- 59 -
TROUBLE DIAGNOSIS
CLAIMS.
CAUSES AND CHECK POINTS.
HOW TO CHECK
3. Refrigeration
is weak.
3) Cooling air leak.
4) No cooling air circulation.
Residual
frost.
No automatic defrosting.
Defrost does not return.
Bad gasket adhestion
Door sag.
Faulty fan motor.
Weak heat from heater.
Too short defrosting time.
Defrost Sensor.
- Faulty characteristics.
Seat-D (missing, location. thickness).
Structural fault.
Gasket gap.
Air inflow through the fan motor.
Bad insulation of case door.
Sheath Heater - rated.
Heater plate
Heater cord-L
Gap.
Bad attachment.
Contraction.
Bad adhesion.
Weak binding force at hinge.
Fan motor.
Door switch.
Self locked.
Wire is cut.
Bad terminal contact.
Contact distance.
Button pressure.
Melted contact.
Contact.
Poor door
attachment.
Door liner
(dimension).
Contraction inner
liner.
Misalignment.
Bad terminal
connection.
Adiabatics liquid
leak.
Faults.
Refrigerator and freezer switch reversed.
Button is not pressed.
No contact to drain.
Loosened stopper cord.
Not touching the
evaporator pipe.
Location of assembly
(top and middle).
■
Check the fan motor
conduction: OK.
No conduction: NG.
Содержание LSC 26945SW
Страница 33: ...1 8 Stepping motor operation circuit 1 LSC26945TT LSC26945SW EXPLANATION FOR MICOM CIRCUIT 33 ...
Страница 43: ...2 2 Parts list 1 LSC26945TT LSC26945SW EXPLANATION FOR MICOM CIRCUIT 43 ...
Страница 44: ...EXPLANATION FOR MICOM CIRCUIT 44 ...
Страница 45: ...2 3 DISPLAY ASSEMBLY part diagram 1 LSC26945TT LSC26945SW EXPLANATION FOR MICOM CIRCUIT 45 ...
Страница 46: ...2 4 DISPLAY circuit diagram 1 LSC26945TT LSC26945SW 46 ...
Страница 47: ...3 PWB Circuit Diagram may vary according to model 1 LSC26945TT LSC26945SW EXPLANATION FOR MICOM CIRCUIT 47 ...
Страница 48: ...EXPLANATION FOR MICOM CIRCUIT 48 ...
Страница 55: ... 1 LSC26945TT LSC26945SW CIRCUIT 55 3854JD1125C ...
Страница 100: ...FREEZER DOOR PART LSC26945TT LSC26945SW Optional part EXPLODED VIEW 100 202A 205A 200A 210A 203A 201A 210B 210C 210B ...
Страница 107: ...P No 3828JD8797F JUN 2006 Printed in Korea ...