CONNE
CTING THE CABLE
BETWEEN INDOOR & OUTDOOR UNIT
Connec
t the cable to the
outdoor unit
A
Remov
e the control cov
er fr
om the unit by
loosening the screw
.
Connect the wir
es to the t
erminals on the
control boar
d individually.
B
Secure the cable ont
o the control boar
d with
the cord clamp
.
C
Refix the contr
ol cover t
o the original
position with the scr
ew.
D
Use a recogniz
ed circuit br
eaker 20A (
12K,18K),
25A (24K) bet
ween the pow
er source
and the unit. A disconnecting device t
o
adequately disconnect all supply lines must
be fitt
ed.
After the confirmation of the above conditions, prepare the wiring as follows:
Never
fail
to
have
an individual
power
circuit
specifically for
the air
conditioner. A
s for
the method
of wiring,
be
guided by
the cir
cuit diagr
am post
ed on
the inside
of contr
ol
cover
.
The scr
ew which fast
en the wiring
in the
casing of
electrical fittings ar
e liable
to
come
loose from vibr
ations to which
the unit
is subject
ed during
the course
of
transportation.
Check
them and
make sur
e that
they ar
e all
tightly fast
ened. (If
they
are
loose, it
may cause
burn-out of
the wires.
)
Specification of
power
source.
Confirm that
electrical capabilit
y is
sufficient.
The starting v
oltage is
maintained at
more
than 90
percent
of the
rat
ed voltage
marked
on the
name plat
e.
Confirm that
the cable
thickness is
as specified
in the
power
source
specification.
(Particularly not
e the
relation
betw
een cable
length and
thickness. (R
efer
to
page 15))
Always
install an
earth leakage
circuit
breaker
in a w
et or
moist ar
ea.
The following w
ould be
caused by v
oltage dr
op.
The means f
or disconnection fr
om a
power
supply shall
be incorpor
ated
in the fix
ed
wiring and
have
an air
gap contact
separation
of at
least 3mm
in each
active(phase
)
conductors.
Vibration of a magnetic swit
ch, which
will damage the contact point, f
use breaking,
disturbance of the
normal function of the ov
erload.
1)
2)
3)
4)
5)
6)
7)
8)
9)
Outdoor Unit
T erminal block
Over 5mm
Cover control
Connecting cable 1
Connecting cable 2
Cover Control
CAUTION
INSTALL
ATION
16
Connecting Cable 1 each (Cooling only)
Connecting cable 2 each (Heat pump only)
Содержание LSU5NP5A
Страница 4: ...4 SAFETY INSTRUCTIONS ...
Страница 19: ...MAINTENANCE 19 Do not press the mesh Caution Remove the plasma filter after 10 seconds ...
Страница 21: ...TROUBLESHOOTING 21 call call call call There is a burning smell and an abrupt sound coming from the unit ...
Страница 24: ...21 INSTALLATION Do not use sea water for this purpose windbreak so that outdoor unit ...
Страница 41: ...4 SAFETY INSTRUCTIONS ...