Air

conditioner

does not 

start

The air conditioner is 

unplugged.

Make sure the air conditioner plug is pushed 

completely into the outlet.

The fuse is blown/circuit 

breaker is tripped.

Check the house fuse/circuit breaker box and 

replace the fuse or reset the breaker.

Power failure.

If power failure occurs, turn the mode control

to Off. When power is restored, wait 3 minutes

to restart the air conditioner to prevent tripping 

of the compressor overload.

The current interrupter 

device is tripped.

Press the RESET button located on the power

cord plug. If the RESET button will not stay 

engaged, discontinue use of the air conditioner 

and contact a qualified service technician.

Air conditioner

does not cool

as it should

Air conditioner

freezing up

Water drips 

outside

Water drips 

indoors

Water collects 

in base pan

Airflow is restricted.

The room may have been 

hot.

Cold air is escaping.

Cooling coil have iced up.

The cooling coils are iced

over.

Hot, humid weather.

The air conditioner is not 

tilted to the outside.

Moisture removed from air 

and drains into base pan.

The air filter is dirty.

Make sure there are no curtains, blinds, or 

furniture blocking the front of the air conditioner.

In

COOL

 model

press the 

DECREASE

   pad.

Clean the filter at least every 2 weeks.

See the care and Maintenance section.

When the air conditioner is first turned on, you 

need to allow time for the room to cool down.
Check for open furnace floor registers and cold 

air returns.

See Air Conditioner Freezing Up below.
Ice may block the air flow and obstruct the air

conditioner from properly cooling the room. 

Set the mode control at High Fan or High Cool.
This is normal.
For proper water disposal, make sure the air 

conditioner slants slightly from the case front 

to the rear.

This is normal for a short period in areas with 

little humidity; normal for a longer period in 

very humid areas.

The temp control may not

be set correctly.

Air conditioner 

turns on and 

off rapidly.

Dirty air filter - air restricted. Clean air filter.

Noise when 

unit is cooling.

Air movement sound.

This is normal. If too loud, set to lower FAN setting.

Window vibration - poor 

installation.

Refer to installation instructions or check with 

installer.

Remote

Sensing

Deactivating

Prematurely.

Remote control not located 

within range.

Place remote control within 20 feet & 120° radius 

of the front of the unit

Remote control signal 

obstructed.

Remove obstruction.

Room too 

cold.

Set temperature too low

lncrease set temperature.

Set FAN speed to a faster setting to bring air 

through cooling coils more frequently.

Outside temperature 

extremely hot.

If you see “CH” in the display, please call 1-800-243-0000.

22

Содержание LW7014HR

Страница 1: ...OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your air conditioner and retain it for future reference P NO MFL68061601 www lgappliances com TYPE WINDOW MODEL LW7014HR ...

Страница 2: ...7 16 20 Safety Precautions Operating Instructions Before Operation Introduction Electrical Safety Installation Maintenance and Service ...

Страница 3: ...Do not store flammables like gasoline benzene thinner etc near the air conditioner ...

Страница 4: ...No correlation between fan usage and oxygen depletion Unplug the unit when not using it for a long time ...

Страница 5: ...e when taking Never touch the metal parts of the unit when removing the filter Install the product so the exhaust and noise are not aimed directly at the neighbors For inner cleaning contact an Authorized Service Center or a dealer Do not use harsh detergent that causes corrosion or damage on the unit Harsh detergent may also cause failure of product fire or electric shock ...

Страница 6: ...ecial purposes such as cooling pets foods precision machinery or objects of art If the liquid from the battery gets onto your skin or clothers wash it well with clean water Do not use the remote if the battery has leaked y y If you eat the liquid from the battery brush your teeth and see doctor Do not use the remote if the battery has leaked ...

Страница 7: ...2 No correlation between fan usage and oxygen depletion 3 ...

Страница 8: ...otes NOTICE This appliance should be installed in accordance with the National Electric Code Introduction Symbols Used in this Manual Features Evaporator Electric Heater Control Board Brace Vertical Air Deflector Horizontal Louver Horizontal Air Deflector Vertical Louver Air Discharge Cabinet Front Grille Air Filter Air Intake Inlet Grille Condenser Base Pan Compressor Power Cord Remote Controller...

Страница 9: ...should be Avoid shock hazard This unit cannot be user serviced Do NOT open the tamper resistant sealed portion All warranties and performance will be voided This unit is not intended to be used as an ON OFF switch ...

Страница 10: ......

Страница 11: ...le Wrench Left Guide Panel Right Guide Panel Curtain 13 EA 2 EA 3 EA 5 EA 2 EA 2 EA 2 EA 1EA 2 EA 1 EA 1 EA 1 EA Not adhesive backed Adhesive backed Phillips head screwdriver Scissors or knife Owner s Manual 11 ...

Страница 12: ...ssis 1 To prevent vibration and noise make sure the unit is installed securely and firmly 2 Install the unit where the sunlight does not shine directly on the unit 3 The outside of the cabinet must extend outward for at least 11 and there should be no obstacles such as a fence or wall within 20 from the back of the cabinet because it will prevent heat radiation of the condenser Restriction of outs...

Страница 13: ...13 hole Center hole the base pan Adhesive backed adhesive backed upper guide sill support frame curtain 8 Right Guide Panel Upper guide Type A Screws Frame guide Left Guide panel ...

Страница 14: ...14 Screw Screw removed from the cabinet at See page 12 frame guides sill support sill support frame curtain frame curtain ...

Страница 15: ...you push it in 15 16 A screw through the front grille Before installing the front grille pull out the vent control lever located above the unit control knobs as shown Lift the inlet grille and secure it with a Type not adhesive backed 15 Not adhesive backed Type C ...

Страница 16: ...s not run Use the FAN button to set Heat Heater runs and heats the room when the air conditioner is off it can be set to automatically turn Delay OFF when the air conditioner is on it can be set to automatically turn on from 1 to 24 hours at its previous mode and fan settings off from 1 to 24 hours Delay ON ON OFF TIMER FAN SPEED SELECTOR Use to set the fan speed to Low F1 High F2 Power Temp Fan S...

Страница 17: ...humb 2 Pay attention to polarity and insert one new AAA 1 5V battery 3 Reattach the cover Operating Instructions FILTER RESET Clean Filter LED will light up to notify you that your filter needs to be cleaned After cleaning the filter press Filter Reset button to turn off Clean Filter light During operation in failure of electric power the unit runs as previous setting operation The unit defaults t...

Страница 18: ... flow direction NOTICE When the unit operates in extremely hot weather it turns off automatically to protect compressor The horizontal direction is adjusted by moving the lever to the left or right Touch the horizontal louvers to adjust the air airflow up or down ...

Страница 19: ...19 drain base pan base pan Slinger Fan ...

Страница 20: ...nlet grille upward 2 Remove the air filter from the front grille by pulling the air filter up slightly 3 Wash the filter using lukewarm water below 40 4 Gently shake the excess water from the filter and replace 20 ...

Страница 21: ...may vibrate and make noise because of poor wall or window construction or incorrect installation Vibration Today s high efficiency compressors may have a high pitched chatter during the cooling cycle High pitched Chatter Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Gurgle Hiss operation may cause call 1 800 243 0000 an outlet of the p...

Страница 22: ...d Clean the filter at least every 2 weeks See the care and Maintenance section When the air conditioner is first turned on you need to allow time for the room to cool down Check for open furnace floor registers and cold air returns See Air Conditioner Freezing Up below Ice may block the air flow and obstruct the air conditioner from properly cooling the room Set the mode control at High Fan or Hig...

Страница 23: ...ápida de problemas encontrará muchas respuestas a los problemas más habituales Si revisa primero nuestra Tabla de Consejos para la solución rápida de problemas tal vez no necesite llamar nunca al servicio técnico PRECAUCIÓN Póngase en contacto con un técnico del servicio autorizado para realizar la reparación y mantenimiento de esta unidad Póngase en contacto con un instalador para realizar la ins...

Страница 24: ...24 Aire Acondicionador ...

Страница 25: ...Manual del Propietario 25 ...

Страница 26: ...ice detergentes abrasivos que causan corrosión o dañan la unidad Los detergentes abrasivos pueden igualmente provocar un fallo del producto un incendio o una descarga electrónica No opere ni detenga la unidad insertando o estirando de enchufe No dane ni use un enchufe de alimentaci on no especificado No toque el producto con las manos mojadas o en un ambiente h umedo 26 ...

Страница 27: ... No utilice el control remoto si las pilas tienen fugas l Si el l quido de las pilas alcanzara su boca cepille sus dientes y consulte a un medico No utilice el mando a distancia si las pilas han experimentado fugas Manual del Propietario 27 Contiene elementos de contención y hacer que se enferme ...

Страница 28: ...23 El funcionamiento del ventilador no afectará a la reducción de oxígeno ...

Страница 29: ...Características aparencia puede variar Este aparato debería instalarse de acuerdo con las normas del Código Eléctrico Nacional Evaporador Panel de control Abrazadera Deflector de aire vertical Rejilla horizontal Deflector de aire horizontal Rejilla vertical Descarga de aire Gabinete Rejilla frontal Filtro de aire Control remoto Condensador Plator de base Compresor Cable de alimentacion Entrada de ...

Страница 30: ...tos de nacimiento y otros daños al sistema reproductor Lávese bien las manos tras manipular el dispositivo No desmonte modifique ni sumerja en agua este enchufe Si el dispositivo se activara deberá corregir Los hilos conductores dentro del cable están rodeados por blindajes que supervisan la corriente de fuga Examine periódicamente el cable en busca de cualquier daño No utilice este producto si lo...

Страница 31: ...a Adaptar la terminal del ground del adaptador a la cubierta de la pared con un tornillo no neutraliza el aparato a menos que la cubierta del tornillo sea de metal u no sea insolada y el receptor de pared este neutralizado a través del alambrado del la casa El cliente debe hacer verificar el circuito por un electricista calificado para asegurarse que el receptor esta debidamente neutralizado Desco...

Страница 32: ...aldado TORNILLO TIPO A TORNILLO TIPO B TORNILLO TIPO C DINTEL DE SOPORTE PERNO TUERCA MARCO DE LA CORTINA BURLETE DE ESPUMA CANO DE DRENAJE GUIA DEL MARCO ABRAZADERA DE FIJACIONA LA VENTANA BURLETE DE ESPUMA PE Grupo Guía de la izquierda Grupo Guía de derecho Cortina Lapiz Un destornillador de estrella Tijeras o cuchilla 32 Aire Acondicionador ...

Страница 33: ...dad un poco inclinada de tal forma que la parte trasera esté ligeramente más baja que el frente cerca de 1 2 Esto forzará el agua del condensador hacia afuera 5 Instale la unidad con la parte inferior cerca de 30 60 arriba nivel de suelo Esta unidad está diseñada para que sea instalada en ventanas dobles estándares con una abertura actual de ancho desde 22 a 36 La parte superior e inferiro de la v...

Страница 34: ...Instalacion Adhesivo respaldado Burlete de espuma pe Adhesivo respaldado 8 34 Aire Acondicionador Guia del marco Grupo Guía de derecho Guia superior Tipo A Tornillos Grupo Guía de la izquierda ...

Страница 35: ...35 Tipo C Tipo C Tipo C Tipo C Tornillo Tornillo ...

Страница 36: ...la parrilla frontal Antes de instalar la parrilla frontal tire hacia afuera de la control de ventilacion localizada encima de los botones de control de la unidad como se muestra No adhesivo respaldado No adhesivo respaldado 14 Guie la palanca cuidadosamente a traves de la parrilla mientras la empuja NOTA 15 16 ...

Страница 37: ...entilador para configurar la velocidad deseada del ventilador HEAT Calentar El calentar funciona y calentar la habitación CRONOMETRO ON OFF Encendido Cuando el acondicionador de aire esta apagado puede ajustarse para que se encienda automaticamente dentro de 1 a 24 horas en el nivel previo Apagado Cuando el acondicionador de aire esta apagado puede ajustarse para que se apague automaticamente dent...

Страница 38: ...ad es un recordatorio para limpiar el Filtro de Aire Consulte Mantenimiento para un funcionamiento más eficiente La luz LED se iluminará después de 250 horas de funcionamiento 7 Insertar las batería del control remoto 1 Empuje hacia afuera con su pulgar la cubierta en la parte posterior del control remoto 2 Preste atención a la polaridad e inserte dos nuevas batería AAA 1 5V 3 Vuelva a colocar la ...

Страница 39: ...poco del aire interno es expelido hacia afuera Direccion del aire El flujo de aire puede ser ajustado cambiando la direccion de las rejillas de ventilacion del acondicionador deaire La direccion horizontal del aire es ajustada moviendo la palanca hacia la derecha o izquierda Una presion sencilla con los dedos en las parrillas ventical ajustara la direccion del aire CONSEJO Manual del Propietario 3...

Страница 40: ...40 Aire Acondicionador Ventilador de extracción ...

Страница 41: ...Manual del Propietario 41 ...

Страница 42: ...orboteo Siseo Un sonido parecido a un borboteo o siseo puede escucharse debido al refrigerante pasando a través del evaporador durante una normal operación Vibración La unidad puede vibrar y hacer ruido debido a una estructura débil de la pared o la ventana o a una instalación incorrecta Goteo o chapoteo Las gotas de agua que caen sobre el condensador durante la normal operación del producto puede...

Страница 43: ...eratura mas alta El aire acondiciona do enfria dernasiado El hielo bloquea el flujo de aire y detiene el enfriamiento del cuarto Elija el modo alto del ventilador High Fan o enfriado alto High Cool Clima caliente y humedo Esto es normal Hay goteo de aguaen la parte El acondicionador de aire no esta inclinado hacia el exterior Para una salida correcta del agua asegurese de que el acondicionador de ...

Страница 44: ...44 ...

Страница 45: ...45 ...

Страница 46: ...accidents pests and vermin lightning wind fire floods or acts of God 5 Damage or failure resulting from misuse abuse improper installation repair or maintenance Improper repair includes use of parts not approved or specified by LG 6 Damage or failure caused by unauthorized modification or alteration to the product 7 Damage or failure caused by incorrect electrical current voltage or plumbing codes...

Страница 47: ...nsuficiente de agua o interrumpido o suministro insuficiente de aire 4 Los daños o averías causados por accidentes plagas e insectos rayos viento fuego inundaciones o actos de Dios 5 Los daños o fallos ocasionados por el mal uso abuso instalación inadecuada reparación o mantenimiento Se considera reparación inadecuada aquella en que se hayan utilizado piezas no aprobadas o especificadas por LG 6 L...

Страница 48: ...1 800 243 0000 LG Customer Information Center Register your product Online www lgappliances com LG ELECTRONICS INC 1000 Sylvan Ave Englewood Cliffs NJ 07632 ...

Отзывы: