CLAIMS.
CAUSES AND CHECK POINTS.
HOW TO CHECK
2. No cooling.
2) Refrigeration system is clogged.
•
Heat a clogged evaporator to
check it. As soon as the
cracking sound starts, the
evaporator will begin to
freeze.
•
The evaporator does not cool
from the beginning
(no evidence of moisture
attached).
The evaporator is the same
as before even heat is
applied.
Moisture
clogged.
No electric
power on
thermo-
stat.
Weld joint
clogged.
Drier clogging.
Foreign material clogging.
Residual moisture
in the evaporator.
Residual moisture.
Insufficient drier
capacity.
Residual moisture
in pipes.
Moisture penetration - Leave it in the air. - Moisture penetration.
into the refrigeration oil.
Caps are missed.
Air blowing.
During transportation.
During work.
Not performed.
Performed.
Too short time.
Low air pressure.
Less dry air.
Air Blowing.
Leave it in the air.
Caps are missed.
Short pipe insert.
Pipe gaps.
Too much solder.
Too large.
Damaged pipes.
Not dried in the compressor.
Elapsed more than 6 months after drying
Caps are missed.
No pressure when it is open.
During rest time.
After work.
Compressor cap is disconnected.
Foreign materials are in the pipe.
Not performed.
Too short.
Impossible moisture
confirmation.
Low air pressure.
Dry drier - Drier temperature.
Leave it in the air.
The capillary tube inserted depth. - Too much.
Capillary tube melts. - Over heat.
Clogged with foreign materials.
Reduced cross section by cutting. - Squeezed.
Desiccant powder.
Weld oxides.
Drier angle.
Check on package
condition.
Good storage after
finishing.
- 41 -
Содержание LSC27918ST
Страница 23: ... 23 ...
Страница 33: ... 33 ...
Страница 34: ... 34 ...
Страница 35: ... 35 ...
Страница 39: ...8 CIRCUIT DIAGRAM PCB ASSEMBLY S W CON10 PWB ASSEMBLY LAMP CON2 PWB ASSEMBLY LAMP CON2 39 ...
Страница 79: ...REFRIGERATOR DOOR 241H 233A 231A 241D 243B 230A 212G 241B 241C 241A 237A 241H 241H 237A 212J 244A EV 79 ...
Страница 84: ...OCTOBER 2009 MFL62215910 ...