background image

Air

conditioner

does not 

start

The air conditioner is 

unplugged.

Make sure the air conditioner plug is pushed 

completely into the outlet.

The fuse is blown/circuit 

breaker is tripped.

Check the house fuse/circuit breaker box and 

replace the fuse or reset the breaker.

Power failure.

If power failure occurs, turn the mode control

to Off. When power is restored, wait 3 minutes

to restart the air conditioner to prevent tripping 

of the compressor overload.

The current interrupter 

device is tripped.

Press the RESET button located on the power

cord plug. If the RESET button will not stay 

engaged, discontinue use of the air conditioner 

and contact a qualified service technician.

Air conditioner

does not cool

as it should

Air conditioner

freezing up

Water drips 

outside

Water drips 

indoors

Water collects 

in base pan

Airflow is restricted.

The room may have been 

hot.

Cold air is escaping.

Cooling coil have iced up.

The cooling coils are iced

over.

Hot, humid weather.

The air conditioner is not 

tilted to the outside.

Moisture removed from air 

and drains into base pan.

The air filter is dirty.

Make sure there are no curtains, blinds, or 

furniture blocking the front of the air conditioner.

In

COOL

 model

press the 

DECREASE

   pad.

Clean the filter at least every 2 weeks.

See the care and Maintenance section.

When the air conditioner is first turned on, you 

need to allow time for the room to cool down.
Check for open furnace floor registers and cold 

air returns.

See Air Conditioner Freezing Up below.
Ice may block the air flow and obstruct the air

conditioner from properly cooling the room. 

Set the mode control at High Fan or High Cool.
This is normal.
For proper water disposal, make sure the air 

conditioner slants slightly from the case front 

to the rear.

This is normal for a short period in areas with 

little humidity; normal for a longer period in 

very humid areas.

The temp control may not

be set correctly.

Air conditioner 

turns on and 

off rapidly.

Dirty air filter - air restricted. Clean air filter.

Noise when 

unit is cooling.

Air movement sound.

This is normal. If too loud, set to lower FAN setting.

Window vibration - poor 

installation.

Refer to installation instructions or check with 

installer.

Remote

Sensing

Deactivating

Prematurely.

Remote control not located 

within range.

Place remote control within 20 feet & 120° radius 

of the front of the unit

Remote control signal 

obstructed.

Remove obstruction.

Room too 

cold.

Set temperature too low

lncrease set temperature.

Set FAN speed to a faster setting to bring air 

through cooling coils more frequently.

Outside temperature 

extremely hot.

You can refer to the Energy Star program in detail at www.energystar.gov.

If you see “CH” in the display, please call 1-800-243-0000.

22

Содержание LW1814ER

Страница 1: ...TYPE WINDOW MODEL LW1814ER OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your air conditioner and retain it for future reference P NO MFL68007103 www lgappliances com ...

Страница 2: ...7 16 20 Safety Precautions Maintenance and Service Before Operation Introduction Electrical Safety Installation Operating Instructions ...

Страница 3: ...Do not store flammables like gasoline benzene thinner etc near the air conditioner ...

Страница 4: ...No correlation between fan usage and oxygen depletion Unplug the unit when not using it for a long time ...

Страница 5: ...e when taking Never touch the metal parts of the unit when removing the filter Install the product so the exhaust and noise are not aimed directly at the neighbors For inner cleaning contact an Authorized Service Center or a dealer Do not use harsh detergent that causes corrosion or damage on the unit Harsh detergent may also cause failure of product fire or electric shock ...

Страница 6: ...ecial purposes such as cooling pets foods precision machinery or objects of art If the liquid from the battery gets onto your skin or clothers wash it well with clean water Do not use the remote if the battery has leaked y y If you eat the liquid from the battery brush your teeth and see doctor Do not use the remote if the battery has leaked ...

Страница 7: ...2 No correlation between fan usage and oxygen depletion 3 ...

Страница 8: ......

Страница 9: ... should be Avoid shock hazard This unit cannot be user serviced Do NOT open the tamper resistant sealed portion All warranties and performance will be voided This unit is not intended to be used as an ON OFF switch ...

Страница 10: ......

Страница 11: ...e D 2 Type A 12 Carriage Bolt 2 Lock Nut 4 Type B 7 Foam strip Plain Back Right frame curtain Window locking bracket Left frame curtain Frame guide 2 Sill bracket 2 Support bracket 2 Drain joint pipe Phillips head screwdriver Scissors or knife Flat blade screwdriver 11 ...

Страница 12: ...ndow sashes must open sufficiently to allow a clear vertical opening of 18 from the bottom of the upper sash to the window stool 2 The stool offset height between the stool and sill must be less than 1 1 4 NOTICE 29 41 18 Keep the screws for Iater use Remove 4 screws which fasten the cabinet at both sides and at the back pan adhesive backed 1 2 3 4 frame guides Adhesive backed Preparation Of Chass...

Страница 13: ...he lock nut attach the support bracket to the cabinet track hole Use the first track hole after the sill bracket on the outer edge of the window sill Tighten the carriage bolt and the lock nut Be sure the cabinet slants outward Cabinet Track hole Support Bracket Carriage bolt and lock nut Machine screw Type D and lock nut Outer edge of window sill Front angle Window stool Top retainer bar Do not d...

Страница 14: ... each frame curtain fully to each window sash track and pull the bottom window sash down behind the top retainer bar until it meets 3 Attach each frame curtain the window sash by using screws Type C 4 5 Slide the unit into the cabinet For security purpose reinstall screws removed from cabinet at cabinet s sides See page 12 Window locking bracket 6 7 Cut the foam strip Not adhesive backed window sa...

Страница 15: ...abs the grille into the slots on the front the cabinet Push the grille in until it snaps into place and secure it with 2 Type A screws through Before installing the front grille pull out the vent control lever located above the unit control knobs as shown Put down inlet grille and take out the filter the front grille 8 9 10 ...

Страница 16: ...the desired temperature and circulation fan speed Energy Saver The fan stops when the compressor stops cooling Approximately every 3 minutes the fan will turn on and check the room air temperature if cooling is needed Fan Fan circulates air but compressor does not run Use the FAN button to set Operation starts when this button is pressed and stops when you press the button again FAN SPEED SELECTOR...

Страница 17: ...it runs as previous setting operation Do not use rechargeable battery Make sure that the battery is new Do not mix alkaline standard Carbon zinc or rechargeable Nickel cadmium battery In order to prevent discharge remove the battery from the remote control if the air conditioner is not going to be used for an extended period of time To maintain optimal operation of the remote control the remote se...

Страница 18: ... flow direction The horizontal direction is adjusted by moving the lever to the left or right Touch the horizontal louvers to adjust the air airflow up or down NOTICE When the unit operates in extremely hot weather it turns off automatically to protect compressor ...

Страница 19: ...19 drain base pan base pan Slinger Fan ...

Страница 20: ...emove the air filter from the front grille by pulling forward the air filter and 2 Wash the filter using lukewarm water below 40 3 Gently shake the excess water from the filter and replace then up slightly ...

Страница 21: ...t of the unit you may hear the sound of rushing air being moved by the fan Sound of Rushing Air Unit may vibrate and make noise because of poor wall or window construction or incorrect installation Vibration Today s high efficiency compressors may have a high pitched chatter during the cooling cycle High pitched Chatter Gurgling or hissing noise may be heard due to refrigerant passing through evap...

Страница 22: ...weeks See the care and Maintenance section When the air conditioner is first turned on you need to allow time for the room to cool down Check for open furnace floor registers and cold air returns See Air Conditioner Freezing Up below Ice may block the air flow and obstruct the air conditioner from properly cooling the room Set the mode control at High Fan or High Cool This is normal For proper wat...

Страница 23: ...ones de Seguridad 24 Antes de poner el equipo en funcionamiento 28 Introduccion 29 Seguridad Electrica 30 Instalacion 32 Instrucciones de Funcionamiento 37 Mantenimiento y Servicio 41 Manual del Propietario 23 ...

Страница 24: ...24 ...

Страница 25: ...Manual del Propietario 25 ...

Страница 26: ...ice detergentes abrasivos que causan corrosión o dañan la unidad Los detergentes abrasivos pueden igualmente provocar un fallo del producto un incendio o una descarga electrónica No opere ni detenga la unidad insertando o estirando de enchufe No dane ni use un enchufe de alimentaci on no especificado No toque el producto con las manos mojadas o en un ambiente h umedo 26 ...

Страница 27: ...vela inmediatamente con agua No utilice el control remoto si las pilas tienen fugas l Si el l quido de las pilas alcanzara su boca cepille sus dientes y consulte a un medico No utilice el mando a distancia si las pilas han experimentado fugas Manual del Propietario 27 ...

Страница 28: ...23 El funcionamiento del ventilador no afectará a la reducción de oxígeno ...

Страница 29: ...29 ...

Страница 30: ...tos de nacimiento y otros daños al sistema reproductor Lávese bien las manos tras manipular el dispositivo No desmonte modifique ni sumerja en agua este enchufe Si el dispositivo se activara deberá corregir Los hilos conductores dentro del cable están rodeados por blindajes que supervisan la corriente de fuga Examine periódicamente el cable en busca de cualquier daño No utilice este producto si lo...

Страница 31: ...a asegurarse una polarización adecuada Adaptar la terminal del ground del adaptador a la cubierta de la pared con un tornillo no neutraliza el aparato a menos que la cubierta del tornillo sea de metal u no sea insolada y el receptor de pared este neutralizado a través del alambrado del la casa El cliente debe hacer verificar el circuito por un electricista calificado para asegurarse que el recepto...

Страница 32: ...ipo B 7 Tira de goma Soporte de cerradura Panel Guia 2 Mensula del alfeizar 2 Mensula de soporte 2 Tapa del desague Un destornillador de estrella Tijeras o cuchilla Un destornillador con hoja plana Panel Guia Guia Marco Seguridad 4 Lapiz Una regla o cinta metrica Nivel 32 Aire Acondicionador ...

Страница 33: ... 3 4 Mantener los tornillos para su uso posterior Quite los tornillos que unen el gabinete a ambos lados y a la parte posterior Adhesivo respaldado de fijacion Burlete de espuma pe Adhesivo respaldado Tornillos Manual del Propietario 33 ...

Страница 34: ...1 5 6 Mensula Del Alfeizar Bulon Mensula De Soporte Tuerca de Segurida Guia del marco Grupo Guía de derecho Guia superior Tipo A Tornillos Grupo Guía de la izquierda 10 2 3 4 34 Aire Acondicionador ...

Страница 35: ...Tipo C Tipo C Tipo C Tipo C 3 4 5 6 7 Adhesivo respaldado Adhesivo respaldado 35 ...

Страница 36: ... con 2 Tipo Unos tornillos a través de la rejilla frontal tire hacia afuera de la control de ventilacion localizada encima de los botones de control de la unidad como se muestra Guie la palanca cuidadosamente a traves de la parrilla mientras la empuja NOTA 36 Aire Acondicionador ...

Страница 37: ...o de 1 a 24 horas El ventilador se detiene cuando el compressor no Aporximadamente cada 3minutos el ventilador se encendera y sigue enfriando necesitara verificar la temperatura del cuarto para saber si es necesario mas enfriamiento y FAN ventilador para configurar la temperatura deseada y la velocidad de FAN ventilador El ventilador hace circular el aire pero el compresor no funciona circulación ...

Страница 38: ...JO Esta funcionalidad es un recordatorio para limpiar el Filtro de Aire Consulte Mantenimiento para un funcionamiento más eficiente La luz LED se iluminará después de 250 horas de funcionamiento La unidad pasa de forma predeterminada al modo de Ahorro de Energía cada vez que la unidad se enciende excepto al restaurarse después de una falla de la energía eléctrica AHORRADOR DE ENEERGIA Insertar las...

Страница 39: ...cia afuera OUVRIR FERMER AERER Direccion del aire El flujo de aire puede ser ajustado cambiando la direccion de las rejillas de ventilacion del acondicionador deaire La direccion horizontal del aire es ajustada moviendo la palanca hacia la derecha o izquierda Una presion sencilla con los dedos en las parrillas ventical ajustara la direccion del aire CONSEJO UANDO LA UNIDAD OPERA EN CLIMA EXTREMADA...

Страница 40: ...40 Aire Acondicionador Ventilador de extracción ...

Страница 41: ...41 1 Quite el filtro de aire de la rejilla frontal tirando de él hacia delante y hacia arriba ligeramente 2 3 ...

Страница 42: ...a través del evaporador durante una normal operación Traqueteo agudo Los compresores modernos de alto rendimiento pueden presentar un traqueteo agudo durante el ciclo de enfriado Vibración La unidad puede vibrar y hacer ruido debido a una estructura débil de la pared o la ventana o a una instalación incorrecta Goteo o chapoteo Las gotas de agua que caen sobre el condensador durante la normal opera...

Страница 43: ...eratura mas alta El aire acondiciona do enfria dernasiado El hielo bloquea el flujo de aire y detiene el enfriamiento del cuarto Elija el modo alto del ventilador High Fan o enfriado alto High Cool Clima caliente y humedo Esto es normal Hay goteo de aguaen la parte El acondicionador de aire no esta inclinado hacia el exterior Para una salida correcta del agua asegurese de que el acondicionador de ...

Страница 44: ...es plagas e insectos rayos viento fuego inundaciones o actos de Dios 5 Los daños o fallos ocasionados por el mal uso abuso instalación inadecuada reparación o mantenimiento Se considera reparación inadecuada aquella en que se hayan utilizado piezas no aprobadas o especificadas por LG 6 Los daños o averías causados por modificaciones no autorizadas o alteraciones del producto 7 Los daños o averías ...

Страница 45: ...accidents pests and vermin lightning wind fire floods or acts of God 5 Damage or failure resulting from misuse abuse improper installation repair or maintenance Improper repair includes use of parts not approved or specified by LG 6 Damage or failure caused by unauthorized modification or alteration to the product 7 Damage or failure caused by incorrect electrical current voltage or plumbing codes...

Страница 46: ...1 800 243 0000 LG Customer Information Center Register your product Online www lgappliances com LG ELECTRONICS INC 1000 Sylvan Ave Englewood Cliffs NJ 07632 ...

Отзывы: