background image

6

Contents and Features

Contents

Part Names and Functions . . . . . . . . . . . . . . .7-9
Connections  . . . . . . . . . . . . . . . . . . . . . . . .10
Mounting the Lens . . . . . . . . . . . . . . . . . .11-12
Concerning Auto-Iris Lenses  . . . . . . . . . . .13-14
Function Switch Settings  . . . . . . . . . . . . . . . .15
Day&Night Function Settings  . . . . . . . . . . .16-17
Line Lock Phase Adjustment . . . . . . . . . . . . . .18
Flange-back Adjustment  . . . . . . . . . . . . . . . .19
Installation of Camera  . . . . . . . . . . . . . . . . .20
Specifications  . . . . . . . . . . . . . . . . . . . . .21-22

Features

This color video camera is designed for use in mon-
itoring system.
• High resolution and high sensitivity with a 1/3

inch Super HAD CCD (Charge Coupled Device)

• CS Mount (Adapter Ring Mount for C Lens:

Optional)

• Line Lock when using AC24V power.
• Dual power : AC 24V or DC 12V
• Non-polarity DC12V

Maintenance of the unit

• Remove dust or dirt on the surface of the lens

with a blower.

• Use a dry soft cloth to clean the body. If it is

very dirty, use a cloth dampended with a small
quantity of neutral detergent and then wipe dry.

• Avoid the use of volatile solvents such as thin-

ners, alcohol, benzene, and insecticides. They
may damage the surface of the body.

LVC-SX811HP_ENG_MFL-180  7/19/07  3:04 PM  Page 6

Содержание LVC-SX811HM

Страница 1: ...ra Instruction Manual Models LVC SX811HM LVC SX811HP Before installing operating or adjusting this product please read this instruction booklet carefully and completely LVC SX811HP_ENG_MFL 180 7 19 07 3 04 PM Page 1 ...

Страница 2: ...ed to provide reasonable protection against harmful inter ference when the equipment is operated in a commer cial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accor dance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful ...

Страница 3: ... vases should be placed on the appara tus Disposal of your old appliance 1 When this crossed out wheeled bin symbol is attached to a product it means the product is covered by the European Directive 2002 96 EC 2 All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facili ties appointed by the government or the local autho...

Страница 4: ...loth Unplug this prod uct from the wall outlet before cleaning Do not use liquid cleaners 7 Do not block any ventilation openings Install in accordance with the manufactur er s instructions Slots and openings in the cabinet are provided for ventilation to ensure reliable operation of the product and to protect it from over heating The openings should never be blocked by placing the product on a be...

Страница 5: ...ratus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod brack et or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Refer all servici...

Страница 6: ...high sensitivity with a 1 3 inch Super HAD CCD Charge Coupled Device CS Mount Adapter Ring Mount for C Lens Optional Line Lock when using AC24V power Dual power AC 24V or DC 12V Non polarity DC12V Maintenance of the unit Remove dust or dirt on the surface of the lens with a blower Use a dry soft cloth to clean the body If it is very dirty use a cloth dampended with a small quantity of neutral dete...

Страница 7: ...fixed at the top or bottom of the camera page 20 2 Lens mount cap The cap is installed to protect the lens mount section Remove the lens mount cap before installing a lens 3 Flange back lock screw 4 Flange back adjustment dial LVC SX811HP_ENG_MFL 180 7 19 07 3 04 PM Page 7 ...

Страница 8: ...ys be operated a AC 24V DC 12 V Certified Listed class 2 power sup ply only 7 D N connector for manual day setting See page 16 8 D N connector for manual night setting See page 16 9 Lens iris output connector LENS This 4 pin connector is used to send the Iris control signal and power supply to an auto iris type lens LVC SX811HP_ENG_MFL 180 7 19 07 3 04 PM Page 8 ...

Страница 9: ...ng Switch DC When you attach an Auto Iris lens requir ing the DC control signal please put this switch in the DC position ELC When you attach a manual or fixed lens please put this switch in the ELC position VIDEO When you attach an Auto Iris lens requiring the video control signal please put this switch in the VIDEO position 13 Line lock phase adjustment volume 14 DC iris level adjustment volume ...

Страница 10: ... and the monitor or time lapse VCR 2 Use a commercially available Certified Listed Class 2 AC 24V or DC 12V adaptor Connect an AC 24V or DC 12V power source to the POWER INPUT terminal on the back of the camera 3 Insert the plug of this power cord into a wall outlet The POWER indicator will light 1 2 3 To monitor s Video Input or Camera Input LVC SX811HP_ENG_MFL 180 7 19 07 3 04 PM Page 10 ...

Страница 11: ...on on the lens mount then carefully align the lens mount with the camera opening and turn the lens slowly to install it 3 Connect the lens plug to the lens iris output connector LENS on the back of the camera When using lenses from other makers the plug shape may not correspond to the terminal on the camera In such a case remove the original plug and using a soldering iron connect a lens iris plug...

Страница 12: ... 4 Drive Ground Rewire the lens iris plug 1 Cut off the plug of the lens cable cut off approximately 8mm of the insulation and then strip approximately 2mm of the ends of the cable sheaths 2 Solder the ends of the cable wires to the ends of the pins and then attach the cover of the lens iris plug 8mm 2mm LVC SX811HP_ENG_MFL 180 7 19 07 3 04 PM Page 12 ...

Страница 13: ... DC type coil lens Set the ALC Lens Setting Switch to the DC position CAUTION Depending on the type of lens used the lens may not perform properly In such a case adjust the LEVEL volume on the lens casing to correct ELC type auto iris lens Use a manual or fixed iris lens Set the ALC Lens Setting Switch to the ELC position LVC SX811HP_ENG_MFL 180 7 19 07 3 04 PM Page 13 ...

Страница 14: ... the ALC Lens Setting Switch to the VIDEO position CAUTION Be cautions not to use Auto Iris Lens with over 35mA Notes Set the ALC and LEVEL controls on the lens to adjust the iris Normally the ALC volume should be turned all the way to Av Average Depending on the type of lens used the lens may not perform properly In such a case adjust the LEVEL vol ume on the lens casing to correct ALC LEVEL ALC ...

Страница 15: ...10dB Max Sets to this position when strong light comes in behind the target Normal position Shutter speed is fixed NTSC 1 100 sec PAL 1 120 sec Shutter speed is auto Line lock Synchronization mode Internal Synchronization mode 1 White Balance 2 AGC Auto Gain Control 3 BLC Back Light Compensation 4 FL Flickerless 5 SYNC Synchronization Factory Setting LVC SX811HP_ENG_MFL 180 7 19 07 3 04 PM Page 15...

Страница 16: ... func tion may be switch again and again In this case use the manual mode or Night Lock function Night Lock function in Auto mode The D N Auto function is fixed to night mode Close the connected External S W for this funciton Note If you disconnet the external S W from the D N terminal the D N function is set to auto mode Open Open External S W Open Close External S W LVC SX811HP_ENG_MFL 180 7 19 ...

Страница 17: ...al S W the D N funciton is set to Day mode Night function When you close the external S W the D N funciton is set to night mode Note When you switching the D N function noise may appears on the screen while changing filter Open Close External S W Close Close External S W LVC SX811HP_ENG_MFL 180 7 19 07 3 04 PM Page 17 ...

Страница 18: ...thin the range approximately from 90o C to 90o C Switch the display on the monitor from camera1 to camera2 Adjust the PHASE volume on camera2 until the vertical jump of the image stops If more than two cameras are used please repeat this procedure for all the cameras If you can t adjust vertical sync phase please exchange the polarity of input terminal Camera switcher Monitor Vertical phase 18 LVC...

Страница 19: ...g ring 2 Turn the flange back adjusting ring to obtain a focused point while watching the monitor screen 3 Tighten the flange back fixing screw on the flange back adjusting ring Caution Tightening the screw by force will cause damage to the screw or deviation of focus Note The object may be out of focus when using a source of near infrared light than using the visible light flange back fixing scre...

Страница 20: ...ld always reuse the screws that have been removed Notes If using a camera mounting bracket select a location that is strong enough to bear the full weight of the camera and the mounting bracket for long periods and install the camera and mounting bracket securely The camera has not been evaluated for wall or ceiling mounting LVC SX811HP_ENG_MFL 180 7 19 07 3 04 PM Page 20 ...

Страница 21: ...ss Digital Signal Process Scanning System 2 1 Interlace Sync System Internal External Line lock Scanning Frequency 59 94Hz VD 50Hz VD Resolution 520Lines S N Ratio More than 50 dB Standard Illuminance 2000Lux 3200 K Sensitivity 1 3 Output 0 4Lux F1 0 0Lux Infrared ON Night Mode Video Output Signal 1Vp p Composite 75Ω Day Night Auto Manual EXT Back Light Manual ON OFF with DIP Switch Specifications...

Страница 22: ...alance Hold Exposure Automatic control with DC Iris meter Video Iris meter Auto Electronic Shutter Max 1 100000 Power Source DC 12V 10 AC 24V 10 Power Consumption 5 W Max Operation Temp 10o C 50o C Humidity 0 RH 60 RH Storage Temp 20o C 60o C Humidity 0 RH 85 RH Weight Approximately 300g Dimensions 63 H X 48 V X 114 7 D LVC SX811HP_ENG_MFL 180 7 19 07 3 04 PM Page 22 ...

Страница 23: ...P NO MFL30580180 LVC SX811HP_ENG_MFL 180 7 19 07 3 04 PM Page 23 ...