CHECKING FLOW CHART BY FAILURE MODE
Check the power transformer(Refer to the below)
Primary
Secondary1
Secondary2
Side
Lead color
Coil resistance
Primary 1
Black ~ white
approximately
Under100[
Ω
]
Secondary 1
yellow ~ yellow
approximately
Under 50 [
Ω
]
Secondary 2 red ~ red
approximately
Under 50 [
Ω
]
Is it OK?
Is it short?
Is it 120V AC?
Replace the thermostat.
END
2
1
No
No
Replace the power transformer
END
No
Check the Thermostat (open/short)
L1 and CN01’s RD color wire
N and CN01’s WH color wire
If it have the error, it is open state.
Yes
Yes
Power off
Dead