3A 233C 241M 279M 212G 231A 244F 406E B06 B02 242M 250W 312F 207D 281H 281H 232A 281B 631A 241B 241B 241A 241E 233A 241J 402A 231C S14 243L 243K 271E 276D 406H 406J S14 406I 203A 206L 206K 212D B06 B06 201A 243B 243C 619B 262C 241K 241K 241K 241G 312B 231B 233B 235A 244A 409B 158C 309G 310G 231C 279E 500C 102A 406F 243K ...

Страница 105: ...DISPENSER PARTS CAUTION Use the part number to order part not the position nu mber 279H 279J 402C 406A 275A 279A 104A 612C 612B ...

Страница 106: ...VALVE WATER TUBE PARTS r e b m u n n o i t i s o p e h t t o n t r a p r e d r o o t r e b m u n t r a p e h t e s U N O I T U A C 617A 623B 625A 616J 627B 616E 623A 619A 627A 625A 603C 616J 616H ...

Страница 107: ...ICE MAKER ICE BIN PARTS CAUTION Use the part number to order part not the position number 630F 630B 630H 630G 630C 630Q 630E 630D 611A 630J 630J 630F 600C 600A Freezer Room 600B 600F 612A ...

Страница 108: ...Jun 2017 Printed in China ...

Отзывы: