![LG LSFD2491 series Скачать руководство пользователя страница 65](http://html.mh-extra.com/html/lg/lsfd2491-series/lsfd2491-series_service-manual_1902241065.webp)
- 65 -
Water mode doesn't work
2
Check the voltage.
(while pushing the lever S/W)
Is voltage correct?
No
Yes
5
Explain to customer
1
Check the loose connection
Change the
PCB
3
Check the resistance value.
Is Pilot Valve resistance
360~420Ω?
No
Yes
Replace
P/ Valve
Pilot Valve
Resistance [Ω]
Pilot Valve
360~420
4
Check the resistance value.
Is Water Valve resistance
360~420Ω?
No
Yes
Replace
Water Valve
Water Valve
Resistance [Ω]
Water valve
360~420
CON2
LEVER S/W
Voltage [V]
CON2
11
th
pin ~
B(NEUTRAL)
Pushing
112~115V
Not
Pushing
0~2V
CON2
10
th
pin ~
B(NEUTRAL)
Pushing
9~12V
Not
Pushing
0~2V
Содержание LSFD2491 series
Страница 4: ... 4 2 PARTS IDENTIFICATION Ice Bin Icemaker Ice Compartment Door ...
Страница 7: ... 7 ...
Страница 26: ... 26 5 CIRCUIT DIAGRAM ...
Страница 27: ... 27 6 TROUBLESHOOTING ...
Страница 28: ... 28 ...
Страница 30: ... 30 7 3 Sub PCB ...
Страница 109: ... 109 13 DESCRIPTION OF FUNCTION CIRCUIT OF MICOM ...
Страница 110: ... 110 ...
Страница 120: ...P No MFL68744201 SEP 2014 Printed in Korea ...