9-10
CHECKING FLOW CHART BY FAILURE
Door Lock System Failure,F10?
Check the operation of door
lock motor.
Press PROBE button fo 3
seconds.
and try to open the door.
Does the door open?
Yes
Go to No 2
It is normal.
Check the wiring
1
Is the Connector disconnected
or loose?
Check the following :
(1) Electric wiring of relay in
Relay PCB
(2) Electric wiring of Locking Motor and Micro
Switch
(3) Electric wiring of CN31 of Main PCB
Yes
Reconnect. If
defective
harness,
replace or fix
2
Unplug the unit
No
No
Note :
Just after self-clean start, the door lock motor
starts to rotate.
During this time if the door lock switch does
NOT operate properly after rotating twice,
then supervising circuit detects a Door Lock
failure and the F10 error code appears.
Plug in the unit
Содержание LSSG3016ST
Страница 46: ...COMPOSITION OF CONTROL 6 1 6 1 Wiring Diagram Relay PCB SMPS PCB Main system PCB ...