The air conditioner is designed to be installed in a double- or single-hung
window with an actual opening width of 25 ~ 36 inches (not through a hole
in a wall or other structural modification) and plugged into a single-outlet,
dedicated 15-amp circuit without using an extension cord.
All applicable clearances
should be maintained.
All side louvers on the
cabinet must remain exposed
on the outside of the structure.
p9
LWHD1006R
Installation
Содержание LWHD1006R
Страница 1: ...COMBO TRAINING LWHD1006R Air Conditioner LWHD1006R ...
Страница 14: ...p10 LWHD1006R Dimensions ...
Страница 18: ...Attach the adhesive foam strip 11 to the bottom of the upper guide 10 p12 LWHD1006R Installation ...
Страница 30: ...Open the front panel and attach the grille to the chassis using a Type A screw p14 LWHD1006R Installation ...
Страница 34: ...When Needed Both Main Display Boards should be replaced Part 4994A10029A Complete Wiring ...
Страница 35: ...When Replacing Display Main Boards Carefully Remove Insert Ribbon Complete Wiring Part 4994A10029A LWHD1006R ...
Страница 36: ...Run Capacitor 50 Hermetric 6 Fan 5 MFD 270 Volts ...
Страница 38: ...2650 x Amps Volts MFD 2650 X 3 194 41 MFD LWHD1006R Checking a Run Capacitor ...
Страница 39: ...2650 X Amps Volts MFD 2650 X 2 32 122 4 50 2 Run Capacitor NOT in Circuit Hermetric 50mfd LWHD1006R ...
Страница 40: ...2650 X 2 29 122 6 49 5 Capacitor NOT in Circuit 50mfd LWHD1006R ...
Страница 41: ...FAN 6 mfd 2650 x 0 26 122 9 5 6 Capacitor NOT in Circuit LWHD1006R ...
Страница 42: ...Tubes are inserted approx 1 2 LWHD1006R ...
Страница 43: ...When Replacing an EVAP All 8 Lines must be Removed 1 2 3 4 1 2 3 4 LWHD1006R ...
Страница 44: ...Condenser Inlet Tubes ...
Страница 45: ...OPERATIVE Green Indicator is lit ...
Страница 46: ...Operative Green Indicator is Lit ...
Страница 47: ...Inoperative Display is NOT Lit ...
Страница 67: ...SERVICE EQUIPMENT setup and connection p25 Pulling Vacuum Charging LWHD1006R Refrigeration Cycle ...
Страница 68: ...p26 LWHD1006R Schematic ...
Страница 69: ...p27 LWHD1006R Wiring Diagram ...
Страница 70: ...p28 LWHD1006R Parts Location ...
Страница 71: ...COMPONENT LOCATION p28 LWHD1006R Main Board ...
Страница 72: ...COMPONENT LOCATION p28 LWHD1006R Display Board ...
Страница 73: ...p29 LWHD1006R Piping System ...
Страница 74: ...p29 LWHD1006R Sealed Cycle ...
Страница 75: ...p30 NO COOLING LWHD1006R Troubleshooting ...
Страница 76: ...NO START p31 LWHD1006R Troubleshooting ...
Страница 77: ...DOESN T RUN p32 LWHD1006R Troubleshooting ...
Страница 78: ...COMPRESSOR DOES NOT RUN p33 LWHD1006R Troubleshooting ...
Страница 79: ...COMPRESSOR RUNS ALL THE TIME p33 LWHD1006R Troubleshooting ...
Страница 80: ...FAN RUNS ALL THE TIME or NOT AT ALL p34 LWHD1006R Troubleshooting ...
Страница 81: ...ENERGY SAVER DOES NOT OPERATE p34 LWHD1006R Troubleshooting ...
Страница 83: ...ABNORMAL DISPLAY p35 LWHD1006R Troubleshooting ...
Страница 84: ...p36 LWHD1006R Troubleshooting ...
Страница 85: ...p36 LWHD1006R Troubleshooting ...
Страница 86: ...p36 LWHD1006R Troubleshooting ...
Страница 87: ...p37 LWHD1006R Troubleshooting ...
Страница 88: ...p37 LWHD1006R Troubleshooting ...
Страница 89: ...p37 LWHD1006R Troubleshooting ...
Страница 90: ...p38 LWHD1006R Exploded View ...