ENGLISH
11
INSTALLATION
Window Requirements
●
This unit is designed for installation in standard
double hung windows with actual opening
widths from 21" to 35".
The top and bottom window sashes must open
12" from the bottom of the upper sash to the
inside sill.
21" to 35"
(533mm to 889mm)
12"
(305mm)
min
NOTE
●
This prodcut is a WINDOW AIR CONDITIONER.
As such, a standard single-hung or double-hung
window is required for proper installation.
No-window installations, including using sleeves,
holes in walls, and other installations are not
recommended.
Preparation of Chassis
1
1
The bottom of the cabinet should be
30” ~ 60” above the ground.
2
The outside of cabinet must extend outward
for at least 1/2”.
3
There should be no obstacles such as a
fence or wall within 20” from the back of the
cabinet.
4
All side louvers of the cabinet must remain
exposed to the outside of the structure.
Clearance
Proper clearance enhances the cooling efficiency
of the unit and prevents heat radiation of the
condenser.
Location
Install the air conditioner where the sunlight does
not shine directly on the unit.
Insert the guide panels into the guides of
the air conditioner. Fasten the curtains to
the unit with screws (Type A).
(Without Frame Curtain)
Offset
Sill
Exterior
Stool
Interior Wall
Fence
Awning
Cooled Air
Heat
About
Over
Radiation
Type A
Type A
Type A
(533mm to 889mm)
21″ to 35″
(305mm)
12″
min
17 2/7″(439mm) min
1/2″ (12.7mm)
1/2″ to 1 1/4″
( )
20″ (508mm)
(762mm~1524mm)
30″ ~60″
2
Cut the adhesive-backed seal strip to the
window width. Remove the backing from
the seal strip and attach the seal strip to
the underside of the bottom window.
Seal Strip