Micom Circuit description
Temperature compensation from cut
JCF3
JCF4
-1
-1
-2
Undercool compensation
JCF3
JCF4
CUT
CUT
CUT
CUT
Freezer temperature
compensation
0
(Factory default)
-1
-1
-2
Remarks
2. Freezer undercool compensation circuit
►Above option circuit compensates the freezer temperature by simply cutting the circuit during the service.
2-1. Communication circuit and connecting L/wire between main PCB and display PCB
As the communication circuit, the following circuit exchanges information required between main MICOM of main PCB and
MICOM exclusively for LED for LED control of display PCB.
Sending/Receiving L/wire is required with DC12V required to operate the display PCB.
Communication error occurs when the information exchange between main MICOM of main PCB and MICOM exclusively
for LED for LED control of display PCB is disconnected for more than 30 seconds
Main PCB
Display PCB
L/Wire FD/H(4 wires)
DC 12V
GND
Receive (NO TCH condition)
Send (Error condition)
Main MICOM
MICOM exclusively
for LCD
Содержание LSXC22326
Страница 9: ...Circuit Diagram ...
Страница 25: ...Micom Circuit description ...
Страница 31: ...Compressor ...
Страница 33: ...Compressor ...
Страница 34: ...Compressor ...
Страница 35: ...Compressor ...
Страница 50: ...Troubleshooting ...
Страница 52: ...Troubleshooting ...
Страница 54: ...Troubleshooting ...
Страница 55: ...Troubleshooting 2 9 Communication Error CO E ...
Страница 73: ...FREEZER DOOR 201A 280A 405H 282G 244A 200A 131C 600A 612A 606A 241G 131D 203A 113F 113E EV EXPLODED VIEW EV ...
Страница 74: ...REFRIGERATOR DOOR EV EV 241B 241A 233A 212G 231A 231B 230A 244F 212K 212K 212J 241D 241H 241F 271D ...
Страница 78: ...August 2014 MFL62215930 ...