25
EXTERNAL CONTROL DEVICE SETUP
ENG
ENGLISH
Command reference list
Communication Parameters
y
Baud rate: 9600 bps (UART)
y
Data length: 8 bits
y
Parity : None
y
Stop bit: 1 bit
y
Communication code: ASCII code
y
Use a crossed (reverse) cable.
y
* Note : During USB operations such as DivX or EMF, all commands except Power(ka) and Key(mc)
are not executed and treated as NG.
COMMANd1 COMMANd2
dATA
(Hexadeci-
mal)
COMMANd1 COMMANd2
dATA
(Hexadeci-
mal)
01. Power
k
a
00 to 01
13. Treble
k
r
00 to 64
02. Aspect
Ratio
k
c
(See p.27)
14. Bass
k
s
00 to 64
03. Screen
Mute
k
d
(See p.27)
15. Balance
k
t
00 to 64
04. Volume
Mute
k
e
00 to 01
16. Colour
Temperature x
u
00 to 64
05. Volume
Control
k
f
00 to 64
17. Energy
Saving
j
q
00 to 05
06. Contrast k
g
00 to 64
18. Auto Con-
figuration
j
u
01
07. Bright-
ness
k
h
00 to 64
19. Tune
Command
m
a
(See p.29)
08. Colour
k
i
00 to 64
20. Pro-
gramme Add/
Skip
m
b
00 to 01
09. Tint
k
j
00 to 64
21. Key
m
c
Key Code
10. Sharp-
ness
k
k
00 to 64
22. Control
Back Light
m
g
00 to 64
11. OSD
Select
k
l
00 to 01
23. Input se-
lect (Main)
x
b
(See p.30)
12. Remote
Control
Lock Mode
k
m
00 to 01
(Depending on model)