-3-
1. ADJUSTMENT PROCEDURES
To avoid possible exposure to microwave energy
leakage, adjust the door latches and interlock switches,
using the following procedure.
ONLY AUTHORIZED SERVICE PERSONNEL
SHOULD MAKE THIS ADJUSTMENT.
The Interlock Monitor and Primary Interlock Switch acts
as the final safety switch protecting the user from
microwave energy. The terminals between “COM” and
“NC” of the Interlock Monitor must close when the door
is opened. After adjusting the Interlock Monitor Switch,
make sure that it is correctly connected. See Figures 1-a
and 1-b throughout this procedure.
CHECK THE DOOR LATCH AND SWITCH
CLOSING.
NOTE: The outer cover of the microwave oven is
removed.
(1) Set the microwave oven on its side so that you can see
the latch board and the switches, as shown in
Figure 1-a.
(2) Close the door tightly and check gaps A and B to be
sure they are no more than 1/64
”
(0.5 mm). See Figure
1-b for close-up view of gaps A and B (door latches).
If all gaps are less than 1/64
”
(0.5 mm), adjustment of
the latch board may not be necessary. Go to Steps 5
and 6 to check the sequence of the switches.
NOTE: To correct sequence of the Primary Interlock
Switch, Secondary Interlock Switch and the
Interlock Monitor Switch is very important.
If any gap is larger than 1/64
”
(0.5 mm), you will need to
adjust the latch board-U, L. Go to step 3 and follow all
steps in order.
ADJUST THE LATCH AND SWITCH CLOSING
(3) Loosen the two screws holding the plastic latch board as
shown.
(4) With the oven door closed tightly, move the latch board
upward toward the top of the oven and/or away from the
door latch until the gaps are less than 1/64
”
(0.5 mm).
Hold the latch board tightly in this position until you
check the sequence of the switches in steps 5 and 6.
TEST THE LATCH AND SWITCH SEQUENCE
(5) Open the oven door slowly. Watch the door latch, the
Primary Switch. Release Rod and Lever on the switches
to make sure they are zero to the body of the switches
in the following sequence:
- Primary Interlock Switch
- Secondary Interlock Switch
- Interlock Monitor Switch
Adjust the latch board until the switches operate in this
sequence. See Steps 3 and 4.
(6) Close the oven door slowly and be sure it is tightly
closed. Watch the three switches to make sure they are
zero to the body of the switches in the following
sequence:
- Interlock Monitor Switch
- Primary Interlock Switch
- Secondary Interlock Switch
NOTE: The Interlock Monitor Switch is an added safety
check on the Primary and Secondary Interlock
Switches. If the Primary and Secondary Interlock
Switches allow the oven to operate with the door
open, the Monitor Switch will blow the fuse.
(7) When you achieve the proper sequence of switches in
Steps 5 and 6, tighten the latch board screws at that
point.
TEST THE MICROWAVE ENERGY LEAKAGE
(8) Using a survey meter, make sure the microwave energy
is below 5 mW/cm.sq.
Содержание LTM9020B
Страница 34: ... 33 13536A 13552A 13213A 13581A 14890A 14970A 14026A 15006A 268712 13581S WTP004 23506A 13720D DOOR PARTS ...
Страница 35: ... 34 WTP013 35889A 34370T 36549S 33390G WTT010 WTT020 WSZ185 33052A 33112U OVEN CAVITY PARTS ...
Страница 36: ... 35 WSZ085 56912B 55262A 44510A 43500A 466001 466003 466001 43501A LATCH BOARD PARTS ...
Страница 38: ... 37 56170D 63303A WSZ002 WTT021 WTT028 647781 65006A 63302A WTT021 BASE PLATE PARTS ...
Страница 40: ... 43 SCHEMATIC DIAGRAM OF P C B ...
Страница 41: ...PRINTED CIRCUIT BOARD 44 ...
Страница 42: ... 45 ...
Страница 43: ...P NO 3828W5S3279 Apr 2003 Printed in Korea ...